CHChih-Ying Huang

Chih-Ying Huang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chih-Ying Huang has a total of 1 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Effects of Adhesive and Bonding Length on the Strain Transfer of Optical Fiber Sensors

    by Shiuh-Chuan Her, Chih-Ying Huang

    Optical fiber sensors have been extensively adapted as structural health monitoring devices. Due to the existence of the adhesive layer, a portion of the strain is absorbed by the adhesive. As a result, the structural strain sensed by the optical fiber is underestimated and required to be corrected. An analytical solution is presented through which it is possible to establish the relationship between the strains in the host structure and the surface bonded optical fiber sensor. Experimental measurements based on the Mach–Zehnder interferometric technique were performed to validate the theoretical prediction and reveal the differential strains between the optical fiber strain sensor and test specimen. Parametric studies show that the percentage of the strain in the test specimen actually transferred to the optical fiber is dependent on the bonding length of the optical fiber and the adhesive. The strain transfer is increasing from 56% to 82% as the bonding length increases from 5 cm to 12 cm with the epoxy adhesive. The general trend of the strain transfer obtained from both experimental tests and theoretical predictions shows that the longer the bonding length and the stiffer the adhesive, the more strain is transferred to the optical fiber.


  • Open Access

    Thermal Strain Analysis of Optic Fiber Sensors

    by Shiuh-Chuan Her, Chih-Ying Huang

    An optical fiber sensor surface bonded onto a host structure and subjected to a temperature change is analytically studied in this work. The analysis is developed in order to assess the thermal behavior of an optical fiber sensor designed for measuring the strain in the host structure. For a surface bonded optical fiber sensor, the measuring sensitivity is strongly dependent on the bonding characteristics which include the protective coating, adhesive layer and the bonding length. Thermal stresses can be generated due to a mismatch of thermal expansion coefficients between the optical fiber and host structure. The optical fiber thermal strain induced by the host structure is transferred via the adhesive layer and protective coating. In this investigation, an analytical expression of the thermal strain and stress in the optical fiber is presented. The theoretical predictions are validated using the finite element method. Numerical results show that the thermal strain and stress are linearly dependent on the difference in thermal expansion coefficients between the optical fiber and host structure and independent of the thermal expansion coefficients of the adhesive and coating.


  • Open Access

    Effect of Coating on the Strain Transfer of Optical Fiber Sensors

    by Shiuh-Chuan Her, Chih-Ying Huang

    Optical fiber strain sensors with light weight, small dimensions and immunity to electromagnetic interference are widely used in structural health monitoring devices. As a sensor, it is expected that the strains between the optical fiber and host structure are the same. However, due to the shear deformation of the protective coating, the optical fiber strain is different from that of host structure. To improve the measurement accuracy, the strain measured by the optical fiber needs to be modified to reflect the influence of the coating. In this investigation, a theoretical model of the strain transferred from the host material to the optical fiber is developed to evaluate the interaction between the host material and coating. The theoretical predictions are validated with a numerical analysis using the finite element method. Experimental tests are performed to reveal the differential strains between the optical fiber strain sensor and test specimen. The Mach-Zehnder interferometric type fiber-optic sensor is adopted to measure the strain. Experimental results show that the strain measured at the optical fiber is lower than the true strain in the test specimen. The percentage of strain in the test specimen actually transferred to the optical fiber is dependent on the bonded length of the optical fiber and the protective coating. The general trend of the strain transformation obtained from both experimental tests and theoretical predictions shows that the longer the bonded length and the stiffer the coating the more strain is transferred to the optical fiber.