Eun Sun Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Eun Sun Lee has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Chi-Seung Lee
Pusan National University
1 shared publication - Jin-Young Heo
S-ONE Bio CORP., Busan 49241, Korea
1 shared publication - Sang-Eui Lee
Department of Mechatronics Convergence Engineering, Changwon National University, Changwon 51140, Republic of Korea
1 shared publication - Tae Sik Goh
Department of Orthopaedic Surgery, Pusan National University Hospital, Busan, Republic of Korea
1 shared publication - Yoon-Jin Kim
S-ONE Bio CORP., Busan 49241, Korea
1 shared publication - Yun Hak Kim
Department of Anatomy, School of Medicine, Pusan National University, Yangsan, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 11 February 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (3) , 586
Experimental Evaluation of Screw Pullout Force and Adjacent Bone Damage According to Pedicle Screw Design Parameters in Normal and Osteoporotic Bones
This paper proposes an optimum design of the pedicle screw with respect to bone density and variables of the screw design. First, pedicle screws are designed and manufactured with design variables including the core diameter and conical angle that affect the pullout force of the pedicle screw. Variables of bone density are also classified into two groups, namely grade 10 (0.16 g/cc) with osteoporotic bone density and grade 20 (0.32 g/cc) with normal bone density. The effect of each parameter on the pullout force and relationship between the pullout force and screw designs are investigated. Furthermore, bone damage after fixation failure or insertion in the patient body is considered separately from the pullout strength. Therefore, cross sectional images of the artificial bone are observed to analyze the degree of damage after the pullout test of the pedicle screw by using micro-CT (computed tomography). The region and degree of bone damage are quantitatively analyzed. The effects of the core diameter and conical angle of the pedicle screw on the pulling force, bone damage, and fracture behavior are analyzed via the aforementioned experiments and analysis. An optimal pedicle screw design is suggested based on the experimental results.
- 11 February 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (3) , 586
Open AccessExperimental Evaluation of Screw Pullout Force and Adjacent Bone Damage According to Pedicle Screw Design Parameters in Normal and Osteoporotic Bones
This paper proposes an optimum design of the pedicle screw with respect to bone density and variables of the screw design. First, pedicle screws are designed and manufactured with design variables including the core diameter and conical angle that affect the pullout force of the pedicle screw. Variables of bone density are also classified into two groups, namely grade 10 (0.16 g/cc) with osteoporotic bone density and grade 20 (0.32 g/cc) with normal bone density. The effect of each parameter on the pullout force and relationship between the pullout force and screw designs are investigated. Furthermore, bone damage after fixation failure or insertion in the patient body is considered separately from the pullout strength. Therefore, cross sectional images of the artificial bone are observed to analyze the degree of damage after the pullout test of the pedicle screw by using micro-CT (computed tomography). The region and degree of bone damage are quantitatively analyzed. The effects of the core diameter and conical angle of the pedicle screw on the pulling force, bone damage, and fracture behavior are analyzed via the aforementioned experiments and analysis. An optimal pedicle screw design is suggested based on the experimental results.