Wang Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wang Jiang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Jiping Lu
State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Shapingba District, Chongqing 400044, China
1 shared publication - Jiping Lu
State Key Laboratory of Power Transmission Equipment & System Security and New Technology, College of Electrical Engineering, Chongqing University, Chongqing, China
1 shared publication - Ya Zhu
Maintenance Branch of Chongqing Electric Power Company of (State Grid), No. 12 Zhongshan Road, Yuzhong District, Chongqing 400015, China
1 shared publication - Zheng Li
School of Automation, Chengdu University of Information Technology, Chengdu 610025, China
1 shared publication
Latest Publications
- Open Access
Ground-Fault Characteristic Analysis of Grid-Connected Photovoltaic Stations with Neutral Grounding Resistance
A centralized grid-connected photovoltaic (PV) station is a widely adopted method of neutral grounding using resistance, which can potentially make pre-existing protection systems invalid and threaten the safety of power grids. Therefore, studying the fault characteristics of grid-connected PV systems and their impact on power-grid protection is of great importance. Based on an analysis of the grid structure of a grid-connected PV system and of the low-voltage ride-through control characteristics of a photovoltaic power supply, this paper proposes a short-circuit calculation model and a fault-calculation method for this kind of system. With respect to the change of system parameters, particularly the resistance connected to the neutral point, and the possible impact on protective actions, this paper achieves the general rule of short-circuit current characteristics through a simulation, which provides a reference for devising protection configurations.
Open AccessGround-Fault Characteristic Analysis of Grid-Connected Photovoltaic Stations with Neutral Grounding Resistance
A centralized grid-connected photovoltaic (PV) station is a widely adopted method of neutral grounding using resistance, which can potentially make pre-existing protection systems invalid and threaten the safety of power grids. Therefore, studying the fault characteristics of grid-connected PV systems and their impact on power-grid protection is of great importance. Based on an analysis of the grid structure of a grid-connected PV system and of the low-voltage ride-through control characteristics of a photovoltaic power supply, this paper proposes a short-circuit calculation model and a fault-calculation method for this kind of system. With respect to the change of system parameters, particularly the resistance connected to the neutral point, and the possible impact on protective actions, this paper achieves the general rule of short-circuit current characteristics through a simulation, which provides a reference for devising protection configurations.
- Open Access
- 22 October 2015
- Published by University of Slavonski Brod in Tehnicki vjesnik - Technical Gazette
- Vol. 22 (5) , 1199-1205
Fuzzy logic system for frequency stability analysis of wind farm integrated power systems
This paper introduces a fuzzy logic system to analyse the frequency response of wind farms composed of variable speed wind turbine generators (WTGs). WTGs can provide frequency support by using their energy reserves. However, the...
- 22 October 2015
- Published by University of Slavonski Brod in Tehnicki vjesnik - Technical Gazette
- Vol. 22 (5) , 1199-1205
Open AccessFuzzy logic system for frequency stability analysis of wind farm integrated power systems
This paper introduces a fuzzy logic system to analyse the frequency response of wind farms composed of variable speed wind turbine generators (WTGs). WTGs can provide frequency support by using their energy reserves. However, the...