Aurora Soler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Aurora Soler has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Juan Antonio Conesa
Department of Chemical Engineering, University of Alicante, P.O. Box 99, E-03080 Alicante, Spain
2 shared publications - Nuria Ortuño
University Institute of Water and Environmental Sciences, University of Alicante, 03690 Alicante, Spain
2 shared publications
Latest Publications
- 1 November 2018
- Published by Elsevier in Chemosphere
- Vol. 211, 294-301
Inhibiting fly ash reactivity by adding N- and S- containing compounds
- 1 November 2018
- Published by Elsevier in Chemosphere
- Vol. 211, 294-301
Inhibiting fly ash reactivity by adding N- and S- containing compounds
- Open Access
Application of Subcritical Water to Dechlorinate Polyvinyl Chloride Electric Wires
Polyvinyl chloride (PVC) electric wires were subjected to dechlorination in subcritical water at three different temperatures in a high-pressure reactor. About 2.09, 73.08, and 95.96 wt % of chlorine in PVC wires was removed during dechlorination at 200 °C, 250 °C, and 300 °C, respectively. The solid residues were analyzed and characterized by thermogravimetry, at three different heating rates (5 °C, 10 °C, and 20 °C/min) in inert and oxidizing atmosphere. With the purpose of studying the emission of chlorinated pollutants, pyrolysis experiments at 850 °C were also performed in a laboratory-scale reactor with the dechlorinated materials, as well as with the original PVC electric wire. Polycyclic aromatic hydrocarbons (PAH) formation increased, but chlorobenzenes (ClBz) and chlorophenols (ClPh) formation decreased as the temperature of dechlorination increased; naphthalene was the most abundant PAH and monochlorobenzene and monochlorinated phenols (3-+4-) were the most abundant chlorinated compounds.
Open AccessApplication of Subcritical Water to Dechlorinate Polyvinyl Chloride Electric Wires
Polyvinyl chloride (PVC) electric wires were subjected to dechlorination in subcritical water at three different temperatures in a high-pressure reactor. About 2.09, 73.08, and 95.96 wt % of chlorine in PVC wires was removed during dechlorination at 200 °C, 250 °C, and 300 °C, respectively. The solid residues were analyzed and characterized by thermogravimetry, at three different heating rates (5 °C, 10 °C, and 20 °C/min) in inert and oxidizing atmosphere. With the purpose of studying the emission of chlorinated pollutants, pyrolysis experiments at 850 °C were also performed in a laboratory-scale reactor with the dechlorinated materials, as well as with the original PVC electric wire. Polycyclic aromatic hydrocarbons (PAH) formation increased, but chlorobenzenes (ClBz) and chlorophenols (ClPh) formation decreased as the temperature of dechlorination increased; naphthalene was the most abundant PAH and monochlorobenzene and monochlorinated phenols (3-+4-) were the most abundant chlorinated compounds.