Fangcheng Lv
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Fangcheng Lv has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Jianghai Geng
Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power University, Baoding 071003, China
3 shared publications - Xiaozhou Fan
Hebei Provincial Key Laboratory of Power Transmission and Transformation Equipment Safety Defense, North China Electric Power University, Baoding 071003, China
3 shared publications - Bowen Jiang
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Baoding 071003, China
2 shared publications - Bowen Liu
Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defence, North China Electric Power University, Baoding 071003, China
2 shared publications - Qi Ou
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206, China
2 shared publications - Shenghui Wang
North China Electric Power University
2 shared publications
Latest Publications
- Open Access
Investigating Aging Characteristics of Oil-Immersed Power Transformers’ Insulation in Electrical–Thermal–Mechanical Combined Conditions
The condition and health of large oil-immersed power transformers’ insulation have a direct impact on the safety and stability of the power grid. Therefore, it is crucial to investigate the aging characteristics of oil–paper insulation in power transformers. In this study, we developed a computational model for reclosing current calculation and multiphysics coupling models for magnetic-circuit-force, electrostatic field, and temperature field simulations. The calculated aging resulted in a mechanical stress of 8.71 MPa, an electric field strength of 2.26 × 106 V/m, and a temperature of 113.7 °C. We conducted combined electrical–thermal–mechanical aging tests on the oil–paper insulation and measured various insulating paper performance parameters at different aging stages. Our study revealed that both the mechanical and electrical properties of the insulating paper deteriorated in both aging groups. However, the changes were more pronounced in the electrical–thermal–mechanical aging group compared to the electrical–thermal aging group, indicating that mechanical stress accelerated the aging process of the insulating paper. In the early stages of aging, the rate of performance changes in the electrical–thermal aging group was similar to that in the electrical–thermal–mechanical aging group. However, as the aging time increased, the degradation of performance induced by mechanical aging became more significant. This suggests that the insulating paper’s resistance to mechanical damage, specifically short-circuit resistance, noticeably decreased after prolonged aging.
Open AccessInvestigating Aging Characteristics of Oil-Immersed Power Transformers’ Insulation in Electrical–Thermal–Mechanical Combined Conditions
The condition and health of large oil-immersed power transformers’ insulation have a direct impact on the safety and stability of the power grid. Therefore, it is crucial to investigate the aging characteristics of oil–paper insulation in power transformers. In this study, we developed a computational model for reclosing current calculation and multiphysics coupling models for magnetic-circuit-force, electrostatic field, and temperature field simulations. The calculated aging resulted in a mechanical stress of 8.71 MPa, an electric field strength of 2.26 × 106 V/m, and a temperature of 113.7 °C. We conducted combined electrical–thermal–mechanical aging tests on the oil–paper insulation and measured various insulating paper performance parameters at different aging stages. Our study revealed that both the mechanical and electrical properties of the insulating paper deteriorated in both aging groups. However, the changes were more pronounced in the electrical–thermal–mechanical aging group compared to the electrical–thermal aging group, indicating that mechanical stress accelerated the aging process of the insulating paper. In the early stages of aging, the rate of performance changes in the electrical–thermal aging group was similar to that in the electrical–thermal–mechanical aging group. However, as the aging time increased, the degradation of performance induced by mechanical aging became more significant. This suggests that the insulating paper’s resistance to mechanical damage, specifically short-circuit resistance, noticeably decreased after prolonged aging.
- Open Access
- 18 July 2023
- Published by MDPI AG in Chemosensors
- Vol. 11 (7) , 402
A DFT Study on Adsorption of SF6 Decomposition Products on Zr-MOF-808
Identifying the main byproducts of SF6 decomposition proves to be an effective strategy for determining the nature and severity of internal discharge faults in gas-insulated switchgears (GISs). In this research, it was suggested to utilize the coordination polymer Zr-MOF-808 as a sensor for the main byproducts of SF6 decomposition. This study examined the adsorption of SF6 and its main decomposition products (CF4, CS2, SO2, SO2F2, and SOF2) on Zr-MOF-808, utilizing Gaussian16 simulation software through a method anchored on quantum chemistry. Adsorption parameters were calculated and analyzed, including binding energy, charge transfer, adsorption distance, along with variations in bond length, bond angle, density of states, and frontier orbital of gas molecules. Our research indicated that the Zr-MOF-808 cluster demonstrated varying degrees of chemical adsorption for the six gases, leading to differential conductivity changes in each system following adsorption. Consequently, the detection of resistance value alterations in the materials would allow for the identification of the gas products.
- 18 July 2023
- Published by MDPI AG in Chemosensors
- Vol. 11 (7) , 402
Open AccessA DFT Study on Adsorption of SF6 Decomposition Products on Zr-MOF-808
Identifying the main byproducts of SF6 decomposition proves to be an effective strategy for determining the nature and severity of internal discharge faults in gas-insulated switchgears (GISs). In this research, it was suggested to utilize the coordination polymer Zr-MOF-808 as a sensor for the main byproducts of SF6 decomposition. This study examined the adsorption of SF6 and its main decomposition products (CF4, CS2, SO2, SO2F2, and SOF2) on Zr-MOF-808, utilizing Gaussian16 simulation software through a method anchored on quantum chemistry. Adsorption parameters were calculated and analyzed, including binding energy, charge transfer, adsorption distance, along with variations in bond length, bond angle, density of states, and frontier orbital of gas molecules. Our research indicated that the Zr-MOF-808 cluster demonstrated varying degrees of chemical adsorption for the six gases, leading to differential conductivity changes in each system following adsorption. Consequently, the detection of resistance value alterations in the materials would allow for the identification of the gas products.
- Open Access
- 23 May 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (11) , 1705
Theoretical Study on Adsorption Behavior of SF6 Decomposition Components on Mg-MOF-74
SF6 gas is an arc extinguishing medium that is widely used in gas insulated switchgear (GIS). When insulation failure occurs in GIS, it leads to the decomposition of SF6 in partial discharge (PD) and other environments. The detection of the main decomposition components of SF6 is an effective method to diagnose the type and degree of discharge fault. In this paper, Mg-MOF-74 is proposed as a gas sensing nanomaterial for detecting the main decomposition components of SF6. The adsorption of SF6, CF4, CS2, H2S, SO2, SO2F2 and SOF2 on Mg-MOF-74 was calculated by Gaussian16 simulation software based on density functional theory. The analysis includes parameters of the adsorption process such as binding energy, charge transfer, and adsorption distance, as well as the change in bond length, bond angle, density of states, and frontier orbital of the gas molecules. The results show that Mg-MOF-74 has different degrees of adsorption for seven gases, and chemical adsorption will lead to changes in the conductivity of the system; therefore, it can be used as a gas sensing material for the preparation of SF6 decomposition component gas sensors.
- 23 May 2023
- Published by MDPI AG in Nanomaterials
- Vol. 13 (11) , 1705
Open AccessTheoretical Study on Adsorption Behavior of SF6 Decomposition Components on Mg-MOF-74
SF6 gas is an arc extinguishing medium that is widely used in gas insulated switchgear (GIS). When insulation failure occurs in GIS, it leads to the decomposition of SF6 in partial discharge (PD) and other environments. The detection of the main decomposition components of SF6 is an effective method to diagnose the type and degree of discharge fault. In this paper, Mg-MOF-74 is proposed as a gas sensing nanomaterial for detecting the main decomposition components of SF6. The adsorption of SF6, CF4, CS2, H2S, SO2, SO2F2 and SOF2 on Mg-MOF-74 was calculated by Gaussian16 simulation software based on density functional theory. The analysis includes parameters of the adsorption process such as binding energy, charge transfer, and adsorption distance, as well as the change in bond length, bond angle, density of states, and frontier orbital of the gas molecules. The results show that Mg-MOF-74 has different degrees of adsorption for seven gases, and chemical adsorption will lead to changes in the conductivity of the system; therefore, it can be used as a gas sensing material for the preparation of SF6 decomposition component gas sensors.
- Open Access
Molecular Dynamics Study of the Influence of Nano SiO2 on the Thermodynamic Properties of PMIA Composites
The poly-m-phenyleneisophthalamide (PMIA) is widely used in the electrical field due to its numerous favorable characteristics, but its poor thermal conductivity limits its application. In this study, PMIA was modified with nano-silica (SiO2) to improve its thermal and mechanical properties. Using iso-phthalic acid and m-phenylenediamine as monomers, the changes in the thermodynamic properties and microstructure parameters of SiO2-modified PMIA were analyzed using molecular dynamics before and after modification in the temperature range of 250~450 K. It was found that adding SiO2 improves the Young’s modulus and Shear modulus of PMIA, and the mechanical properties of PMIA, and SiO2/PMIA composites deteriorate with increasing temperature, but the mechanical properties of SiO2/PMIA composites are always better than those of pure PMIA in the temperature range of electrical equipment. Meanwhile, after doping SiO2 with the radius of 8 Å, the glass transition temperature of PMIA increases by 27.11 K, and its thermal conductivity increases from 0.249 W m−1 K−1 to 0.396 W m−1 K−1. When SiO2 is added to PMIA, the thermal expansion coefficient of PMIA will decrease in both glass and rubber states, and its thermal stability will improve. In terms of microstructure parameters, the free volume distribution of the SiO2/PMIA model is less easily dispersed than that of the PMIA model, indicating that the addition of SiO2 can improve the related properties of PMIA by hindering the movement of molecular chains.
Open AccessMolecular Dynamics Study of the Influence of Nano SiO2 on the Thermodynamic Properties of PMIA Composites
The poly-m-phenyleneisophthalamide (PMIA) is widely used in the electrical field due to its numerous favorable characteristics, but its poor thermal conductivity limits its application. In this study, PMIA was modified with nano-silica (SiO2) to improve its thermal and mechanical properties. Using iso-phthalic acid and m-phenylenediamine as monomers, the changes in the thermodynamic properties and microstructure parameters of SiO2-modified PMIA were analyzed using molecular dynamics before and after modification in the temperature range of 250~450 K. It was found that adding SiO2 improves the Young’s modulus and Shear modulus of PMIA, and the mechanical properties of PMIA, and SiO2/PMIA composites deteriorate with increasing temperature, but the mechanical properties of SiO2/PMIA composites are always better than those of pure PMIA in the temperature range of electrical equipment. Meanwhile, after doping SiO2 with the radius of 8 Å, the glass transition temperature of PMIA increases by 27.11 K, and its thermal conductivity increases from 0.249 W m−1 K−1 to 0.396 W m−1 K−1. When SiO2 is added to PMIA, the thermal expansion coefficient of PMIA will decrease in both glass and rubber states, and its thermal stability will improve. In terms of microstructure parameters, the free volume distribution of the SiO2/PMIA model is less easily dispersed than that of the PMIA model, indicating that the addition of SiO2 can improve the related properties of PMIA by hindering the movement of molecular chains.
- Open Access
Effect of Particle Trap on Motion Characteristics of Metal Particles in AC GILs and Parameter Optimization
Metal particle contamination is an important reason for insulation failure of gas-insulated transmission lines (GILs). Particle trap is the common method for particle suppression. At present, research on the motion characteristics of metal particles near a particle trap and the optimization of trap parameters under AC voltage is insufficient. Based on that, firstly, a dynamic model of metal particles under AC voltage was established, and the motion characteristics of particles in front of the trap were studied, combined with experiments. Then, the influence of trap parameters on the capture effect was analyzed, and the optimization of the trap was realized by simulation. The results showed that, under AC voltage, the randomness of metal particle movement was strong, and the activity was low. The particles mainly moved away from the trap. Among the particles moving towards the trap, some stayed in front of the trap, and some fell into the trap from above. The thickness and height of the trap were the key parameters affecting the capture effect, and with the increase in height and thickness, the capture rate showed a trend of increasing first and then decreasing. The above conclusions can provide a reference for the optimization of a metal particle trap under AC voltage in engineering.
Open AccessEffect of Particle Trap on Motion Characteristics of Metal Particles in AC GILs and Parameter Optimization
Metal particle contamination is an important reason for insulation failure of gas-insulated transmission lines (GILs). Particle trap is the common method for particle suppression. At present, research on the motion characteristics of metal particles near a particle trap and the optimization of trap parameters under AC voltage is insufficient. Based on that, firstly, a dynamic model of metal particles under AC voltage was established, and the motion characteristics of particles in front of the trap were studied, combined with experiments. Then, the influence of trap parameters on the capture effect was analyzed, and the optimization of the trap was realized by simulation. The results showed that, under AC voltage, the randomness of metal particle movement was strong, and the activity was low. The particles mainly moved away from the trap. Among the particles moving towards the trap, some stayed in front of the trap, and some fell into the trap from above. The thickness and height of the trap were the key parameters affecting the capture effect, and with the increase in height and thickness, the capture rate showed a trend of increasing first and then decreasing. The above conclusions can provide a reference for the optimization of a metal particle trap under AC voltage in engineering.
- Open Access
- 23 February 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (5) , 748
Insulation Performance and Simulation Analysis of SiO2-Aramid Paper under High-Voltage Bushing
The long-term safe and stable operation of oil-impregnated paper (OIP) bushings is of great significance to the operation of power systems. With the growth of OIP bushing, its internal insulation will gradually decay. Aramid insulation paper has excellent thermal aging characteristics and its insulation performance can be improved by using nano-modification technology. In this paper, the nano-SiO2 particles were used as the modified additives, and the modified aramid insulation paper was prepared through four steps: ultrasonic stirring, fiber dissociation, paper sample copying and superheated calendering. The microscopic physical morphology and chemical components of the insulation specimens before and after modification were analyzed by atomic force microscopy (AFM), scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS), and an OIP bushing model based on the modified aramid insulation paper was constructed and its electric field distribution was analyzed. The simulation results show that the use of SiO2-modified aramid insulation paper can improve the electric field distribution of OIP bushings and increase the operating life of power transformers.
- 23 February 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (5) , 748
Open AccessInsulation Performance and Simulation Analysis of SiO2-Aramid Paper under High-Voltage Bushing
The long-term safe and stable operation of oil-impregnated paper (OIP) bushings is of great significance to the operation of power systems. With the growth of OIP bushing, its internal insulation will gradually decay. Aramid insulation paper has excellent thermal aging characteristics and its insulation performance can be improved by using nano-modification technology. In this paper, the nano-SiO2 particles were used as the modified additives, and the modified aramid insulation paper was prepared through four steps: ultrasonic stirring, fiber dissociation, paper sample copying and superheated calendering. The microscopic physical morphology and chemical components of the insulation specimens before and after modification were analyzed by atomic force microscopy (AFM), scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS), and an OIP bushing model based on the modified aramid insulation paper was constructed and its electric field distribution was analyzed. The simulation results show that the use of SiO2-modified aramid insulation paper can improve the electric field distribution of OIP bushings and increase the operating life of power transformers.
- Open Access
- 27 October 2021
- Published by MDPI AG in Electronics
- Vol. 10 (21) , 2624
Research of ZnO Arrester Deterioration Mechanism Based on Electrical Performance and Micro Material Test
The traction power supply system of an Electrical Multiple Unit (EMU) often suffers from overvoltage impact. As an important protection device for on-board electrical equipment, the working environment of a roof arrester is worse than that of a power system. In recent years, the explosion failure of the roof arresters of an EMU has occurred from time to time, which seriously endangers the safe operation of high-speed railways. In this paper, the electrical performance test and material micro test of roof arrester in three states of normal, defect, and exploded, are carried out in order to study the internal causes of roof arrester explosion and clarify its deterioration mechanism. Using the DC reference voltage test and leakage current test, the electrical performance differences of normal, defective, and exploded arresters are obtained. By studying the disassembly of an arrester, the appearance characteristics of arrester varistor in three states are obtained. The micro morphology and chemical elements of the varistor are analyzed by Scanning Electron Microscope and Energy Dispersive Spectrometer. The deterioration mechanism of the arrester varistor is then revealed, and preventive measures for the explosion failure of the roof arrester are put forward. The obtained results show that, during the long-term operation of the roof arrester of an EMU, the varistor may be damp, and therefore the aluminum electrode layer and side insulation layer of the varistor may deteriorate. After the deterioration of the aluminum electrode layer, the content of the O element increases, and multiple film structures are formed on the surface. After the deterioration of the side insulating layer, the content of the O element increases, and the surface becomes uneven. Improving the sealing performance requirements of the roof arrester and optimizing the maintenance process can reduce its explosion failure.
- 27 October 2021
- Published by MDPI AG in Electronics
- Vol. 10 (21) , 2624
Open AccessResearch of ZnO Arrester Deterioration Mechanism Based on Electrical Performance and Micro Material Test
The traction power supply system of an Electrical Multiple Unit (EMU) often suffers from overvoltage impact. As an important protection device for on-board electrical equipment, the working environment of a roof arrester is worse than that of a power system. In recent years, the explosion failure of the roof arresters of an EMU has occurred from time to time, which seriously endangers the safe operation of high-speed railways. In this paper, the electrical performance test and material micro test of roof arrester in three states of normal, defect, and exploded, are carried out in order to study the internal causes of roof arrester explosion and clarify its deterioration mechanism. Using the DC reference voltage test and leakage current test, the electrical performance differences of normal, defective, and exploded arresters are obtained. By studying the disassembly of an arrester, the appearance characteristics of arrester varistor in three states are obtained. The micro morphology and chemical elements of the varistor are analyzed by Scanning Electron Microscope and Energy Dispersive Spectrometer. The deterioration mechanism of the arrester varistor is then revealed, and preventive measures for the explosion failure of the roof arrester are put forward. The obtained results show that, during the long-term operation of the roof arrester of an EMU, the varistor may be damp, and therefore the aluminum electrode layer and side insulation layer of the varistor may deteriorate. After the deterioration of the aluminum electrode layer, the content of the O element increases, and multiple film structures are formed on the surface. After the deterioration of the side insulating layer, the content of the O element increases, and the surface becomes uneven. Improving the sealing performance requirements of the roof arrester and optimizing the maintenance process can reduce its explosion failure.
- Open Access
Alternating Current Discharge Characteristics and Simulation Analysis of Rod-Plane Short Air Gaps under Salt Fog Conditions
In this paper, smog meteorological conditions in the natural environment is simulated by the salt fog method. The study of the alternating current (AC) discharge characteristics of rod-plane short air gaps in salt fog environments has important guiding significance for how to strengthen the external insulation strength of ultra-high voltage (UHV) transmission lines and electrical equipment in smog environments. The rod-plane short air gap is selected as the model to simulate the extremely uneven electric field. The AC discharge test is carried out in the salt fog environment with different conductivity, and the finite element method (FEM) is used to simulate the distribution of electric field in air gap under salt fog environment conditions. The results show that under clean fog conditions the AC discharge voltage in the air gap increased by 15.1% to 35.5% compared to that under dry conditions. With the increased conductivity of salt fog, the AC discharge voltage in air gap decreased by 4.1% to 9.2% compared to that under clean fog conditions, and the reduction is within 10%. The distortion of the electric field and the adsorption of free electrons in the gap by droplets lead to the decrease of the electric field intensity in the air gap. With the increase of the conductivity, the electric field intensity in the air gap increases slightly. Meanwhile, the influence of salt fog and its conductivity on the AC discharge voltage of rod-plane short air gap is examined, becoming saturated with the increase of the gap distance and the conductivity of salt fog.
Open AccessAlternating Current Discharge Characteristics and Simulation Analysis of Rod-Plane Short Air Gaps under Salt Fog Conditions
In this paper, smog meteorological conditions in the natural environment is simulated by the salt fog method. The study of the alternating current (AC) discharge characteristics of rod-plane short air gaps in salt fog environments has important guiding significance for how to strengthen the external insulation strength of ultra-high voltage (UHV) transmission lines and electrical equipment in smog environments. The rod-plane short air gap is selected as the model to simulate the extremely uneven electric field. The AC discharge test is carried out in the salt fog environment with different conductivity, and the finite element method (FEM) is used to simulate the distribution of electric field in air gap under salt fog environment conditions. The results show that under clean fog conditions the AC discharge voltage in the air gap increased by 15.1% to 35.5% compared to that under dry conditions. With the increased conductivity of salt fog, the AC discharge voltage in air gap decreased by 4.1% to 9.2% compared to that under clean fog conditions, and the reduction is within 10%. The distortion of the electric field and the adsorption of free electrons in the gap by droplets lead to the decrease of the electric field intensity in the air gap. With the increase of the conductivity, the electric field intensity in the air gap increases slightly. Meanwhile, the influence of salt fog and its conductivity on the AC discharge voltage of rod-plane short air gap is examined, becoming saturated with the increase of the gap distance and the conductivity of salt fog.
- Open Access
Electric Field Distribution and Switching Impulse Discharge under Shield Ball Surface Scratch Defect in an UHVDC Hall
The dimension and surface state of shielding fittings in ultra high voltage direct current (UHVDC) converter station valve halls have a great influence on their surface electric field and switching impulse characteristics, which are important parameters confirming the air gap distance in the valve hall. The characteristics of impulse discharge under different lengths, dent degrees and burrs around the scratches of Φ1.3 m shield balls with a 2 m sphere-plane gap length were tested, in the UHVDC testing base of the Hebei Electric Power Research Institute. The discharge characteristics under the influence of the surface scratches of the shield ball were obtained. The results demonstrate that the discharge voltage of sphere-plane gap decreases obviously when there are unpolished scratches on the surface of the shield ball. However, when the scratches are polished, the discharge voltage has no significant impact. At the same time, a 1:1 full-scale impulse test model was established based on the finite element method. The electric field intensity and the space electric field distribution of the shield ball were obtained under the influence of scratches with or without burrs. The results of the simulation show that when the surface of the shield ball is smooth, the electric field distribution around it is even. The electric field intensity on the surface of the shield ball increases obviously when there are burrs around the scratches. When there is no burr around the scratches, the length and depth of the scratches have no obvious effect on its electric field distribution. Meanwhile, calculation results are consistent with test results. The results can provide an important basis for the design and optimization of shielding fittings, and technical support for its localization.
Open AccessElectric Field Distribution and Switching Impulse Discharge under Shield Ball Surface Scratch Defect in an UHVDC Hall
The dimension and surface state of shielding fittings in ultra high voltage direct current (UHVDC) converter station valve halls have a great influence on their surface electric field and switching impulse characteristics, which are important parameters confirming the air gap distance in the valve hall. The characteristics of impulse discharge under different lengths, dent degrees and burrs around the scratches of Φ1.3 m shield balls with a 2 m sphere-plane gap length were tested, in the UHVDC testing base of the Hebei Electric Power Research Institute. The discharge characteristics under the influence of the surface scratches of the shield ball were obtained. The results demonstrate that the discharge voltage of sphere-plane gap decreases obviously when there are unpolished scratches on the surface of the shield ball. However, when the scratches are polished, the discharge voltage has no significant impact. At the same time, a 1:1 full-scale impulse test model was established based on the finite element method. The electric field intensity and the space electric field distribution of the shield ball were obtained under the influence of scratches with or without burrs. The results of the simulation show that when the surface of the shield ball is smooth, the electric field distribution around it is even. The electric field intensity on the surface of the shield ball increases obviously when there are burrs around the scratches. When there is no burr around the scratches, the length and depth of the scratches have no obvious effect on its electric field distribution. Meanwhile, calculation results are consistent with test results. The results can provide an important basis for the design and optimization of shielding fittings, and technical support for its localization.
- Open Access
Experimental Study on Breakdown Characteristics of Transformer Oil Influenced by Bubbles
Bubbles will reduce the electric strength of transformer oil, and even result in the breakdown of the insulation. This paper has studied the breakdown voltages of transformer oil and oil-impregnated pressboard under alternating current (AC) and direct current (DC) voltages. In this paper, three types of electrodes were applied: cylinder-plan electrodes, sphere-plan electrodes, and cone-plan electrodes, and the breakdown voltages were measured in both no bubbles and bubbles. The sphere-sphere electrodes were used to study the breakdown voltage of the oil-impregnated pressboard. The results showed that under the influence of bubble, the breakdown voltage of the cylinder-plan electrode dropped the most, and the breakdown voltage of the cone-plan electrode dropped the least. The bubbles motion was the key factor of the breakdown. The discharge types of the oil-impregnated pressboard were different with bubbles, and under DC, the main discharge type was flashover along the oil-impregnated pressboard, while under AC, the main discharge type was breakdown through the oil-impregnated pressboard.
Open AccessExperimental Study on Breakdown Characteristics of Transformer Oil Influenced by Bubbles
Bubbles will reduce the electric strength of transformer oil, and even result in the breakdown of the insulation. This paper has studied the breakdown voltages of transformer oil and oil-impregnated pressboard under alternating current (AC) and direct current (DC) voltages. In this paper, three types of electrodes were applied: cylinder-plan electrodes, sphere-plan electrodes, and cone-plan electrodes, and the breakdown voltages were measured in both no bubbles and bubbles. The sphere-sphere electrodes were used to study the breakdown voltage of the oil-impregnated pressboard. The results showed that under the influence of bubble, the breakdown voltage of the cylinder-plan electrode dropped the most, and the breakdown voltage of the cone-plan electrode dropped the least. The bubbles motion was the key factor of the breakdown. The discharge types of the oil-impregnated pressboard were different with bubbles, and under DC, the main discharge type was flashover along the oil-impregnated pressboard, while under AC, the main discharge type was breakdown through the oil-impregnated pressboard.