GXGuobin Xu

Guobin Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Guobin Xu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Experimental Study on the Flow-Induced Motion and Hydrokinetic Energy of Two T-section Prisms in Tandem Arrangement

    by Nan Shao, Guobin Xu, Fang Liu, Xiang Yan, Xiaoqun Wang, Heng Deng, Zheng Zheng

    The advantageous performance in terms of energy conversion for the flow-induced motion (FIM) of T-section prisms has been experimentally reported recently. In order to further understand the oscillation and energy conversion of multiple T-section prisms, a series of tests of two T-section prisms arranged in tandem with five different spacing ratios (3 ≤ L/D ≤ 15) and seven load resistances (8 Ω ≤ RL ≤ 41 Ω) were conducted. The effects of the spacing ratio and load resistances on energy conversion were discussed. The main conclusions can be summarized as follows. For most tests, the amplitudes of the upstream T-section prism (UTP) and downstream T-section prism (DTP) were both lower than the amplitude of the single T-section prism (STP) due to the mutual interference of the two prisms. Because of the mutual interference, the active powers of UTP and DTP were both less than that of STP, but at some special spacing ratios or load resistances, the mutual interference benefited the energy converted by the two prisms. In the presented tests, the total optimal active power of the upstream T-section prism and downstream T-section prism (UTP + DTP) was 30.12 W, which was 1.5 times that of STP (20.12 W).


  • Open Access

    Experimental Investigation of Flow-Induced Motion and Energy Conversion of a T-Section Prism

    by Nan Shao, Jijian Lian, Guobin Xu, Fang Liu, Heng Deng, Quanchao Ren, Xiang Yan

    Flow-induced motion (FIM) performs well in energy conversion but has been barely investigated, particularly for prisms with sharp sections. Previous studies have proven that T-section prisms that undergo galloping branches with high amplitude are beneficial to energy conversions. The FIM experimental setup designed by Tianjin University (TJU) was improved to conduct a series of FIM responses and energy conversion tests on a T-section prism. Experimental results are presented and discussed, to reveal the complete FIM responses and power generation characteristics of the T-section prism under different load resistances and section aspect ratios. The main findings are summarized as follows. (1) Hard galloping (HG), soft galloping (SG), and critical galloping (CG) can be observed by varying load resistances. When the load resistances are low, HG occurs; otherwise, SG occurs. (2) In the galloping branch, the highest amplitude and the most stable oscillation cause high-quality electrical energy production by the generator. Therefore, the galloping branch is the best branch for harvesting energy. (3) In the galloping branch, as the load resistances decrease, the active power continually increases until the prism is suppressed from galloping to a vortex-induced vibration (VIV) lower branch with a maximum active power Pharn of 21.23 W and a maximum ηout of 20.2%. (4) Different section aspect ratios (α) can significantly influence the FIM responses and energy conversions of the T-section prism. For small aspect ratios, galloping is hardly observed in the complete responses, but the power generation efficiency (ηout,0.8 = 27.44%) becomes larger in the galloping branch.


  • Emergency control system based on the analytical hierarchy process and coordinated development degree model for sudden water pollution accidents in the Middle Route of the South-to-North Water Transfer Project in China

    by Yan Long, Guobin Xu, Chao Ma, Liang Chen

    Water transfer projects are important for realizing reasonable allocation of water resources, but once a water pollution accident occurs during such a project, the water environment is exposed to enormous risks. Therefore, it is critical to determine an appropriate emergency control system (ECS) for sudden water pollution accidents that occur in water transfer projects. In this study, the analytical hierarchy process (AHP) integrated with the coordinated development degree model (CDDM) was used to develop the ECS. This ECS was developed into two parts, including the emergency risk assessment and the emergency control. Feasible emergency control targets and control technology were also proposed for different sudden water pollution accidents. A demonstrative project was conducted in the Fangshui to Puyang channel, which is part of the Beijing–Shijiazhuang Emergency Water Supply Project (BSP) in the Middle Route of the South-to-North Water Transfer Project (MR-SNWTP) in China. However, we could not use an actual toxic soluble pollutant to validate our ECS, so we performed the experiment with sucrose to test the ECS based on its concentration variation. The relative error of peak sucrose concentration was less than 20 %.