MLMingyao Liu

Mingyao Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mingyao Liu has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Noninvasive Real-Time Heat Flux Measurement Method Based on T-MFBG

    by Qihui Cai, Mingyao Liu, Fengming Ai, Cong Li, Han Song

    A novel non-invasive real-time monitoring heat flux measurement with only one measuring point based on tapered metallized fiber Bragg grating (T-MFBG) has been proposed in this paper. The preparation of T-MFBG involves magnetron sputtering of the first metal layer Ti and electroplating of the second metal layer Ni. The axially increased diameter of T-MFBG broadens the spectrum with the increase of heat flux. The heat flux sensing theoretical model and working principle of T-MFBG are established to analyze the sensing characteristics of T-MFBG. Numerical analysis and theoretical calculation show that the full width at half maximum (FWHM) of T-MFBG with a length of 10 mm and a diameter of 500-550 μm increases linearly with the heat flux, and the stable transformation of heat flux and FWHM can be realized. A heat flux calibration platform was built and its feasibility was verified by simulation. The outlet pipe section heat flux of the piston pump in the hydraulic system was quantitatively measured by the T-MFBG heat flux measurement method. When monitoring the heat flux of stainless steel, the sensitivity of T-MFBG is 0.0025 pm / (W/ m2). The measurement range is 0-6795 W/ m2. The heat flux measurement method based on T-MFBG with a length of 1 cm and a maximum diameter of 1 mm has the advantages of heat flux-FWHM linear conversion, single point, real-time, small installation space, and non-invasive. It can provide theoretical guidance for the design of fiber grating heat flux sensor and facilitate the design of a series of sensors for specific measurement requirements.


  • Optimization and Invasive Monitoring for the Local Flow Velocity Maldistribution in Plate-Fin Heat Exchangers

    by Xue-Li Yang, Ming-Yao Liu, Han Song, Jun Rao, Yi-Hang Wu

    The flow maldistribution inside plate-fin heat exchangers is a decisive factor leading to the deterioration of heat transfer performance. This paper proposes the configurations of flat and curved baffles with different holes to optimize flow distribution. The invasive method using fiber Bragg grating (FBG)sensors for monitoring the local flow velocity in heat exchangers is first proposed. Multiple FBG sensors are embedded in the plate-fin core to measure the flow velocity of each channel. The effectiveness in balancing the flow velocity of flat and curved baffle configurations is compared against a header configuration without a baffle. The results indicate that adding a baffle, whether it is flat or curved, is profitable to facilitate the flow field inside the plate-fin core. Compared with no baffle configuration, the flat and curved baffle configurations achieve a decrease rate of 61% and 66% in the sum flow nonuniformity of heat exchangers. The standard deviation has been reduced by 60% and 80%, respectively. The energy loss caused by the curved plate configuration is relatively low. The embedded FBG sensors address real-time monitoring of local flow velocity in the plate-fin heat exchanger. The ameliorative baffle structure in the header and FBG sensing technology provide ideas for optimizing and monitoring the internal flow field inside plate-fin heat exchangers.


  • Open Access

    A Damage Identification Method Based on Minimum Mean Square Error Estimation for Wind Tunnel Flexible Plate Condition Monitoring System

    by Kang Yun, Mingyao Liu, Jingliang Wang, Cong Li

    In this paper, we propose a damage identification method based on minimum mean square error estimation for a wind tunnel flexible plate condition monitoring system. Critical structural members of important equipment are large in size, and the measurement systems used to monitor their condition are often complex. The proposed damage identification method is based on the minimum mean squared error estimator and the generalized likelihood ratio test. It introduced activation function to generate the standard deviation of the data, which can then simulate the sensor output. A single sensor damage only affects a single dimension of the output data matrix of the measurement system. However, structural damage affects the output of multiple sensors. The damage identification method proposed in this paper can not only distinguish the sensor damage from the structure damage, but also locate the damaged sensor or structure damage location. This method can identify the measurement system output anomalies caused by structural damage and locate the approximate location of the damage. It can be applied to damage identification of important structural members such as flexible wind tunnel plates. The damage identification method proposed in this paper is of great significance for damage identification and localization of key components and sensor systems.


  • Open Access

    Residual Strain Monitoring and Dynamic Characteristics of Hybrid Hollow Square Tube with Metal–FRP–Metal Sandwich Walls

    by Zhao Li, Mingyao Liu, Jintao Wang, Wei Ke

    In order to design and fabricate a novel hollow square tube (HST) for ram structure in machine tools, the hybrid HST with sandwich walls based on steel skins and unidirectional carbon fiber-reinforced polymer (CFRP) composite core is proposed. A detailed co-cured fabrication method with embedded fiber Bragg grating (FBG) sensors for residual strains/stresses determination in a hybrid metal–composite structure is presented. Results reveal that the hybrid HST has undergone complex residual strain history, and the strain rate is about 10 times the cooling rate. The tensile strains in the dwell stage transform into compressive strains in the cooling stage due to the mismatch of the coefficients of thermal expansion of the steel plates and the CFRP composite. A comparison of the residual strains in the cooling phase obtained by FBG sensors with those obtained by theoretical calculation is carried out. Furthermore, the dynamic characteristics of the hybrid HST and the steel HST are tested. The results showed that the damping of the hybrid HST is 586% higher than that of the steel HST, while the hybrid HST has a lower first natural frequency (4.6% reduction) and mass (15.9% weight reduction). The influence of co-cure temperature and cooling rate on the size and state of the residual strains is analyzed, which might be helpful to guide the manufacturing of sandwich structures in machine tools. This novel hybrid HST may be used for online health monitoring and safety evaluation to build intelligent machine tools structures.


  • Open Access

    Reduction of Thermal Residual Strain in a Metal-CFRP-Metal Hybrid Tube Using an Axial Preload Tool Monitored through Optical Fiber Sensors

    by Zhao Li, Wei Ke, Mingyao Liu, Yang Zhou

    Thermal residual strains/stresses cause several defects in hybrid structures and various studies have reported the reduction of residual strain. This paper describes a method for reducing thermal residual strains/stresses in metal-CFRP-metal hybrid tubes (MCMHT). The proposed axial preload tool provides two ways to reduce the thermal residual strains/stresses during the co-cure bonding process: pre-compressing of the metal layers and pre-stretching of the unidirectional carbon fiber reinforced polymer (CFRP) layers. An online measurement technique with embedded optical fiber Bragg grating (FBG) sensors is presented. Thermal residual strains are evaluated based on classical lamination theory with the assumption of plane stress. The theoretical calculations and measurement results agree well. Furthermore, the dynamic characteristics of the MCMHTs are tested. The results show that the reduction of residual strain increases the natural frequency of the MCMHT, but is detrimental to the damping capability of the MCMHT, which imply that the intrinsic properties of the metal-composite hybrid structure can be modified by the proposed axial preload tool.


  • Design and Optimization of an FBG Accelerometer Based on Single-Notch Circular Flexure Hinge for Medium-Frequency Vibration Measurement

    by Li Zhang, Mingyao Liu, Liu Hong, Cong Li, Zude Zhou

    This paper proposes a novel hinge-type fiber Bragg grating (FBG) accelerometer for measuring medium-frequency vertical vibrations that employs a single-notch circular flexure hinge as the elastomer of the accelerometer. The proposed elastomer allows for the simultaneous realization of high sensitivity, a compact structure and a relatively wide working frequency range, all of which are critical for accelerometer performance. The working principle and detailed theoretical analysis of the FBG accelerometer are illustrated and conducted. Moreover, the sensitivity of the accelerometer is optimized further through a genetic algorithm in order to strike a balance between miniaturization and resonance frequency. Finite element analysis and experimental tests were carried out to validate the performance of the accelerometer. The results indicate that the proposed FBG accelerometer has a resonant frequency of 800 Hz and a working frequency range of 50 – 450 Hz, with the sensitivity of approximately 65 pm/g at an exciting frequency of 100Hz between the fiber central wavelength and vibration acceleration. The results also demonstrate that the proposed accelerometer exhibits a good linear relationship with the frequency of vibration accelerations, as well as good anti-interference properties with the horizontal vibrations. It has the potential to provide a novel and simple solution for monitoring medium-frequency vibration signals in complex environments characterized by high levels of electromagnetic interference, such as in aeronautical hydraulic systems.


  • A Temperature and Magnetic Field-Based Approach for Stator Inter-Turn Fault Detection

    by Yi-Hang Wu, Ming-Yao Liu, Han Song, Cong Li, Xue-Li Yang

    Effective fault detection techniques are needed to reduce the maintenance and downtime costs of induction motors. This article presents an approach for stator end-winding inter-turn short-circuit fault detection using a metal-coated fiber Bragg grating (FBG) sensor with 0.5-mm diameter and 10-mm length to monitor the temperature and magnetic field around the end winding. The sensing theory, design, manufacturing, and installation of the sensor are detailed in this article. The nickel coating on the surface of the sensor is formed by electroless plating and electroplating, which makes the sensor sensitive to both temperature and magnetic field. The feasibility of the presented approach has been supported by both simulation and experimental results. The temperature and magnetic field signals are decoupled by filtering, and the experimental data are analyzed in the time-frequency domain. The results show that the inter-turn short-circuit fault can be detected at an incipient stage with 5% shorted turns.


  • A Non-Invasive Measurement Method of Pipeline Flow Rate Based on Dual FBG Sensors

    by Cong Li, Ming-Yao Liu, Han Song, Xue-Li Yang, Yi-Hang Wu

    Combining fiber Bragg grating (FBG) sensors and finite element simulation analysis, an online monitoring method for non-invasive distributed flow velocity in pipelines has been proposed. A placement strategy has been proposed for the deployment of these FBG sensors to ensure effective sensing of strain. The cross-sensitivity problem of FBG sensors can be solved by differential FBG measurements. The principle of online monitoring of flow velocity based on the flow velocity function and finite element analysis is described and derived. Finite element analysis results show the $\boldsymbol {\varepsilon }_{1}- \boldsymbol {\varepsilon }_{2}$ at 45° of the elbow of the bend is quadratically proportional to the flow velocity. Meanwhile, the feasibility of the method is verified by experiments. The calibration results show a fitted correlation coefficient R 2 = 0.9982 in the velocity range of 4.25-10.62m/s, fitted by least squares to the wavelength data. The repeatability error of the flow measurement of the proposed sensor is no more than 5.06%FS. Compared with the existing literature, the method proposed in this paper has a wider range of flow velocity measurement and applications, especially suitable for applications with strong electromagnetic interference capability and harsher environment, showing great potential for engineering applications, especially in the distributed detection of long-distance pipeline networks.


  • Top Cited Papers

    A Model-Driven Scheme to Compensate the Strain-Based Non-Intrusive Dynamic Pressure Measurement for Hydraulic Pipe

    by Zechao Wang, Mingyao Liu, Wang-Ji Yan, Han Song, Zude Zhou, Ka-Veng Yuen, Qin Wei, Shing Shin Cheng

    Strain-based non-intrusive approaches for measuring the pressure of pipes have attracted widespread attention due to their great convenience and ability to avoid destroying the integrity of structures. However, the mentioned method usually measures the dynamic pressure based only on the static strain–pressure sensitivity coefficients (SSSCs) instead of the dynamic strain–pressure sensitivity coefficients (DSSCs) due to its complicated calibration, which will inevitably affect the accuracy significantly. To address this issue, a model-driven scheme with dual stages is proposed in the present study to compensate the dynamic pressure measurement. The DSSCs are analytically derived for the first time from the axial governing equations of the pipe, considering the general boundary conditions for the thin-walled and thick-walled pipes simultaneously. In the first stage, the physical parameters involved in the DSSCs are calibrated by minimizing the residual of the experimental results and the theoretical counterparts. In the second stage, the DSSCs calculated from the calibrated analytical model are utilized to compensate the dynamic pressure based on the relationship between the DSSCs and the SSSCs. The proposed method is applied to an industrial hydraulic pipe system, and the experimental results show that the relative error is reduced greatly after the compensation is implemented, demonstrating the validity of the proposed compensation method.


  • Miniature Structure Optimization of Small-Diameter FBG-Based One-Dimensional Optical Fiber Vibration Sensor

    by Han Song, Enzhong Song, Wang Peng, Boyi Wang, Yi Liu, Guangyao Zhao, Mingyao Liu

    We proposed a miniature one-dimensional vibration sensor based on a small-diameter fiber Bragg grating in this paper. The working principle and theoretical model of the FBG vibration sensor were deduced and established theoretically. A genetic algorithm has been used to globally optimize the nonlinear programming problem of sensor size and sensitivity. The modal analysis of the vibration sensor was carried out by using finite element software to verify the feasibility of the optimization results. Then metal 3D printing was utilized to realize the integrated processing and miniaturization of the sensor. The experimental results show that the natural frequency of the sensor packaged with the small-diameter FBG is 1949.5Hz, and the sensor has a good working state in the frequency range of 5-1300Hz. The sensitivity and the linearity of the optimized sensor are 65.42 pm/g and 99.997% at the frequency of 100Hz, respectively. Through the comparative experiments, it can be found that the small-diameter FBG presents an obvious sensitization effect compared to the ordinary FBG with a 118.3% sensitivity improvement. This optimization theory is promising in multi-dimension, high performance, and microminiaturization optical vibration sensor design and fabrication.