Lorena Gordillo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lorena Gordillo has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Bruno Marco
GMME-CEMDATIC, ETSI de Telecomunicación, Universidad Politécnica de Madrid, 28040 Madrid, Spain
1 shared publication - Diego Megías
Instituto de Salud Carlos III
1 shared publication - Enrique Iborra
GMME-CEMDATIC, ETSI de Telecomunicación, Universidad Politécnica de Madrid, Spain
1 shared publication - Jimena Olivares
GMME-CEMDATIC, ETSI de Telecomunicación, Universidad Politécnica de Madrid, 28040 Madrid, Spain
1 shared publication - José Miguel Escolano
GMME-CEMDATIC, ETSI de Telecomunicación, Universidad Politécnica de Madrid, 28040 Madrid, Spain
1 shared publication - Marta Clement
GMME-CEMDATIC, ETSI de Telecomunicación, Universidad Politécnica de Madrid, 28040 Madrid, Spain
1 shared publication
Latest Publications
- Open Access
- 7 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 539
Integration of Graphene on AlN Based High Frequency Resonators and Their Functionalization for Biosensing
We present the successful integration of graphene on top of AlN-based solidly mounted resonators (SMRs), using a low temperature CVD process and Ni layers as catalyst. We develop a protocol to functionalize the surface of the resonators that starts with a low damage O2 radical plasma treatment of the surface of the devices that introduces a controlled density of defects on the graphene. Then, EDC/NHS chemistry is used to covalently bond streptavidin molecules to the surface of the sensors. Finally, the functionalised biosensors are assessed by analysing their response to biotinylated antibodies.
- 7 August 2017
- Published by MDPI AG in Proceedings
- Vol. 1 (4) , 539
Open AccessIntegration of Graphene on AlN Based High Frequency Resonators and Their Functionalization for Biosensing
We present the successful integration of graphene on top of AlN-based solidly mounted resonators (SMRs), using a low temperature CVD process and Ni layers as catalyst. We develop a protocol to functionalize the surface of the resonators that starts with a low damage O2 radical plasma treatment of the surface of the devices that introduces a controlled density of defects on the graphene. Then, EDC/NHS chemistry is used to covalently bond streptavidin molecules to the surface of the sensors. Finally, the functionalised biosensors are assessed by analysing their response to biotinylated antibodies.