HLHuiyun Li
Huiyun Li
*This is an algorithmically generated author record based on publicly available information.
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Huiyun Li has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Aibin Ma
College of Materials Science and Engineering, Hohai University, Nanjing 210098, China
1 shared publication - Jinghua Jiang
College of Materials Science and Engineering, Hohai University, Jintan, China
1 shared publication - Yanxia Gu
College of Marine and Electrical Engineering, Jiangsu Maritime Institute, Nanjing 211100, China
1 shared publication - Yuchun Yuan
College of Mechanics and Materials, Hohai University, Nanjing 211100, China
1 shared publication
Latest Publications
- Open Access
Deformation Structure and Mechanical Properties of Pure Titanium Produced by Rotary-Die Equal-Channel Angular Pressing
Pure titanium was efficiently processed up to four passes at 420 °C by rotary-die equal-channel angular pressing (RD-ECAP). The deformation structure and mechanical properties of pure titanium with various RD-ECAP passes were subsequently investigated. Microstructure evolution revealed that plastic deformation was accommodated mainly by twins during the first and second passes, while the predominant deformation mechanism was dislocation slip during the third and fourth passes. { } twins were detected in the first pass, and { } twins occurred in the second pass of RD-ECAP. The ultimate tensile strength of pure titanium increased from 450 MPa in the as-received state to 627 MPa with a fracture elongation of 29% after four passes of RD-ECAP.Open AccessDeformation Structure and Mechanical Properties of Pure Titanium Produced by Rotary-Die Equal-Channel Angular Pressing
Pure titanium was efficiently processed up to four passes at 420 °C by rotary-die equal-channel angular pressing (RD-ECAP). The deformation structure and mechanical properties of pure titanium with various RD-ECAP passes were subsequently investigated. Microstructure evolution revealed that plastic deformation was accommodated mainly by twins during the first and second passes, while the predominant deformation mechanism was dislocation slip during the third and fourth passes. { } twins were detected in the first pass, and { } twins occurred in the second pass of RD-ECAP. The ultimate tensile strength of pure titanium increased from 450 MPa in the as-received state to 627 MPa with a fracture elongation of 29% after four passes of RD-ECAP.