Yonghua You
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yonghua You has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Aiwu Fan
Huazhong University of Science and Technology
1 shared publication - Dong Zhang
School of Material and Metallurgy, Wuhan University of Science and Technology, Wuhan 430081, China
1 shared publication - Jie Yu
School of Material and Metallurgy, Wuhan University of Science and Technology, Wuhan 430081, China
1 shared publication - Kun Shao
State Key Lab. of Refractories and Metallurgy, Wuhan University of Science and Technology, Wuhan 430081, China
1 shared publication Miaoxin Han
State Key Lab. of Refractories and Metallurgy, Wuhan University of Science and Technology (WUST), Wuhan, People’s Republic of China
1 shared publicationNi Pan
State Key Laboratory of Refractories and Metallurgy, Wuhan University of Science and Technology, Wuhan, China
1 shared publication
Latest Publications
- Open Access
- 21 July 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (14) , 7276
A Numerical Study on Falling Film Evaporation with Wall Heat Flux and Pulsating Airflow
In the current work, pulsating airflow and an external heat source are proposed to improve the evaporation performance of falling films. A volume of fluid (VOF) multiphase flow model is established based on the commercial software ANSYS Fluent 2023 R1 (ANSYS, Inc., Canonsburg, PA, USA) to simulate the falling film evaporation process. Numerical simulations are conducted under combined working conditions with variable average inlet velocity (u0), relative pulsating amplitude (A), and wall heat flux (qw). The spatial and temporal distributions of physical fields are visualized via numerical contours and characteristic curves, and the heat and mass transfer enhancement mechanism is revealed from three aspects, namely, the promotion of driving potential difference by wall heat flux, the increase in heat and mass transfer gradients induced by pulsating airflow, and the synergistic effect of the above two factors. The results indicate that the evaporation ratio (Ψ) increases monotonically with the rise of u0, with a maximum growth rate of 83.8%. By contrast, under the condition of fixed A0 = 1 m/s while varying u0, the evaporation ratio exhibits a convex variation with the relative amplitude A = A0/u0, and the global optimal value is achieved at A = 1/6, corresponding to u0 = 6 m/s and A0 = 1 m/s. Comparative analysis demonstrates that wall heat flux exerts a more significant influence on evaporation performance than pulsating airflow. Specifically, the evaporation ratio at qw = 10,000 W/m2 is 3~4 times higher than that under the adiabatic wall condition. The reliability of the numerical model is first confirmed by comparing the predictions with published experimental data for vertical falling film evaporation. Based on this validated model, the quantified parametric effects and optimal operating conditions provide practical design references for falling film evaporators in seawater desalination and related thermal separation applications.
- 21 July 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (14) , 7276
Open AccessA Numerical Study on Falling Film Evaporation with Wall Heat Flux and Pulsating Airflow
In the current work, pulsating airflow and an external heat source are proposed to improve the evaporation performance of falling films. A volume of fluid (VOF) multiphase flow model is established based on the commercial software ANSYS Fluent 2023 R1 (ANSYS, Inc., Canonsburg, PA, USA) to simulate the falling film evaporation process. Numerical simulations are conducted under combined working conditions with variable average inlet velocity (u0), relative pulsating amplitude (A), and wall heat flux (qw). The spatial and temporal distributions of physical fields are visualized via numerical contours and characteristic curves, and the heat and mass transfer enhancement mechanism is revealed from three aspects, namely, the promotion of driving potential difference by wall heat flux, the increase in heat and mass transfer gradients induced by pulsating airflow, and the synergistic effect of the above two factors. The results indicate that the evaporation ratio (Ψ) increases monotonically with the rise of u0, with a maximum growth rate of 83.8%. By contrast, under the condition of fixed A0 = 1 m/s while varying u0, the evaporation ratio exhibits a convex variation with the relative amplitude A = A0/u0, and the global optimal value is achieved at A = 1/6, corresponding to u0 = 6 m/s and A0 = 1 m/s. Comparative analysis demonstrates that wall heat flux exerts a more significant influence on evaporation performance than pulsating airflow. Specifically, the evaporation ratio at qw = 10,000 W/m2 is 3~4 times higher than that under the adiabatic wall condition. The reliability of the numerical model is first confirmed by comparing the predictions with published experimental data for vertical falling film evaporation. Based on this validated model, the quantified parametric effects and optimal operating conditions provide practical design references for falling film evaporators in seawater desalination and related thermal separation applications.
- 3 March 2024
- Published by Taylor & Francis in Journal of Turbulence
- Vol. 25 (1-3) , 83-104
Multi-spatial scale and multi-frequency resolution Proper Orthogonal Decomposition for patterns of wall-streamwise pressure gradient fluctuation of impinging jets
- 3 March 2024
- Published by Taylor & Francis in Journal of Turbulence
- Vol. 25 (1-3) , 83-104
Multi-spatial scale and multi-frequency resolution Proper Orthogonal Decomposition for patterns of wall-streamwise pressure gradient fluctuation of impinging jets
- Open Access
Dynamic Heat Dissipation Model of Distributed Parameters for Oil-Directed and Air-Forced Traction Transformers and Its Experimental Validation
A traction transformer with narrow oil channels is usually cooled with the ODAF or “Oil Directed Air Forced” method, where its temperature greatly depends on the Joule heat of windings, the conjugate heat transfer in the transformer, and the secondary heat release via oil cooler, together with the oil flowrate generated by oil pump. Neither the thermal–electric analogy nor the CFD simulation approach is qualified to predict the temporal and spatial temperature variations in this type of transformer. In the current work, the distributed parameter models are built for traction transformers and oil coolers with the assumption of a one-dimensional temperature field in the oil flow direction, respectively. Then, the two models are combined with the lumped parameter ones of oil pumps and pipes via the flow rate, temperature and pressure continuities at their interfaces, resulting in the derivation of the dynamic heat dissipation model of oil-directed and air-forced traction transformers. Additionally, an efficient algorithm is proposed for its numerical solution, and the temperature rise experiment is performed for model validation. Finally, the fundamental of dynamic heat dissipation in traction transformers is investigated with the current numerical model and the effects of ambient temperature are studied.
Open AccessDynamic Heat Dissipation Model of Distributed Parameters for Oil-Directed and Air-Forced Traction Transformers and Its Experimental Validation
A traction transformer with narrow oil channels is usually cooled with the ODAF or “Oil Directed Air Forced” method, where its temperature greatly depends on the Joule heat of windings, the conjugate heat transfer in the transformer, and the secondary heat release via oil cooler, together with the oil flowrate generated by oil pump. Neither the thermal–electric analogy nor the CFD simulation approach is qualified to predict the temporal and spatial temperature variations in this type of transformer. In the current work, the distributed parameter models are built for traction transformers and oil coolers with the assumption of a one-dimensional temperature field in the oil flow direction, respectively. Then, the two models are combined with the lumped parameter ones of oil pumps and pipes via the flow rate, temperature and pressure continuities at their interfaces, resulting in the derivation of the dynamic heat dissipation model of oil-directed and air-forced traction transformers. Additionally, an efficient algorithm is proposed for its numerical solution, and the temperature rise experiment is performed for model validation. Finally, the fundamental of dynamic heat dissipation in traction transformers is investigated with the current numerical model and the effects of ambient temperature are studied.
- Open Access
Refrigeration Performance and Entropy Generation Analysis for Reciprocating Magnetic Refrigerator with Gd Plates
In the current work, a novel 2D numerical model of stationary grids was developed for reciprocating magnetic refrigerators, with Gd plates, in which the magneto-caloric properties, derived from the Weiss molecular field theory, were adopted for the built-in energy source of the magneto-caloric effect. The numerical simulation was conducted under the conditions of different structural and operational parameters, and the effects of the relative fluid displacement (φ) on the specific refrigeration capacity (qref) and the Coefficient of Performance (COP) were obtained. Besides the variations of entropy, the generation rate and number were studied and the contours of the local entropy generation rate are presented for discussion. From the current work, it is found that with an increase in φ, both the qref and COP followed the convex variation trend, while the entropy generation number (Ns) varied concavely. As for the current cases, the maximal qref and COP were equal to 151.2 kW/m3 and 9.11, respectively, while the lowest Ns was the value of 2.4 × 10−4 K−1. However, the optimal φ for the largest qref and COP, and for the lowest Ns, were inconsistent, thus, some compromises need be made in the optimization of magnetic refrigerators.
Open AccessRefrigeration Performance and Entropy Generation Analysis for Reciprocating Magnetic Refrigerator with Gd Plates
In the current work, a novel 2D numerical model of stationary grids was developed for reciprocating magnetic refrigerators, with Gd plates, in which the magneto-caloric properties, derived from the Weiss molecular field theory, were adopted for the built-in energy source of the magneto-caloric effect. The numerical simulation was conducted under the conditions of different structural and operational parameters, and the effects of the relative fluid displacement (φ) on the specific refrigeration capacity (qref) and the Coefficient of Performance (COP) were obtained. Besides the variations of entropy, the generation rate and number were studied and the contours of the local entropy generation rate are presented for discussion. From the current work, it is found that with an increase in φ, both the qref and COP followed the convex variation trend, while the entropy generation number (Ns) varied concavely. As for the current cases, the maximal qref and COP were equal to 151.2 kW/m3 and 9.11, respectively, while the lowest Ns was the value of 2.4 × 10−4 K−1. However, the optimal φ for the largest qref and COP, and for the lowest Ns, were inconsistent, thus, some compromises need be made in the optimization of magnetic refrigerators.
- 1 January 2018
- Published by Taylor & Francis in Heat Transfer Engineering
- Vol. 39 (12) , 1024-1035
Full Model Simulation of Shellside Thermal Augmentation of Small Heat Exchanger with Two Tube Passes
- 1 January 2018
- Published by Taylor & Francis in Heat Transfer Engineering
- Vol. 39 (12) , 1024-1035
Full Model Simulation of Shellside Thermal Augmentation of Small Heat Exchanger with Two Tube Passes