Hao Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hao Hu has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Yanrui Zhang
School of Energy and Power, Jiangsu University of Science and Technology, Zhenjiang 212000, China
1 shared publication - Yimeng Zhou
School of Energy and Power, Jiangsu University of Science and Technology, Zhenjiang 212000, China
1 shared publication - Yong Zhang
School of Energy and Power, Jiangsu University of Science and Technology, Zhenjiang 212000, China
1 shared publication - Zhongchao Zhao
School of Energy and Power Engineering, Jiangsu University of Science and Technology, Zhenjiang 212100, China
1 shared publication
Latest Publications
- Open Access
Numerical Study on the Transient Thermal Performance of a Two-Phase Closed Thermosyphon
The transient thermal performance of phase change and heat and mass transfer in a two-phase closed thermosyphon are studied with computational fluid dynamics (CFD). A CFD model based on the volume of fluid technique is built. Deionized water is specified as the working fluid of this thermosyphon. The CFD model reproduces evaporation and condensation in the thermosyphon at different heating inputs. The average wall temperatures are also analyzed. Variations of average wall temperatures indicate that this thermosyphon reaches a steady state after 19 s, and starts to work in advance when the heating input increases. Moreover, thermal resistance is decreased until a minimum (0.552 K/W) by increasing the heating input, and the effective thermal conductivity is elevated to a maximum (2.07 × 106 W/m∙K).
Open AccessNumerical Study on the Transient Thermal Performance of a Two-Phase Closed Thermosyphon
The transient thermal performance of phase change and heat and mass transfer in a two-phase closed thermosyphon are studied with computational fluid dynamics (CFD). A CFD model based on the volume of fluid technique is built. Deionized water is specified as the working fluid of this thermosyphon. The CFD model reproduces evaporation and condensation in the thermosyphon at different heating inputs. The average wall temperatures are also analyzed. Variations of average wall temperatures indicate that this thermosyphon reaches a steady state after 19 s, and starts to work in advance when the heating input increases. Moreover, thermal resistance is decreased until a minimum (0.552 K/W) by increasing the heating input, and the effective thermal conductivity is elevated to a maximum (2.07 × 106 W/m∙K).