YTYuan Tao

Yuan Tao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yuan Tao has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Fast Calculation Method for Transient Response of Transmission Line Based on Chebyshev Pseudospectral–Two-Step Three-Order Boundary Value Coupled Method

    by Zhenhua Li, Tinghe Hu, Yuan Tao, Tao Zhang, Zhenxing Li

    A Chebyshev pseudospectral–two-step three-order boundary value coupled method is proposed and presented for handling the issue associated with complicated calculation, low precision, and poor stability in the process of transient response of transmission line. The first order differential equation in time domain is obtained via dispersing the telegraph equation in space domain by utilizing the pseudospectral method (PSM) based on Chebyshev polynomial. Then the two-step three-order boundary value method (BVM3) is presented and employed to resolve the obtained differential equation, so the numerical solution of the space discrete points can be obtained. Furthermore, the Chebyshev pseudospectral–two-step three-order boundary value coupled method (PSM-BVM3) is presented and compared with the Chebyshev pseudospectral–two-step two order boundary value coupled method (PSM-BVM2), the pseudospectral–differential quadrature method (PSM-DQM), and the pseudospectral method–trapezoid rule (PSM-TR) to validate the feasibility of the new proposed method. Theoretical analysis and numerical simulation reveal that the proposed Chebyshev PSM-BVM3 has a higher performance than the conventional method. For the proposed Chebyshev PSM-BVM3, the higher precision, efficiency, and numerical stability can be obtained and achieved only with fewer discrete points in the space domain, which is suitable for solving the transient response of transmission line. The proposed PSM-BVM3 can improve the drawback of numerical instability of the PSM and can also improve the disadvantage of the BVM as it is not easy to change the latter’s timestep size.


  • Open Access

    Study of Current Measurement Method Based on Circular Magnetic Field Sensing Array

    by Zhenhua Li, Siqiu Zhang, Zhengtian Wu, Ahmed Abu-Siada, Yuan Tao

    Classic core-based instrument transformers are more prone to magnetic saturation. This affects the measurement accuracy of such transformers and limits their applications in measuring large direct current (DC). Moreover, protection and control systems may exhibit malfunctions due to such measurement errors. This paper presents a more accurate method for current measurement based on a circular magnetic field sensing array. The proposed measurement approach utilizes multiple hall sensors that are evenly distributed on a circle. The average value of all hall sensors is regarded as the final measurement. The calculation model is established in the case of magnetic field interference of the parallel wire, and the simulation results show that the error decreases significantly when the number of hall sensors n is greater than 8. The measurement error is less than 0.06% when the wire spacing is greater than 2.5 times the radius of the sensor array. A simulation study on the off-center primary conductor is conducted, and a kind of hall sensor compensation method is adopted to improve the accuracy. The simulation and test results indicate that the measurement error of the system is less than 0.1%.