Peter Zaťko
Peter Zaťko has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Niemczanowski
Versuchsanstalt TGM, Fachbereich Akustik und Bauphysik, Wexstrasse 19-23, 1200 Wien, Austria
1 shared publication - Christ Glorieux
Department of Physics and Astronomy, KU Leuven, Soft Matter and Biophysics Unit, Leuven, Belgium
1 shared publication - Daniel Urbán
Research Division for Building Physics, Institute of Material Technology, Building Physics, and Building Ecology, Faculty of Civil Engineering, Technische Universität Wien
1 shared publication - Herbert Muellner
Versuchsanstalt TGM, Fachbereich Akustik und Bauphysik, Wexstrasse 19-23, 1200 Wien, Austria
1 shared publication - Monika Rychtáriková
Department of Architecture, KU Leuven, Leuven, Belgium
1 shared publication - Nicolaas Bernardus Roozen
Philips Research Laboratories, Prof. Holstlaan 4, 5656 AA Eindhoven, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 2 May 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (5) , 703
Vibrometry Assessment of the External Thermal Composite Insulation Systems Influence on the Façade Airborne Sound Insulation
This paper verifies the impact of the use of an external thermal composite system (ETICS) on air-borne sound insulation. For optimum accuracy over a wide frequency range, classical microphone based transmission measurements are combined with accelerometer based vibrometry measurements. Consistency is found between structural resonance frequencies and bending wave velocity dispersion curves determined by vibrometry on the one hand and spectral features of the sound reduction index, the ETICS mass-spring-mass resonance induced dip in the acoustic insulation spectrum, and the coincidence induced dip on the other hand. Scanning vibrometry proves to be an effective tool for structural assessment in the design phase of ETICS systems. The measured spectra are obtained with high resolution in wide frequency range, and yield sound insulation values are not affected by the room acoustic features of the laboratory transmission rooms. The complementarity between the microphone and accelerometer based results allows assessing the effect of ETICS on the sound insulation spectrum in an extended frequency range from 20 Hz to 10 kHz. The modified engineering ΔR prediction model for frequency range up to coincidence frequency of external plaster layer is recommended. Values for the sound reduction index obtained by a modified prediction method are consistent with the measured data.
- 2 May 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (5) , 703
Open AccessVibrometry Assessment of the External Thermal Composite Insulation Systems Influence on the Façade Airborne Sound Insulation
This paper verifies the impact of the use of an external thermal composite system (ETICS) on air-borne sound insulation. For optimum accuracy over a wide frequency range, classical microphone based transmission measurements are combined with accelerometer based vibrometry measurements. Consistency is found between structural resonance frequencies and bending wave velocity dispersion curves determined by vibrometry on the one hand and spectral features of the sound reduction index, the ETICS mass-spring-mass resonance induced dip in the acoustic insulation spectrum, and the coincidence induced dip on the other hand. Scanning vibrometry proves to be an effective tool for structural assessment in the design phase of ETICS systems. The measured spectra are obtained with high resolution in wide frequency range, and yield sound insulation values are not affected by the room acoustic features of the laboratory transmission rooms. The complementarity between the microphone and accelerometer based results allows assessing the effect of ETICS on the sound insulation spectrum in an extended frequency range from 20 Hz to 10 kHz. The modified engineering ΔR prediction model for frequency range up to coincidence frequency of external plaster layer is recommended. Values for the sound reduction index obtained by a modified prediction method are consistent with the measured data.