Siwei Han
Siwei Han has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Jiong Shen
Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, School of Energy and Environment, Southeast University, Nanjing 210096, China
2 shared publications - Lei Pan
School of Energy and Environment, Southeast University, Nanjing 211189, China
2 shared publications - Li Sun
National Engineering Research Center of Power Generation Control and Safety, School of Energy and Environment, Southeast University, Nanjing 210096, China
2 shared publications - Chengyu Cao
University of Connecticut
1 shared publication - De-Wen Zhang
Xi’an Jiaotong University
1 shared publication - Kexin Zhang
Institute of Cyber-Systems and Control, Zhejiang University, Hangzhou 310027, China
1 shared publication
Latest Publications
- Open Access
- 1 May 2020
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 514 (4) , 042062
Research on Key Technologies of Power System Automation Application under Smart Grid
With the continuous development of the scale of the power grid and the advancement of the integrated mode of regulation and control, the amount of real-time monitoring information in the power grid system has grown rapidly today, which has imposed a great burden on all levels of dispatch monitoring. The old alarm function of the power dispatching automation system has been unable to better meet the needs of efficient monitoring. Therefore, it is necessary to brush, analyse, process and summarize the alarm information of each link in the monitoring business, so as to improve the overall operation status of the power grid. Awareness and processing speed of abnormal faults. Based on this, this paper discusses and studies the smart alarms of the smart grid, analyses the overall architecture, and analyses several smart alarm technologies used in the smart grid system on this basis, with a view to the subsequent development of smart grids and alarms the technical research provides a theoretical reference.
- 1 May 2020
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 514 (4) , 042062
Open AccessResearch on Key Technologies of Power System Automation Application under Smart Grid
With the continuous development of the scale of the power grid and the advancement of the integrated mode of regulation and control, the amount of real-time monitoring information in the power grid system has grown rapidly today, which has imposed a great burden on all levels of dispatch monitoring. The old alarm function of the power dispatching automation system has been unable to better meet the needs of efficient monitoring. Therefore, it is necessary to brush, analyse, process and summarize the alarm information of each link in the monitoring business, so as to improve the overall operation status of the power grid. Awareness and processing speed of abnormal faults. Based on this, this paper discusses and studies the smart alarms of the smart grid, analyses the overall architecture, and analyses several smart alarm technologies used in the smart grid system on this basis, with a view to the subsequent development of smart grids and alarms the technical research provides a theoretical reference.
- 1 January 2020
- Published by Elsevier in ISA Transactions
- Vol. 96, 415-428
A L1-LEMPC hierarchical control structure for economic load-tracking of super-critical power plants
- 1 January 2020
- Published by Elsevier in ISA Transactions
- Vol. 96, 415-428
A L1-LEMPC hierarchical control structure for economic load-tracking of super-critical power plants
- Open Access
Optimal Load-Tracking Operation of Grid-Connected Solid Oxide Fuel Cells through Set Point Scheduling and Combined L1-MPC Control
An optimal load-tracking operation strategy for a grid-connected tubular solid oxide fuel cell (SOFC) is studied based on the steady-state analysis of the system thermodynamics and electrochemistry. Control of the SOFC is achieved by a two-level hierarchical control system. In the upper level, optimal setpoints of output voltage and the current corresponding to unit load demand is obtained through a nonlinear optimization by minimizing the SOFC’s internal power waste. In the lower level, a combined L1-MPC control strategy is designed to achieve fast set point tracking under system nonlinearities, while maintaining a constant fuel utilization factor. To prevent fuel starvation during the transient state resulting from the output power surging, a fuel flow constraint is imposed on the MPC with direct electron balance calculation. The proposed control schemes are testified on the grid-connected SOFC model.
Open AccessOptimal Load-Tracking Operation of Grid-Connected Solid Oxide Fuel Cells through Set Point Scheduling and Combined L1-MPC Control
An optimal load-tracking operation strategy for a grid-connected tubular solid oxide fuel cell (SOFC) is studied based on the steady-state analysis of the system thermodynamics and electrochemistry. Control of the SOFC is achieved by a two-level hierarchical control system. In the upper level, optimal setpoints of output voltage and the current corresponding to unit load demand is obtained through a nonlinear optimization by minimizing the SOFC’s internal power waste. In the lower level, a combined L1-MPC control strategy is designed to achieve fast set point tracking under system nonlinearities, while maintaining a constant fuel utilization factor. To prevent fuel starvation during the transient state resulting from the output power surging, a fuel flow constraint is imposed on the MPC with direct electron balance calculation. The proposed control schemes are testified on the grid-connected SOFC model.