Pei Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Pei Zhang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Likai Liang
School of Mechanical, Electrical and Information Engineering, Shandong University (Weihai), Weihai 264209, China
1 shared publication - Mingqiang Wang
Key Laboratory of Power System Intelligent Dispatch and Control, Ministry of Education, Shandong University, Jinan, China
1 shared publication - Xiaofeng Zhou
Department of Mechanical-Electrical Engineering, Weihai Vocational College, Weihai 264210, China
1 shared publication - Yang Mo
Shandong Univ, Weihai, Peoples R China
1 shared publication - Yanling Wang
School of Mechanical, Electrical and Information Engineering Shandong University Weihai China
1 shared publication
Latest Publications
- Open Access
Impact of Conductor Temperature Time–Space Variation on the Power System Operational State
The conductor temperature of an overhead transmission line varies with time and space, which has an important impact on the system operation. In this paper, the conductor temperature is solved iteratively by the CIGRE heat balance equation. The time–space variation of conductor temperature of a 220-kV transmission line is analyzed using real meteorological data from Weihai. Considering the temporal distribution characteristics, the seasonal model of the conductor temperature is given. Considering the spatial distribution, the mean value model, the weight average model, and the segmentation model are established. The system power flow involving the conductor temperature is established based on the relationship between conductor temperature and transmission line parameters. Through the calculation of power flow and the analysis of the maximum power transmission capability, the accuracy of the segmentation model is verified. The results show that the conductor temperature of overhead lines has obvious time–space variation characteristics. It is necessary to consider the time–space variation when analyzing the operation state of power systems.
Open AccessImpact of Conductor Temperature Time–Space Variation on the Power System Operational State
The conductor temperature of an overhead transmission line varies with time and space, which has an important impact on the system operation. In this paper, the conductor temperature is solved iteratively by the CIGRE heat balance equation. The time–space variation of conductor temperature of a 220-kV transmission line is analyzed using real meteorological data from Weihai. Considering the temporal distribution characteristics, the seasonal model of the conductor temperature is given. Considering the spatial distribution, the mean value model, the weight average model, and the segmentation model are established. The system power flow involving the conductor temperature is established based on the relationship between conductor temperature and transmission line parameters. Through the calculation of power flow and the analysis of the maximum power transmission capability, the accuracy of the segmentation model is verified. The results show that the conductor temperature of overhead lines has obvious time–space variation characteristics. It is necessary to consider the time–space variation when analyzing the operation state of power systems.