JYJinsong Yu

Jinsong Yu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jinsong Yu has a total of 3 co-authors. Here are the top co-authors by number of shared publications:

  • A. G. Agwu Nnanna

    Purdue Water Institute, Purdue University Calumet, Hammond, Indiana 46323, USA

    1 shared publication
  • Ahmed Hasnain Jalal

    Purdue Water Institute, Purdue University Calumet, Hammond, Indiana 46323, USA

    1 shared publication
  • Chung Chiun Liu

    Department of Chemical and Biomolecular Engineering, Case Western Reserve University, Cleveland, OH 44106, USA

    1 shared publication

Latest Publications

  • Fabrication and calibration of Oxazine-based optic fiber sensor for detection of ammonia in water

    by Ahmed Hasnain Jalal, Jinsong Yu, A. G. Agwu Nnanna

    This paper presented the fabrication and calibration of a clad-modified evanescent based plastic optical fiber (POF) sensor for the detection of ammonia in both stagnant and dynamic aqueous media. This optochemical sensor was based on Oxazine 170 perchlorate (sensing material) and polydimethylsiloxane (PDMS) (protective material) thin layers. A special chemical solution was developed for the etching removal of cladding and a methodology for trapping moisture was exercised. Experimental results on dissolved ammonia detection exhibited short response time (≤10 s), low detection limit (minimum detection limit 1.4 ppm), high sensitivity, and excellent reversibility (over 99%).


  • Open Access

    Microfabricated Thin Film Impedance Sensor & AC Impedance Measurements

    by Jinsong Yu, Chung-Chiun Liu

    Thin film microfabrication technique was employed to fabricate a platinum based parallel-electrode structured impedance sensor. Electrochemical impedance spectroscopy (EIS) and equivalent circuit analysis of the small amplitude (±5 mV) AC impedance measurements (frequency range: 1 MHz to 0.1 Hz) at ambient temperature were carried out. Testing media include 0.001 M, 0.01 M, 0.1 M NaCl and KCl solutions, and alumina (~3 μm) and sand (~300 μm) particulate layers saturated with NaCl solutions with the thicknesses ranging from 0.6 mm to 8 mm in a testing cell, and the results were used to assess the effect of the thickness of the particulate layer on the conductivity of the testing solution. The calculated resistances were approximately around 20 MΩ, 4 MΩ, and 0.5 MΩ for 0.001 M, 0.01 M, and 0.1 M NaCl solutions, respectively. The presence of the sand particulates increased the impedance dramatically (6 times and 3 times for 0.001 M and 0.1 M NaCl solutions, respectively). A cell constant methodology was also developed to assess the measurement of the bulk conductivity of the electrolyte solution. The cell constant ranged from 1.2 to 0.8 and it decreased with the increase of the solution thickness.