Duangjai Nacapricha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Duangjai Nacapricha has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Kate Grudpan
Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
3 shared publicationsK. Grudpan
Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand
2 shared publicationsChanpen Karuwan
Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs.), Mahidol University, Bangkok, Thailand
1 shared publicationJuwadee Shiowatana
Department of Chemistry, Faculty of Science, Mahidol University, Bangkok, Thailand
1 shared publicationK Choden
Department of Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand
1 shared publicationK Uraisin
Department of Chemistry, Faculty of Science, Mahidol University, Rama 6 Road, Bangkok 10400, Thailand
1 shared publication
Latest Publications
- Open Access
Pulsed Amperometry for Anti-fouling of Boron-doped Diamond in Electroanalysis of β-Agonists: Application to Flow Injection for Pharmaceutical Analysis
This work presents the construction and application of boron-doped diamond(BDD) thin film electrode as sensor for the determination of three β-agonists, viz.salbutamol, terbutaline and clenbuterol. Although well-known as a chemically inertmaterial, BDD film however shows fouling in detection of these compounds using fixedpotentialmode amperometry. A suitable waveform for pulsed amperometric detection(PAD) was developed and used to determine the agonist compounds. It was seen that thedeveloped PAD significantly refreshed the BDD surface for long-term detection in flowinjection analysis. Linear working ranges were 0.5-100 μM, 1.0-100 μM and 0.5-50 μM forsalbutamol, terbutaline and clenbuterol, respectively. The developed PAD-BDD system wasapplied to successfully determine salbutamol and terbutaline in commercial pharmaceuticalproducts. The methods were validated with a capillary electrophoresis method.
Open AccessPulsed Amperometry for Anti-fouling of Boron-doped Diamond in Electroanalysis of β-Agonists: Application to Flow Injection for Pharmaceutical Analysis
This work presents the construction and application of boron-doped diamond(BDD) thin film electrode as sensor for the determination of three β-agonists, viz.salbutamol, terbutaline and clenbuterol. Although well-known as a chemically inertmaterial, BDD film however shows fouling in detection of these compounds using fixedpotentialmode amperometry. A suitable waveform for pulsed amperometric detection(PAD) was developed and used to determine the agonist compounds. It was seen that thedeveloped PAD significantly refreshed the BDD surface for long-term detection in flowinjection analysis. Linear working ranges were 0.5-100 μM, 1.0-100 μM and 0.5-50 μM forsalbutamol, terbutaline and clenbuterol, respectively. The developed PAD-BDD system wasapplied to successfully determine salbutamol and terbutaline in commercial pharmaceuticalproducts. The methods were validated with a capillary electrophoresis method.
- 1 February 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 378 (3) , 816-821
Simple and selective method for determination of iodide in pharmaceutical products by flow injection analysis using the iodine?starch reaction
This work exploited the well-known iodine–starch reaction for development of a simple flow-injection (FI) method for determination of iodide in pharmaceutical samples. Iodide in an injected zone was oxidized to iodine. A gas diffusion unit enables selective permeation of iodine through a hydrophobic membrane. Detection was made very selective for elemental iodine by employing formation of the I3 −–starch complex. The detection limit (3S/N) of the system was 1 mg I L−1. For a liquid patent medicine used for asthma treatment we suggested modification of the system. Direct injection of this sample, which contains a particularly high concentration level of iodide (ca. 9000 mg I L−1), can be achieved by coupling a dialysis unit to the FI system. This has increased the working range to 6000–10,000 mg I L−1 without employing complicated nanoliter injection.
- 1 February 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 378 (3) , 816-821
Simple and selective method for determination of iodide in pharmaceutical products by flow injection analysis using the iodine?starch reaction
This work exploited the well-known iodine–starch reaction for development of a simple flow-injection (FI) method for determination of iodide in pharmaceutical samples. Iodide in an injected zone was oxidized to iodine. A gas diffusion unit enables selective permeation of iodine through a hydrophobic membrane. Detection was made very selective for elemental iodine by employing formation of the I3 −–starch complex. The detection limit (3S/N) of the system was 1 mg I L−1. For a liquid patent medicine used for asthma treatment we suggested modification of the system. Direct injection of this sample, which contains a particularly high concentration level of iodide (ca. 9000 mg I L−1), can be achieved by coupling a dialysis unit to the FI system. This has increased the working range to 6000–10,000 mg I L−1 without employing complicated nanoliter injection.
- 1 December 2000
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 126 (1) , 121-126
Continuous and stopped flow injection for catalytic determination of total iodine in urine
This paper describes the use of flow injection (FI) techniques for the determination of iodine in urine, based on the catalytic effect of iodide in the redox reaction between Ce(IV) and As(III). The proposed procedures minimize errors in the conventional batch method arising from the reading of absorbance at a fixed time after addition of Ce(IV) reagent. Two FI systems, for the continuous and stopped modes of operation were assembled. In the continuous-FI system, a thermostated bath was used to increase the sensitivity. However this is not necessary for the stopped-FI system. The two systems are comparable in terms of sensitivity, sample throughput and detection limit. The continuous-FI and the stopped-FI exhibited detection limits (3σ) of 2.3 and 3 μg I l−1 respectively. Both systems have equal sample throughputs of 35 samples h−1. Calibration plots for both techniques are linear. The FI procedures provide very short analysis times compared to the batch procedure. Using the linear regression test, there is no significant difference between the results from the four methods, i.e., continuous-FI, stopped-FI, conventional method and ICP-MS. The proposed methods are readily applicable for automation and can be an alternative to the conventional procedure for the survey of the iodine deficiency disorder. A condition for sample digestion is also proposed to reduce the amount of chloric acid required for complete digestion. Kinetic information of the reaction can also be obtained from the stopped flow mode.
- 1 December 2000
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 126 (1) , 121-126
Continuous and stopped flow injection for catalytic determination of total iodine in urine
This paper describes the use of flow injection (FI) techniques for the determination of iodine in urine, based on the catalytic effect of iodide in the redox reaction between Ce(IV) and As(III). The proposed procedures minimize errors in the conventional batch method arising from the reading of absorbance at a fixed time after addition of Ce(IV) reagent. Two FI systems, for the continuous and stopped modes of operation were assembled. In the continuous-FI system, a thermostated bath was used to increase the sensitivity. However this is not necessary for the stopped-FI system. The two systems are comparable in terms of sensitivity, sample throughput and detection limit. The continuous-FI and the stopped-FI exhibited detection limits (3σ) of 2.3 and 3 μg I l−1 respectively. Both systems have equal sample throughputs of 35 samples h−1. Calibration plots for both techniques are linear. The FI procedures provide very short analysis times compared to the batch procedure. Using the linear regression test, there is no significant difference between the results from the four methods, i.e., continuous-FI, stopped-FI, conventional method and ICP-MS. The proposed methods are readily applicable for automation and can be an alternative to the conventional procedure for the survey of the iodine deficiency disorder. A condition for sample digestion is also proposed to reduce the amount of chloric acid required for complete digestion. Kinetic information of the reaction can also be obtained from the stopped flow mode.