Jim Schwiegerling
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jim Schwiegerling has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Edward DeHoog
Biomedical Engineering Program, University of Arizona, 1657 East Helen Street, Tucson, Arizona 85721, USA
3 shared publicationsJunoh Choi
2 shared publicationsPeng Wu
College of Optical Sciences, University of Arizona, Tucson, Arizona 85721, USA
2 shared publicationsCarmen Paleta-Toxqui
1 shared publication- Elizabeth Swan
College of Optical Sciences, University of Arizona, 1630 E University Blvd, Tucson, AZ 85719, USA
1 shared publication - Eniko T. Enikov
University of Arizona
1 shared publication
Latest Publications
- 1 December 2022
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 61 (12) , 121809-9
Remote measurement of spherocylindrical spectacle lens prescriptions
A system has been developed to measure spherocylindrical spectacle lenses. The global pandemic limited access to regular eye exams. The system bypasses this limitation by providing at-home prescription measurements. The power and orientation of the spectacle lenses are obtained with a cell phone camera, a displayed or printed target, and a magnetic stripe card. The spatially varying magnification of the lenses is calculated by examining the image captured through the lens of the target at a fixed distance. This information is then used to calculate a clinical prescription, i.e., Sph/Cyl × Axis. The system is tested with 48 single-power spherocylindrical lenses with a range of −11.25 to +4.25 D for Sph, −5.25 to −0.25 D for Cyl, and a whole range of Axis. The results are plotted in comparison with these reference prescriptions provided by a commercially available lensmeter and show good agreement. The image processing and clinical prescription calculation are discussed here.
- 1 December 2022
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 61 (12) , 121809-9
Remote measurement of spherocylindrical spectacle lens prescriptions
A system has been developed to measure spherocylindrical spectacle lenses. The global pandemic limited access to regular eye exams. The system bypasses this limitation by providing at-home prescription measurements. The power and orientation of the spectacle lenses are obtained with a cell phone camera, a displayed or printed target, and a magnetic stripe card. The spatially varying magnification of the lenses is calculated by examining the image captured through the lens of the target at a fixed distance. This information is then used to calculate a clinical prescription, i.e., Sph/Cyl × Axis. The system is tested with 48 single-power spherocylindrical lenses with a range of −11.25 to +4.25 D for Sph, −5.25 to −0.25 D for Cyl, and a whole range of Axis. The results are plotted in comparison with these reference prescriptions provided by a commercially available lensmeter and show good agreement. The image processing and clinical prescription calculation are discussed here.
- 1 June 2021
- Published by Frontiers Media SA in Advanced Optical Technologies
- Vol. 10 (3) , 143-144
Introduction to Blahnik and Schindelbeck’s Smartphone Imaging Technology and its Applications
Article Introduction to Blahnik and Schindelbeck’s Smartphone Imaging Technology and its Applications was published on June 1, 2021 in the journal Advanced Optical Technologies (volume 10, issue 3).
- 1 June 2021
- Published by Frontiers Media SA in Advanced Optical Technologies
- Vol. 10 (3) , 143-144
Introduction to Blahnik and Schindelbeck’s Smartphone Imaging Technology and its Applications
Article Introduction to Blahnik and Schindelbeck’s Smartphone Imaging Technology and its Applications was published on June 1, 2021 in the journal Advanced Optical Technologies (volume 10, issue 3).
- 1 January 2019
- Published by Optica Publishing Group
- p. MW4D.5
Simulating Optical System Performance Using Light Fields Generated from Rendering Software
The light field describes the radiance at a point from a ray coming from a particular direction. A scene’s light field is calculated with rendering software to simulate images for camera lenses with different aberrations.
- 1 January 2019
- Published by Optica Publishing Group
- p. MW4D.5
Simulating Optical System Performance Using Light Fields Generated from Rendering Software
The light field describes the radiance at a point from a ray coming from a particular direction. A scene’s light field is calculated with rendering software to simulate images for camera lenses with different aberrations.
- 13 April 2017
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 34 (5) , 726-731
Relating wavefront error, apodization, and the optical transfer function: general case
In a previous paper, a technique was developed for decomposing the incoherent optical transfer function (OTF) into a linear combination of basis functions [J. Opt. Soc. Am. A 31, 2476 (2014) [CrossRef] ]. The expansion coefficients for the OTF are directly related to wavefront error coefficients and apodization factors. This earlier work assumed rotational symmetry, so that only the on-axis wavefront error components, defocus and various orders of spherical aberration, and rotationally symmetric apodization were handled. In this paper, the technique is generalized to handle arbitrary wavefront errors and apodization. Analytic expressions for the basis functions as well as an example expansion are provided.
- 13 April 2017
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 34 (5) , 726-731
Relating wavefront error, apodization, and the optical transfer function: general case
In a previous paper, a technique was developed for decomposing the incoherent optical transfer function (OTF) into a linear combination of basis functions [J. Opt. Soc. Am. A 31, 2476 (2014) [CrossRef] ]. The expansion coefficients for the OTF are directly related to wavefront error coefficients and apodization factors. This earlier work assumed rotational symmetry, so that only the on-axis wavefront error components, defocus and various orders of spherical aberration, and rotationally symmetric apodization were handled. In this paper, the technique is generalized to handle arbitrary wavefront errors and apodization. Analytic expressions for the basis functions as well as an example expansion are provided.
- 26 July 2016
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 33 (8) , 1626-1627
Relating wavefront error, apodization, and the optical transfer function: on-axis case: reply
Efficient coding enables rapid calculation of basis functions for a linear expansion of the optical transfer function.
- 26 July 2016
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 33 (8) , 1626-1627
Relating wavefront error, apodization, and the optical transfer function: on-axis case: reply
Efficient coding enables rapid calculation of basis functions for a linear expansion of the optical transfer function.
- 20 October 2014
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 31 (11) , 2476-2483
Relating wavefront error, apodization, and the optical transfer function: on-axis case
The incoherent optical transfer function (OTF) describes contrast degradation and phase shifts of sinusoidal objects of all spatial frequencies and orientations. The OTF is calculated as either an autocorrelation of the pupil function or the Fourier transform of the point spread function. Even with fast algorithms, these calculations can be slow for a densely sampled pupil. Here, a linear expansion of the OTF is developed in which the expansion coefficients are related to the wavefront error and apodization coefficients. The advantage of such a representation is that the OTF can be quickly generated from parameters of the optical system.
- 20 October 2014
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 31 (11) , 2476-2483
Relating wavefront error, apodization, and the optical transfer function: on-axis case
The incoherent optical transfer function (OTF) describes contrast degradation and phase shifts of sinusoidal objects of all spatial frequencies and orientations. The OTF is calculated as either an autocorrelation of the pupil function or the Fourier transform of the point spread function. Even with fast algorithms, these calculations can be slow for a densely sampled pupil. Here, a linear expansion of the OTF is developed in which the expansion coefficients are related to the wavefront error and apodization coefficients. The advantage of such a representation is that the OTF can be quickly generated from parameters of the optical system.
- Open Access
Photostress Testing Device for Diagnosing Retinal Disease
Retinal diseases such as Age-Related Macular Degeneration (ARMD) affect nearly one in three elderly patients. ARMD damages the central vision photoreceptors in the fovea. The Photostress Test is a simple technique for testing for the early effects of ARMD. Here, the illumination sources in a novel self-administered Photostress Testing device were modeled for safety and distribution in illumination software. After satisfying the design constraints in the model, a prototype of the illumination system was fabricated and tested to confirm the modeling results. The resultant prototype can be used to aid in the diagnosis of retinal disease and is well within retinal safety levels.
Open AccessPhotostress Testing Device for Diagnosing Retinal Disease
Retinal diseases such as Age-Related Macular Degeneration (ARMD) affect nearly one in three elderly patients. ARMD damages the central vision photoreceptors in the fovea. The Photostress Test is a simple technique for testing for the early effects of ARMD. Here, the illumination sources in a novel self-administered Photostress Testing device were modeled for safety and distribution in illumination software. After satisfying the design constraints in the model, a prototype of the illumination system was fabricated and tested to confirm the modeling results. The resultant prototype can be used to aid in the diagnosis of retinal disease and is well within retinal safety levels.
- Open Access
- 1 August 2013
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 29 (8) , 515-516
Eye Axes and Their Relevance to Alignment of Corneal Refractive Procedures
Journal of Refractive Surgery | From the College of Optical Sciences, University of Arizona, Tucson, Arizona.Dr. Schwiegerling has no financial or proprietary interest in the materials presented herein. Correspondence: James T. Schwiegerling, PhD, College of Optical Sciences, University of Arizona, 1630 East University Boulevard, Tucson, AZ 85721. E-mail: jschwieg@u.arizona.edu Photo reprinted
- 1 August 2013
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 29 (8) , 515-516
Open AccessEye Axes and Their Relevance to Alignment of Corneal Refractive Procedures
Journal of Refractive Surgery | From the College of Optical Sciences, University of Arizona, Tucson, Arizona.Dr. Schwiegerling has no financial or proprietary interest in the materials presented herein. Correspondence: James T. Schwiegerling, PhD, College of Optical Sciences, University of Arizona, 1630 East University Boulevard, Tucson, AZ 85721. E-mail: jschwieg@u.arizona.edu Photo reprinted
- 8 August 2011
- Published by Optica Publishing Group in Optics Letters
- Vol. 36 (16) , 3076-3078
Scaling pseudo-Zernike expansion coefficients to different pupil sizes
Orthogonal polynomials are routinely used to represent complex surfaces over a specified domain. In optics, Zernike polynomials have found wide application in optical testing, wavefront sensing, and aberration theory. This set is orthogonal over the continuous unit circle matching the typical shape of optical components and pupils. A variety of techniques has been developed to scale Zernike expansion coefficients to concentric circular subregions to mimic, for example, stopping down the aperture size of an optical system. Here, similar techniques are used to rescale the expansion coefficients to new pupil sizes for a related orthogonal set: the pseudo-Zernike polynomials.
- 8 August 2011
- Published by Optica Publishing Group in Optics Letters
- Vol. 36 (16) , 3076-3078
Scaling pseudo-Zernike expansion coefficients to different pupil sizes
Orthogonal polynomials are routinely used to represent complex surfaces over a specified domain. In optics, Zernike polynomials have found wide application in optical testing, wavefront sensing, and aberration theory. This set is orthogonal over the continuous unit circle matching the typical shape of optical components and pupils. A variety of techniques has been developed to scale Zernike expansion coefficients to concentric circular subregions to mimic, for example, stopping down the aperture size of an optical system. Here, similar techniques are used to rescale the expansion coefficients to new pupil sizes for a related orthogonal set: the pseudo-Zernike polynomials.
- 15 March 2010
- Published by Optica Publishing Group in Applied Optics
- Vol. 49 (16) , D62-D68
Problems testing diffractive intraocular lenses with Shack-Hartmann sensors
Shack–Hartmann wavefront sensors have found widespread application for testing ocular aberrations. These sensors provide an accurate map of the wavefront emerging from an eye in most cases. However, there is a growing class of patients with diffractive intraocular lenses that will potentially be measured incorrectly with Shack–Hartmann devices. We explore the pitfalls of measuring diffractive lenses with this technology.
- 15 March 2010
- Published by Optica Publishing Group in Applied Optics
- Vol. 49 (16) , D62-D68
Problems testing diffractive intraocular lenses with Shack-Hartmann sensors
Shack–Hartmann wavefront sensors have found widespread application for testing ocular aberrations. These sensors provide an accurate map of the wavefront emerging from an eye in most cases. However, there is a growing class of patients with diffractive intraocular lenses that will potentially be measured incorrectly with Shack–Hartmann devices. We explore the pitfalls of measuring diffractive lenses with this technology.