Yunqian Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yunqian Zhang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Zhe Chen
School of Economics and Management, Beihang University, Beijing, China
2 shared publications Ming Cheng
School of Electrical Engineering Southeast University Nanjing 210096 People's Republic of China
1 shared publication- Weihao Hu
University of Electronic Science and Technology of China
1 shared publication - Yanting Hu
Electrical Engineering of the Institute of Art, Design and Technology, Glyndwr University, Wrexham LL11 2AW, UK
1 shared publication
Latest Publications
- Open Access
Flicker Mitigation by Speed Control of Permanent Magnet Synchronous Generator Variable-Speed Wind Turbines
Grid-connected wind turbines are fluctuating power sources that may produce flicker during continuous operation. This paper presents a simulation model of a MW-level variable speed wind turbine with a full-scale back-to-back power converter and permanent magnet synchronous generator (PMSG) developed in the simulation tool of PSCAD/EMTDC. Flicker emission of this system is investigated. The 3p (three times per revolution) power oscillation due to wind shear and tower shadow effects is the significant part in the flicker emission of variable speed wind turbines with PMSG during continuous operation. A new method of flicker mitigation by controlling the rotational speed is proposed. It smoothes the 3p active power oscillations from wind shear and tower shadow effects of the wind turbine by varying the rotational speed of the PMSG. Simulation results show that damping the 3p active power oscillation by using the flicker mitigation speed controller is an effective means for flicker mitigation of variable speed wind turbines with full-scale back-to-back power converters and PMSG during continuous operation.
Open AccessFlicker Mitigation by Speed Control of Permanent Magnet Synchronous Generator Variable-Speed Wind Turbines
Grid-connected wind turbines are fluctuating power sources that may produce flicker during continuous operation. This paper presents a simulation model of a MW-level variable speed wind turbine with a full-scale back-to-back power converter and permanent magnet synchronous generator (PMSG) developed in the simulation tool of PSCAD/EMTDC. Flicker emission of this system is investigated. The 3p (three times per revolution) power oscillation due to wind shear and tower shadow effects is the significant part in the flicker emission of variable speed wind turbines with PMSG during continuous operation. A new method of flicker mitigation by controlling the rotational speed is proposed. It smoothes the 3p active power oscillations from wind shear and tower shadow effects of the wind turbine by varying the rotational speed of the PMSG. Simulation results show that damping the 3p active power oscillation by using the flicker mitigation speed controller is an effective means for flicker mitigation of variable speed wind turbines with full-scale back-to-back power converters and PMSG during continuous operation.
- Open Access
- 1 May 2013
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 7 (3) , 191-200
Proportional resonant individual pitch control for mitigation of wind turbines loads
This study addresses the mitigation of wind turbine loads and fatigue such as blade bending moments, tilt and yaw moments etc. Currently, the wind turbine blades are normally controlled to turn collectively to limit the excess of wind power above rated wind speed conditions without any load attenuation. The individual pitch control (IPC) is a promising way to reduce the wind turbine loads. This study presents a proportional resonant (PR) IPC, which does not need the measurement of blade azimuth angle and multiple complex Coleman transformations between rotational coordinate frame and stationary coordinate frame. The new strategy can attenuate the 1 p and higher harmonics on the wind turbine blades as well as 3 p on the hub without any filters. The wind turbine code fatigue, aerodynamics, structures and turbulence is applied to a doubly fed induction generator‐based wind power generation system. The simulations are performed on the National Renewable Energy Laboratory 1.5 MW upwind reference wind turbine model. The simulation results are presented and discussed to demonstrate the capability and effectiveness of the proposed PR IPC method.
- 1 May 2013
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 7 (3) , 191-200
Open AccessProportional resonant individual pitch control for mitigation of wind turbines loads
This study addresses the mitigation of wind turbine loads and fatigue such as blade bending moments, tilt and yaw moments etc. Currently, the wind turbine blades are normally controlled to turn collectively to limit the excess of wind power above rated wind speed conditions without any load attenuation. The individual pitch control (IPC) is a promising way to reduce the wind turbine loads. This study presents a proportional resonant (PR) IPC, which does not need the measurement of blade azimuth angle and multiple complex Coleman transformations between rotational coordinate frame and stationary coordinate frame. The new strategy can attenuate the 1 p and higher harmonics on the wind turbine blades as well as 3 p on the hub without any filters. The wind turbine code fatigue, aerodynamics, structures and turbulence is applied to a doubly fed induction generator‐based wind power generation system. The simulations are performed on the National Renewable Energy Laboratory 1.5 MW upwind reference wind turbine model. The simulation results are presented and discussed to demonstrate the capability and effectiveness of the proposed PR IPC method.