Marta Šavor Novak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marta Šavor Novak has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Mario Uroš
Department of Engineering Mechanics, Faculty of Civil Engineering, University of Zagreb, 10000 Zagreb, Croatia
12 shared publications - Josip Atalić
Faculty of Civil Engineering, University of Zagreb, Zagreb, Croatia
7 shared publications - Marija Demšić
Department of Engineering Mechanics, Faculty of Civil Engineering, University of Zagreb, Zagreb, Croatia
6 shared publications - Ante Pilipović
Department of Engineering Mechanics, Faculty of Civil Engineering, University of Zagreb, 10000 Zagreb, Croatia
4 shared publications Josip Atalić
4 shared publications- Maja Baniček
Croatian Centre for Earthquake Engineering, Faculty of Civil Engineering, University of Zagreb, Zagreb, Croatia
4 shared publications
Latest Publications
- Open Access
- 7 September 2026
- Published by Springer Nature in Bulletin of Earthquake Engineering
- p. 1-35
Earthquake risk assessment of the city of Zagreb, Croatia: recent advances
- 7 September 2026
- Published by Springer Nature in Bulletin of Earthquake Engineering
- p. 1-35
Open AccessEarthquake risk assessment of the city of Zagreb, Croatia: recent advances
- Open Access
- 8 May 2026
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 30 (13) , 2874-2894
Seismic Vulnerability Assessment Methods and Models for Buildings in the West Balkan Region: A Review
- 8 May 2026
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 30 (13) , 2874-2894
Open AccessSeismic Vulnerability Assessment Methods and Models for Buildings in the West Balkan Region: A Review
- Open Access
Selection of the Optimal Intensity Measure for Unreinforced Masonry Buildings Using Vulnerability-Based Metrics
Selection of the optimal intensity measure is an important contribution to reducing the numerous uncertainties in seismic inputs within the context of performance-based earthquake engineering, especially for unreinforced masonry buildings that exhibit strong nonlinear behaviour. While traditional metrics such as efficiency, sufficiency, and practicality have been successfully used to determine optimal intensity measures for seismic demand models and fragility curves, the impact of different intensity measures on the final vulnerability curves has not been sufficiently investigated. Therefore, a new vulnerability-based metric is proposed, based on the vulnerability curve variance and its first derivative, with the aim of determining the optimal intensity measure for new vulnerability models of mid-rise unreinforced masonry buildings. Both traditional and new metrics were used to evaluate the performance of common intensity measures, using a typical unreinforced masonry building located in Zagreb, Croatia as a case study. The new metric produced intensity measure rankings in line with traditional metrics, but additionally proved effective in quantifying the impact of intensity measure choice on the final vulnerability curve, making it a reliable tool for vulnerability modelling. Average spectral acceleration and peak ground velocity were among the best performing intensity measures, confirming their use for unreinforced masonry buildings.
Open AccessSelection of the Optimal Intensity Measure for Unreinforced Masonry Buildings Using Vulnerability-Based Metrics
Selection of the optimal intensity measure is an important contribution to reducing the numerous uncertainties in seismic inputs within the context of performance-based earthquake engineering, especially for unreinforced masonry buildings that exhibit strong nonlinear behaviour. While traditional metrics such as efficiency, sufficiency, and practicality have been successfully used to determine optimal intensity measures for seismic demand models and fragility curves, the impact of different intensity measures on the final vulnerability curves has not been sufficiently investigated. Therefore, a new vulnerability-based metric is proposed, based on the vulnerability curve variance and its first derivative, with the aim of determining the optimal intensity measure for new vulnerability models of mid-rise unreinforced masonry buildings. Both traditional and new metrics were used to evaluate the performance of common intensity measures, using a typical unreinforced masonry building located in Zagreb, Croatia as a case study. The new metric produced intensity measure rankings in line with traditional metrics, but additionally proved effective in quantifying the impact of intensity measure choice on the final vulnerability curve, making it a reliable tool for vulnerability modelling. Average spectral acceleration and peak ground velocity were among the best performing intensity measures, confirming their use for unreinforced masonry buildings.
- Open Access
- 9 April 2025
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 23 (6) , 2715-2741
Seismic fragility assessment of existing masonry buildings in aggregate located in Zagreb
- 9 April 2025
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 23 (6) , 2715-2741
Open AccessSeismic fragility assessment of existing masonry buildings in aggregate located in Zagreb
- 11 December 2024
- Published by Springer Nature in Natural Hazards
- Vol. 121 (6) , 6777-6799
Enhancing earthquake disaster risk assessment: insights from pandemic circumstances, case studies, and lessons learned
- 11 December 2024
- Published by Springer Nature in Natural Hazards
- Vol. 121 (6) , 6777-6799
Enhancing earthquake disaster risk assessment: insights from pandemic circumstances, case studies, and lessons learned
- Open Access
Detailed Structural Typology of Existing Substandard Masonry and Reinforced Concrete Buildings in the City of Zagreb, Croatia
Despite significant scientific and technological advancements in earthquake engineering, earthquakes continue to cause widespread destruction of the built environment, often resulting in numerous fatalities and substantial economic losses. Southeastern Europe, which includes Croatia, is part of the Mediterranean–Trans-Asian high-seismic activity zone. This area has recently experienced a series of earthquakes which had severe consequences for both populations and economies. Notably, the types of buildings that suffered significant damage or collapse during these events still constitute a large portion of the building stock across the region. The majority of residential buildings in Croatia and neighboring areas was constructed before the adoption of modern seismic standards, indicating that a considerable part of the building stock remains highly vulnerable to earthquakes. Therefore, the main goal of this study is to identify the building types which significantly contribute to seismic risk, with the focus on Zagreb as Croatia’s largest city and the capital; collect the documentation on the structural systems and occupancy; analyze the data; and carry out the initial vulnerability assessment. This serves as a first step toward developing a new exposure and vulnerability model for Zagreb that is also applicable to all urban areas in the region with similar building stock and seismotectonic conditions.
Open AccessDetailed Structural Typology of Existing Substandard Masonry and Reinforced Concrete Buildings in the City of Zagreb, Croatia
Despite significant scientific and technological advancements in earthquake engineering, earthquakes continue to cause widespread destruction of the built environment, often resulting in numerous fatalities and substantial economic losses. Southeastern Europe, which includes Croatia, is part of the Mediterranean–Trans-Asian high-seismic activity zone. This area has recently experienced a series of earthquakes which had severe consequences for both populations and economies. Notably, the types of buildings that suffered significant damage or collapse during these events still constitute a large portion of the building stock across the region. The majority of residential buildings in Croatia and neighboring areas was constructed before the adoption of modern seismic standards, indicating that a considerable part of the building stock remains highly vulnerable to earthquakes. Therefore, the main goal of this study is to identify the building types which significantly contribute to seismic risk, with the focus on Zagreb as Croatia’s largest city and the capital; collect the documentation on the structural systems and occupancy; analyze the data; and carry out the initial vulnerability assessment. This serves as a first step toward developing a new exposure and vulnerability model for Zagreb that is also applicable to all urban areas in the region with similar building stock and seismotectonic conditions.
- Open Access
Damage Evaluation and Seismic Assessment of a Typical Historical Unreinforced Masonry Building in the Zagreb 2020 Earthquake: A Case Study—Part I
The city of Zagreb, the national capital and economic hub of Croatia, is situated in a seismically active region and hosts a significant array of historical buildings, from the medieval to Austro-Hungarian periods. These buildings possess varying but generally high degrees of vulnerability to seismic loading. This was highlighted in the Zagreb earthquake of 22 March 2020, emphasizing the need for seismic retrofitting in order to preserve this architectural heritage. In this paper, the seismic capacity of one such unreinforced masonry building is considered through a number of analysis methods, including response spectrum, pushover, and out-of-plane wall failure analyses. Given the advantages and disadvantages of the individual methods, their applicability and value in a seismic analysis is considered. Ambient vibration measurements before and after the Zagreb 2020 earthquake, used for model calibration, are also presented. Conclusions are drawn from each individual analysis and later compared. In conclusion, no single analysis method considers all relevant failure modes, and a combination of nonlinear static or dynamic analysis and out-of-plane analysis is recommended. Due to the large volume of the material, it is published in two parts, with ground motion record selection, dynamic analysis, and a comparison of the results published in part two.
Open AccessDamage Evaluation and Seismic Assessment of a Typical Historical Unreinforced Masonry Building in the Zagreb 2020 Earthquake: A Case Study—Part I
The city of Zagreb, the national capital and economic hub of Croatia, is situated in a seismically active region and hosts a significant array of historical buildings, from the medieval to Austro-Hungarian periods. These buildings possess varying but generally high degrees of vulnerability to seismic loading. This was highlighted in the Zagreb earthquake of 22 March 2020, emphasizing the need for seismic retrofitting in order to preserve this architectural heritage. In this paper, the seismic capacity of one such unreinforced masonry building is considered through a number of analysis methods, including response spectrum, pushover, and out-of-plane wall failure analyses. Given the advantages and disadvantages of the individual methods, their applicability and value in a seismic analysis is considered. Ambient vibration measurements before and after the Zagreb 2020 earthquake, used for model calibration, are also presented. Conclusions are drawn from each individual analysis and later compared. In conclusion, no single analysis method considers all relevant failure modes, and a combination of nonlinear static or dynamic analysis and out-of-plane analysis is recommended. Due to the large volume of the material, it is published in two parts, with ground motion record selection, dynamic analysis, and a comparison of the results published in part two.
- Open Access
- 28 August 2023
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 21 (13) , 5767-5808
The December 2020 magnitude (Mw) 6.4 Petrinja earthquake, Croatia: seismological aspects, emergency response and impacts
On December 29, 2020, nine months after the March Mw 5.4 Zagreb earthquake and amidst the COVID-19 lockdown, a devastating Mw 6.4 earthquake struck near the town of Petrinja, about 50 km SE from the country’s capital Zagreb. It was preceded by the Mw 4.9 foreshock from the day before. The main shock claimed 7 fatalities and caused widespread damage. Historical centers of nearby cities with invaluable heritage buildings were significantly affected as were the many residential buildings, built mainly of unreinforced masonry. Damage was observed as far as 60 km from the epicenter. This paper summarizes the seismological aspects of the Mw 6.4 Petrinja earthquake, the emergency response and the main impacts to people and buildings. The description and findings are based on the field observations and a series of post-earthquake activities led by the team of the Faculty of Civil Engineering, University of Zagreb. Typical damage to buildings and usability data are presented with examples based on 50,000 inspection results. By far the most affected were the unreinforced masonry buildings, followed by confined masonry, whereas reinforced concrete buildings were the least affected. The total direct and indirect losses are estimated to 4.8 billion EUR. The provided information represents a useful basis and impetus for improving emergency action and long-term disaster reduction plans in other regions with similar building exposure and seismotectonic settings.
- 28 August 2023
- Published by Springer Nature in Bulletin of Earthquake Engineering
- Vol. 21 (13) , 5767-5808
Open AccessThe December 2020 magnitude (Mw) 6.4 Petrinja earthquake, Croatia: seismological aspects, emergency response and impacts
On December 29, 2020, nine months after the March Mw 5.4 Zagreb earthquake and amidst the COVID-19 lockdown, a devastating Mw 6.4 earthquake struck near the town of Petrinja, about 50 km SE from the country’s capital Zagreb. It was preceded by the Mw 4.9 foreshock from the day before. The main shock claimed 7 fatalities and caused widespread damage. Historical centers of nearby cities with invaluable heritage buildings were significantly affected as were the many residential buildings, built mainly of unreinforced masonry. Damage was observed as far as 60 km from the epicenter. This paper summarizes the seismological aspects of the Mw 6.4 Petrinja earthquake, the emergency response and the main impacts to people and buildings. The description and findings are based on the field observations and a series of post-earthquake activities led by the team of the Faculty of Civil Engineering, University of Zagreb. Typical damage to buildings and usability data are presented with examples based on 50,000 inspection results. By far the most affected were the unreinforced masonry buildings, followed by confined masonry, whereas reinforced concrete buildings were the least affected. The total direct and indirect losses are estimated to 4.8 billion EUR. The provided information represents a useful basis and impetus for improving emergency action and long-term disaster reduction plans in other regions with similar building exposure and seismotectonic settings.
- Top Cited Papers
- 1 April 2021
- Published by Elsevier in International Journal of Disaster Risk Reduction
- Vol. 56
Damage classification of residential buildings in historical downtown after the ML5.5 earthquake in Zagreb, Croatia in 2020
- 1 April 2021
- Published by Elsevier in International Journal of Disaster Risk Reduction
- Vol. 56
Top Cited PapersDamage classification of residential buildings in historical downtown after the ML5.5 earthquake in Zagreb, Croatia in 2020
- Open Access
- 12 August 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (16) , 5578
Seismic Performance Assessment of an Existing RC Wall Building with Irregular Geometry: A Case-Study of a Hospital in Croatia
Buildings of strategic importance should be able to resist seismic forces in accordance with potential earthquakes that may occur at the location and remain fully operational afterwards. However, many of them were constructed before the modern principles of seismic design were known (especially regarding detailing and ductility), and therefore may be considered substandard. The first step in mitigating the seismic risk of such structures is to assess their seismic performance and, in particular, to identify their structural deficiencies. This study presents a comprehensive methodology for the seismic performance assessment of individual buildings, applied to an existing reinforced concrete (RC) hospital. This building is of an irregular layout, constructed as a structural wall system, and it is located in the seismically active region of Croatia. It includes the assessment of seismic hazards on the location, ambient noise measurements, experimental determination of structural modal parameters, creation of a detailed numerical model calibrated with experimental data, and a seismic performance assessment using various analysis methods. As a result, the building collapse mechanisms were determined and critical structural elements identified, which is the basis for future actions directed to the reduction of its risk (e.g., applications of specific measures for a target retrofit, proposal of evacuation routes and safe places inside the building, etc.).
- 12 August 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (16) , 5578
Open AccessSeismic Performance Assessment of an Existing RC Wall Building with Irregular Geometry: A Case-Study of a Hospital in Croatia
Buildings of strategic importance should be able to resist seismic forces in accordance with potential earthquakes that may occur at the location and remain fully operational afterwards. However, many of them were constructed before the modern principles of seismic design were known (especially regarding detailing and ductility), and therefore may be considered substandard. The first step in mitigating the seismic risk of such structures is to assess their seismic performance and, in particular, to identify their structural deficiencies. This study presents a comprehensive methodology for the seismic performance assessment of individual buildings, applied to an existing reinforced concrete (RC) hospital. This building is of an irregular layout, constructed as a structural wall system, and it is located in the seismically active region of Croatia. It includes the assessment of seismic hazards on the location, ambient noise measurements, experimental determination of structural modal parameters, creation of a detailed numerical model calibrated with experimental data, and a seismic performance assessment using various analysis methods. As a result, the building collapse mechanisms were determined and critical structural elements identified, which is the basis for future actions directed to the reduction of its risk (e.g., applications of specific measures for a target retrofit, proposal of evacuation routes and safe places inside the building, etc.).