Kaitlin Rooke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kaitlin Rooke has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Ralph Jasper Mobbs
Faculty of Medicine, University of New South Wales (UNSW), Sydney, Australia
2 shared publications - Ananya Chakravorty
Department of Neurosurgery, The Wollongong Hospital, Wollongong, New South Wales, Australia
1 shared publication - Ashley Lim Cha Yin
NeuroSpine Surgery Research Group (NSURG), Prince of Wales Private Hospital, Randwick 2031, Australia
1 shared publication - David Abi-Hanna
Faculty of Medicine, University of New South Wales, Randwick 2031, Australia
1 shared publication - David B. Anderson
Sydney School of Health Sciences, The University of Sydney, Sydney, Australia
1 shared publication - David Broe
Department of Orthopaedic Surgery, Prince of Wales Private Hospital, Randwick 2031, Australia
1 shared publication
Latest Publications
- Open Access
- 6 May 2024
- Published by MDPI AG in Surgical Techniques Development
- Vol. 13 (2) , 178-191
Analysing Pre-Operative Gait Patterns Using Inertial Wearable Sensors: An Observational Study of Participants Undergoing Total Hip and Knee Replacement
Background. Knee and hip arthroplasty are two of the most frequently performed procedures in orthopaedic surgery. They are associated with positive patient-reported outcomes and significant improvements in quality of life for patients. Despite this, there may be room for further progress by quantifying functional improvements with gait analysis. Our study therefore aims to characterise the disease-specific gait pattern of participants with knee and hip osteoarthritis undergoing total joint replacement using a single chest-based wearable sensor. Methods. Twenty-nine participants awaiting total hip replacement and 28 participants awaiting total knee replacement underwent three-dimensional motion analysis with inertial wearable sensors. These gait metrics were then compared with 28 healthy controls of similar ages. Differences in gait metrics were evaluated using a T-test. The participants were recruited through a single centre to participate in this cross-sectional observational study. Participants with osteoarthritis severity sufficient to warrant surgical intervention were considered for inclusion in our study. The participants were instructed to walk 15–120 m in a hospital environment while fitted with a chest-based wearable sensor. Results. In total, three domains were evaluated, including spatiotemporal, variability and asymmetry parameters. There were marked variations in the gait asymmetry parameters and step length variation in both the hip and knee osteoarthritis patients compared with the healthy controls. The magnitude of gait deterioration in terms of step length asymmetry was greater on average in the hip osteoarthritis group than the knee group. The hip osteoarthritis (+180%, p < 0.001) and knee osteoarthritis (+129%, p = 0.001) groups demonstrated marked differences in step length asymmetry. Discussion. A single chest-based sensor was found to be capable of detecting pathological gait signatures in osteoarthritis patients when compared with age-matched controls. Future studies should compare pre- and postoperative changes to disease-specific gait impairments to validate the use of wearable sensors as a clinical adjunct.
- 6 May 2024
- Published by MDPI AG in Surgical Techniques Development
- Vol. 13 (2) , 178-191
Open AccessAnalysing Pre-Operative Gait Patterns Using Inertial Wearable Sensors: An Observational Study of Participants Undergoing Total Hip and Knee Replacement
Background. Knee and hip arthroplasty are two of the most frequently performed procedures in orthopaedic surgery. They are associated with positive patient-reported outcomes and significant improvements in quality of life for patients. Despite this, there may be room for further progress by quantifying functional improvements with gait analysis. Our study therefore aims to characterise the disease-specific gait pattern of participants with knee and hip osteoarthritis undergoing total joint replacement using a single chest-based wearable sensor. Methods. Twenty-nine participants awaiting total hip replacement and 28 participants awaiting total knee replacement underwent three-dimensional motion analysis with inertial wearable sensors. These gait metrics were then compared with 28 healthy controls of similar ages. Differences in gait metrics were evaluated using a T-test. The participants were recruited through a single centre to participate in this cross-sectional observational study. Participants with osteoarthritis severity sufficient to warrant surgical intervention were considered for inclusion in our study. The participants were instructed to walk 15–120 m in a hospital environment while fitted with a chest-based wearable sensor. Results. In total, three domains were evaluated, including spatiotemporal, variability and asymmetry parameters. There were marked variations in the gait asymmetry parameters and step length variation in both the hip and knee osteoarthritis patients compared with the healthy controls. The magnitude of gait deterioration in terms of step length asymmetry was greater on average in the hip osteoarthritis group than the knee group. The hip osteoarthritis (+180%, p < 0.001) and knee osteoarthritis (+129%, p = 0.001) groups demonstrated marked differences in step length asymmetry. Discussion. A single chest-based sensor was found to be capable of detecting pathological gait signatures in osteoarthritis patients when compared with age-matched controls. Future studies should compare pre- and postoperative changes to disease-specific gait impairments to validate the use of wearable sensors as a clinical adjunct.
- Open Access
- 15 June 2019
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 20 (1) , 288
The role of wearable devices and objective gait analysis for the assessment and monitoring of patients with lumbar spinal stenosis: systematic review
The purpose of this systematic review was to evaluate the accuracy and reliability of wearable devices for objective gait measurement of Lumbar Spinal Stenosis (LSS) patients, with a focus on relevant gait metrics. Systematic searches were conducted of five electronic databases to identify studies that assessed gait metrics by wearable or portable technology. Data was collected according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) statement guidelines. Four articles were identified for inclusion in this review. The objectives, methodology and quality of the studies varied. No single gait metric was investigated in all four studies, making comparison difficult. The most relevant metrics reported included gait cycle, gait velocity, step length and cadence, which were reported in two studies. Two studies explored gait symmetry. Differences between LSS patients and normal healthy subjects are demonstrable using wearable technology. The measurements of gait cycle, cadence, step length, gait velocity, and number of steps with wearable devices can be used in the gait measurement of LSS patients for initial assessment, and objective outcomes following interventions. However, data and analysis are limited, and further studies are necessary to comment on reliability.
- 15 June 2019
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 20 (1) , 288
Open AccessThe role of wearable devices and objective gait analysis for the assessment and monitoring of patients with lumbar spinal stenosis: systematic review
The purpose of this systematic review was to evaluate the accuracy and reliability of wearable devices for objective gait measurement of Lumbar Spinal Stenosis (LSS) patients, with a focus on relevant gait metrics. Systematic searches were conducted of five electronic databases to identify studies that assessed gait metrics by wearable or portable technology. Data was collected according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) statement guidelines. Four articles were identified for inclusion in this review. The objectives, methodology and quality of the studies varied. No single gait metric was investigated in all four studies, making comparison difficult. The most relevant metrics reported included gait cycle, gait velocity, step length and cadence, which were reported in two studies. Two studies explored gait symmetry. Differences between LSS patients and normal healthy subjects are demonstrable using wearable technology. The measurements of gait cycle, cadence, step length, gait velocity, and number of steps with wearable devices can be used in the gait measurement of LSS patients for initial assessment, and objective outcomes following interventions. However, data and analysis are limited, and further studies are necessary to comment on reliability.