Kürşat Güreşci
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kürşat Güreşci has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Ahmet Aksoy
Sivas Cumhuriyet Üniversitesi
2 shared publications - Baki Hekimoğlu
SAĞLIK BİLİMLERİ ÜNİVERSİTESİ, ANKARA DIŞKAPI YILDIRIM BEYAZIT SAĞLIK UYGULAMA VE ARAŞTIRMA MERKEZ
1 shared publication - Erdem Birgi
Department of Radiology, Ankara Training and Research Hospital, University of Health Sciences, Ankara, Turkiye
1 shared publication - Hasanali Durmaz
Yıldırım Beyazıt Üniversitesi Tıp Fakültesi, Ankara Şehir Hastanesi
1 shared publication Ilteris Turk
Ataturk Sanatoryum Training & Res Hosp, Dept Thorac Surg, Ankara, Turkiye
1 shared publication- Mehmet Çetin
Ankara Etlik City Hospital, Department of Thoracic Surgery
1 shared publication
Latest Publications
- 30 July 2026
- Published by Omer Halisdemir Universitesi in Eurasian Journal of Science Engineering and Technology
- Vol. 7 (2) , 62-71
Development of a Portable Integrated Ultrasound and Gamma imaging system
Medical imaging devices that combine both the functional and anatomical modalities have proved to be highly accurate in diagnoses. Nonetheless, current SPECT-CT systems are bulky, very costly, and non-portable, restricting their use for disabled patients. A comparison was carried out using GATE/GEANT4 Monte Carlo simulation for scintillator efficiency. The experimental work used a 4×4 pixel array GAGG(Ce)+SiPM detector with SIB616/SIB1632 readout electronics and IQSP580 DAQ system. Hexagonal and pinhole collimators were thoroughly investigated. Two new algorithms for image fusion were created; these include Dynamic Alpha Blending and US-Protected Adaptive Overlay. The results show the superiority of GAGG(Ce) with 3.196 mm spatial resolution and 4.9% energy resolution, better than LYSO (3.391mm, 8.5%). Images with gamma photons were successfully acquired using phantom Tc-99m breast lesions from distances of 5 to 20 cm. Both dynamic algorithms yielded medically useful images with Method 2 having anatomical information and Method 1 with functional details. The US-SPECT device designed provides a major breakthrough in portable hybrid medical imaging, providing bedside capability for the disabled patients as well as lower radiation doses as compared to CT-based hybrid devices.
- 30 July 2026
- Published by Omer Halisdemir Universitesi in Eurasian Journal of Science Engineering and Technology
- Vol. 7 (2) , 62-71
Development of a Portable Integrated Ultrasound and Gamma imaging system
Medical imaging devices that combine both the functional and anatomical modalities have proved to be highly accurate in diagnoses. Nonetheless, current SPECT-CT systems are bulky, very costly, and non-portable, restricting their use for disabled patients. A comparison was carried out using GATE/GEANT4 Monte Carlo simulation for scintillator efficiency. The experimental work used a 4×4 pixel array GAGG(Ce)+SiPM detector with SIB616/SIB1632 readout electronics and IQSP580 DAQ system. Hexagonal and pinhole collimators were thoroughly investigated. Two new algorithms for image fusion were created; these include Dynamic Alpha Blending and US-Protected Adaptive Overlay. The results show the superiority of GAGG(Ce) with 3.196 mm spatial resolution and 4.9% energy resolution, better than LYSO (3.391mm, 8.5%). Images with gamma photons were successfully acquired using phantom Tc-99m breast lesions from distances of 5 to 20 cm. Both dynamic algorithms yielded medically useful images with Method 2 having anatomical information and Method 1 with functional details. The US-SPECT device designed provides a major breakthrough in portable hybrid medical imaging, providing bedside capability for the disabled patients as well as lower radiation doses as compared to CT-based hybrid devices.
- Open Access
- 31 December 2025
- Published by Istanbul Gelisim University in İstanbul Gelişim Üniversitesi Sağlık Bilimleri Dergisi
- No. 27,p. 1168-1173
A Rare Case of Anatomical Variation in the Middle Ear: Aberrant Internal Carotid Artery
Although variations in middle ear vascular anatomy are rare, they pose significant risks during otologic procedures. An aberrant internal carotid artery (ICA) is one such anomaly that may remain asymptomatic and undetected without the aid of imaging. A 14-year-old female presented with a one-month history of left ear pain, fullness, conductive hearing loss, and tinnitus. Initially misdiagnosed and treated for serous otitis media, she did not respond to therapy. Otomicroscopy revealed a non-pulsatile retrotympanic vascular mass. Audiometry confirmed conductive hearing loss. Temporal bone CT and MRI demonstrated a left-sided aberrant ICA protruding into the middle ear without bone erosion. The patient was managed conservatively. Aberrant ICA is typically incidental, usually occurring in adults, with a right-sided, pulsatile presentation. This pediatric case with left-sided, non-pulsatile findings highlights the risk of misdiagnosis and potential iatrogenic injury. Imaging was critical for accurate diagnosis. Imaging should be considered for persistent middle ear symptoms to avoid life-threatening surgical complications.
- 31 December 2025
- Published by Istanbul Gelisim University in İstanbul Gelişim Üniversitesi Sağlık Bilimleri Dergisi
- No. 27,p. 1168-1173
Open AccessA Rare Case of Anatomical Variation in the Middle Ear: Aberrant Internal Carotid Artery
Although variations in middle ear vascular anatomy are rare, they pose significant risks during otologic procedures. An aberrant internal carotid artery (ICA) is one such anomaly that may remain asymptomatic and undetected without the aid of imaging. A 14-year-old female presented with a one-month history of left ear pain, fullness, conductive hearing loss, and tinnitus. Initially misdiagnosed and treated for serous otitis media, she did not respond to therapy. Otomicroscopy revealed a non-pulsatile retrotympanic vascular mass. Audiometry confirmed conductive hearing loss. Temporal bone CT and MRI demonstrated a left-sided aberrant ICA protruding into the middle ear without bone erosion. The patient was managed conservatively. Aberrant ICA is typically incidental, usually occurring in adults, with a right-sided, pulsatile presentation. This pediatric case with left-sided, non-pulsatile findings highlights the risk of misdiagnosis and potential iatrogenic injury. Imaging was critical for accurate diagnosis. Imaging should be considered for persistent middle ear symptoms to avoid life-threatening surgical complications.
- 29 March 2024
- Published by Acil Tip Uzmanlari Dernegi in Journal of Emergency Medicine Case Reports
- Vol. 15 (1) , 19-22
ISOLATED CRICOID CARTILAGE FRACTURE AFTER BLUNT THORACOCERVICAL TRAUMA: A CASE REPORT
İntroduction: Although cricoid cartilage fracture is rare because of the firm and stable structure of the cricoid cartilage, it can cause fatal complications. Prompt diagnosis and rapid airway safety are incredibly vital. Case Report: A 24-year-old male patient was admitted to the emergency department due to blunt trauma to the thoracocervical region. The computed tomography taken after the first interventions detected a displaced fracture of the cricoid cartilage. Conclusion: In light of the patient's clinical findings, the patient was treated conservatively and non-surgically with close follow-up of the airway safety. Keywords: Cricoid fracture, subcutaneous emphysema, larynx trauma, thoracocervical blunt trauma, conservative treatment
- 29 March 2024
- Published by Acil Tip Uzmanlari Dernegi in Journal of Emergency Medicine Case Reports
- Vol. 15 (1) , 19-22
ISOLATED CRICOID CARTILAGE FRACTURE AFTER BLUNT THORACOCERVICAL TRAUMA: A CASE REPORT
İntroduction: Although cricoid cartilage fracture is rare because of the firm and stable structure of the cricoid cartilage, it can cause fatal complications. Prompt diagnosis and rapid airway safety are incredibly vital. Case Report: A 24-year-old male patient was admitted to the emergency department due to blunt trauma to the thoracocervical region. The computed tomography taken after the first interventions detected a displaced fracture of the cricoid cartilage. Conclusion: In light of the patient's clinical findings, the patient was treated conservatively and non-surgically with close follow-up of the airway safety. Keywords: Cricoid fracture, subcutaneous emphysema, larynx trauma, thoracocervical blunt trauma, conservative treatment
- Open Access
- 21 February 2023
- Published by Galenos Yayinevi in Thoracic Research and Practice
- Vol. 24 (1) , 34-39
Efficiency of Outsourcing Reporting in Thorax Computed Tomography Evaluation: Retrospective Analysis of 350 Thoracic Surgery Cases
Computed tomography,overlooked findings,outsourcing,radiology,thoracic surgery
- 21 February 2023
- Published by Galenos Yayinevi in Thoracic Research and Practice
- Vol. 24 (1) , 34-39
Open AccessEfficiency of Outsourcing Reporting in Thorax Computed Tomography Evaluation: Retrospective Analysis of 350 Thoracic Surgery Cases
Computed tomography,overlooked findings,outsourcing,radiology,thoracic surgery
- Open Access
- 1 April 2019
- Published by Galenos Yayinevi in Journal of Ankara University Faculty of Medicine
- Vol. 72 (1) , 76-81
Percutaneous Metallic Stenting in Malignant Biliary Obstructions: Single Center Experience
- 1 April 2019
- Published by Galenos Yayinevi in Journal of Ankara University Faculty of Medicine
- Vol. 72 (1) , 76-81
Open AccessPercutaneous Metallic Stenting in Malignant Biliary Obstructions: Single Center Experience