TSThomas A. Smith

Thomas A. Smith

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Thomas A. Smith has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Ghost frequency-time comb LiDAR in the single photon regime

    by Jeffrey M. Jaso, Binod Joshi, Thomas A. Smith, Matthew Pelton, Yanhua Shih

    We experimentally demonstrate a feasible approach to light detection and ranging for low-reflecting targets using a ghost frequency-time comb (GFC). The continuous wave (CW) output beam of a fiber ring laser with half a million cavity modes is split into two paths: one at full intensity to an analog detector near the laser source, and the other sent to the target and reflected back to a single photon avalanche diode. Using a “hybrid detection scheme” with mixed analog and single-photon detectors, we calculated the second-order temporal correlation to reveal a GFC with as few as 937 total detected photons collected over 2.5 ms. The precise spacing of comb peaks enables a least-squares fit, resulting in a 10.1 km distance estimation with a standard deviation of 7 mm. Averaging the correlation functions for seven datasets with a mean of 866 detected photons each reduces the standard deviation to 4 mm. The demonstrated precision, fast measurement rate, and low-intensity CW propagation, together with the potential insensitivity to atmospheric turbulence and background noise, make the GFC method well-suited for ranging and target tracking applications.

  • Intensity correlations of two independent lasers in a double-slit interferometer

    by Amanda L. Alley, Joshua M. Grossman, Mary F. Locke, Thomas A. Smith

    Superimposing a pair of independent lasers is considered an incoherent process due to the inability to produce stable interference. However, here we show that stable interference can be recovered from transient interference through intensity correlation measurements. We demonstrate this by utilizing a pair of independent laser beams incident on separate slits of a Young’s double-slit interferometer. This resulting stability enables the use of a pair of independent lasers in a correlation-based interferometric sensor that has the potential to be more robust to sources of phase noise, such as optical turbulence or vibrations.

  • Top Cited Papers

    Strong nanophotonic quantum squeezing exceeding 3.5 dB in a foundry-compatible Kerr microresonator

    by Yichen Shen, Ping-Yen Hsieh, Sashank Kaushik Sridhar, Samantha Feldman, You-Chia Chang, Thomas A. Smith, Avik Dutt

    Squeezed light, with its quantum noise reduction capabilities, has emerged as a powerful resource in quantum information processing and precision metrology. To reach noise reduction levels such that a quantum advantage is achieved, off-chip squeezers are typically used. The development of on-chip squeezed light sources, particularly in nanophotonic platforms, has been challenging. We report 3.7±0.2dB of directly detected nanophotonic quantum squeezing using foundry-fabricated silicon nitride (Si3N4) microrings with an inferred squeezing level of 10.2 dB on-chip. The squeezing level is robust across multiple devices and pump detunings, and is consistent with the overcoupling degree without noticeable degradation from excess classical noise. We also offer insights to mitigate thermally induced excess noise, which typically degrades squeezing, by using small-radius rings with a larger free spectral range (450 GHz) and consequently lower parametric oscillation thresholds. Our results demonstrate that Si3N4 is a viable platform for strong quantum noise reduction in a CMOS-compatible, scalable architecture.


  • Time transfer and clock synchronization with ghost frequency comb

    by Binod Joshi, Thomas A. Smith, Yanhua Shih

    We report an experimental demonstration of a time transfer and distant clock synchronization scheme based on what we have labeled as a ghost frequency comb, observed from the nonlocal correlation measurements of a laser beam. Unlike a conventional frequency comb, the laser beam used in this work does not consist of a pulse train but instead it is in a continuous-wave operation. The laser beam, consisting of half a million longitudinal cavity modes from a fiber ring laser, is split into two beams, each sent to a distant observer. In their local measurements, both observers observe constant intensity with no pulse structure present. Surprisingly, a pulse train of comb-like, ultra-narrow peaks is observed from their nonlocal correlation function measurement. This observation makes an important contribution to the field of precision spectroscopy, as we show in optical correlation-based nonlocal timing and positioning.


  • Nontrivial intensity correlation from a coherent continuous-wave laser beam

    by Binod Joshi, Thomas A. Smith, Yanhua Shih

    We report an experimental observation of nontrivial intensity correlation of a continuous-wave fiber ring laser. The laser beam consists of approximately 450 000 independent longitudinal cavity modes, each in a coherent state representing a group of identical photons. Based on Glauber's second-order coherence theory, we conclude that the nontrivial intensity correlation is the result of a randomly created and randomly paired distinguishable group of identical photons interfering with the pair itself. This result is fundamentally interesting and practically useful.


  • Multi-band interference and imaging via joint-detection of two-photon beats from thermal radiation

    by Binod Joshi, Thomas A. Smith, Yanhua Shih

    We present a theoretical discussion of multi-band two-photon interference via joint detection by “slow” detectors and extend it to a technique for multi-band ghost imaging. This technique exploits the advantage of two-photon optical beats over classical optical beats with multi-band thermal light, where the beat frequency can be resolved from intensity fluctuation correlation measurement with two relatively slow photodetectors. The underlying two-photon beats represent a two-photon interference phenomenon: a pair of randomly created and randomly paired photons interfering with the pair itself. A notable implication of the two-photon beats is that they can be turbulence-resistant, which makes our result not only of fundamental interest but also practically useful.


  • Open Access

    Turbulence-free interference induced by the turbulence itself

    by Thomas A. Smith, Yanhua Shih

    When a laser beam is incident on a double-slit interferometer without turbulence, the classic Young’s double-slit interference is present in the first-order measurement of the mean photon number (or intensity), while the second-order measurement of photon number fluctuation correlation (or intensity fluctuation correlation) yields a trivial constant. When optical turbulence is introduced, it destroys the classic interference present in the measurement of the photon number; however, two-photon interference appears in the measurement of photon number fluctuation correlation. This interesting observation means that the observed two-photon interference is not only observable through turbulence, i.e., turbulence-free, but also induced by the turbulence itself. Turbulence-free two-photon interference induced by the turbulence itself allows for interferometric sensing through strong turbulence when coherent radiation, such as a laser, is applied.


  • Two-photon X-ray ghost microscope

    by Thomas A. Smith, Zhehui Wang, Yanhua Shih

    This article presents a non-classical imaging mechanism that produces a diffraction-limited and magnified ghost image of the internal structure of an object through the measurement of intensity fluctuation correlation formed by two-photon interference. In principle, the lensless X-ray ghost imaging mechanism may achieve a spatial resolution determined by the wavelength and the angular diameter of the X-ray source, ∼λ/Δθ s , with possible reduction caused by additional optics. In addition, it has the ability to image select “slices” deep within an object, which can be used for constructing 3D view of its internal structure.


  • Turbulence-free two-photon double-slit interference with coherent and incoherent light

    by Thomas A. Smith, Yanhua Shih

    This article reports a study on a turbulence-free Young’s double-slit interferometer. When the environmental turbulence blurs out the classic Young’s double-slit interference completely, a two-photon interference pattern is still observable from the measurement of intensity or photon number fluctuation correlation. This two-photon interferometer always produces a turbulence-free interference pattern, when the double-slit interferometer is utilizing both first-order spatially incoherent light and spatially coherent light. This type of two-photon interferometer establishes new capabilities in optical observations and sensing measurements that require high sensitivity and stability.


  • From optical to X-ray ghost imaging

    by Thomas A. Smith, Yanhua Shih, Zhehui Wang, Xuan Li, Bernhard Adams, Marcel Demarteau, Robert Wagner, Junqi Xie, Lei Xia, Ren-Yuan Zhu, et al.