Georgii Aleksandrovich Airapetov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Georgii Aleksandrovich Airapetov has a total of 141 co-authors. Here are the top co-authors by number of shared publications:
- Aleksey Petrovitch Prizov
Peoples' Friendship University of Russia
12 shared publications - Nikolay Vasilievich Zagorodniy
FSBI National Medical Research Center of Traumatology and Orthopedics named after N.N. Priorov" of the Ministry of Health of Russia
10 shared publications Айрапетов Георгий Александрович
10 shared publications- Armen A. Daniliyants
Peoples’ Friendship University of Russia named after Patrice Lumumba
8 shared publications - Dmitry A. Samkovich
Peoples’ Friendship University of Russia named after Patrice Lumumba
6 shared publications - Ivan Aleksandrovich Dmitrov
City Clinical Hospital No. 31 named after Academician G.M. Savelyeva of the Moscow Healthcare Department
6 shared publications
Latest Publications
- Open Access
- 14 October 2026
- Published by ECO-Vector LLC (Publications) in Traumatology and Orthopedics of Russia
Functional versus mechanical alignment in robot-assisted total knee arthroplasty: a prospective randomized single-center trial
Background. Despite substantial advances in total knee arthroplasty (TKA), a considerable proportion of patients remain dissatisfied with surgical outcomes. One possible explanation is the discrepancy between restored joint biomechanics and the patient’s native anatomy. Functional alignment has recently emerged as a promising personalized alignment strategy facilitated by robotic-assisted technologies. The aim of the study. To compare the early clinical, functional, and radiographic outcomes of robotic-assisted total knee arthroplasty performed using functional alignment versus mechanical alignment. Methods. A prospective randomized single-center study was conducted including 103 patients with Kellgren–Lawrence grade III–IV knee osteoarthritis. Patients were allocated to robotic-assisted functional alignment (n=52) or robotic-assisted mechanical alignment (n=51). All procedures were performed using the CORI Surgical System and Anthem Total Knee System. Clinical outcomes were assessed using the Knee Society Score (KSS), Forgotten Joint Score-12 (FJS-12), and Visual Analogue Scale (VAS). Soft-tissue release requirements and radiographic parameters including HKA, LDFA, and MPTA were also evaluated. Results. At 3 months postoperatively, the functional alignment group demonstrated significantly higher KSS Knee, KSS Function, and FJS-12 scores, as well as lower VAS pain scores compared with the mechanical alignment group (p0.05). Functional alignment was associated with a reduced need for additional soft-tissue releases and a lower mean number of released structures per knee. Both groups demonstrated excellent accuracy of surgical plan execution with comparable deviations from planned alignment parameters. By 12 months, clinical outcomes became comparable between groups. Discussion. The findings suggest that functional alignment may facilitate faster early recovery by preserving native soft-tissue balance and constitutional anatomy. However, the magnitude of intergroup differences decreased over time, indicating convergence of outcomes during later stages of recovery. Conclusion. Robotic-assisted functional alignment is a safe and reproducible TKA strategy associated with improved early functional outcomes and reduced soft-tissue release requirements compared with mechanical alignment. Further multicenter studies with longer follow-up are required to determine its long-term advantages.
- 14 October 2026
- Published by ECO-Vector LLC (Publications) in Traumatology and Orthopedics of Russia
Open AccessFunctional versus mechanical alignment in robot-assisted total knee arthroplasty: a prospective randomized single-center trial
Background. Despite substantial advances in total knee arthroplasty (TKA), a considerable proportion of patients remain dissatisfied with surgical outcomes. One possible explanation is the discrepancy between restored joint biomechanics and the patient’s native anatomy. Functional alignment has recently emerged as a promising personalized alignment strategy facilitated by robotic-assisted technologies. The aim of the study. To compare the early clinical, functional, and radiographic outcomes of robotic-assisted total knee arthroplasty performed using functional alignment versus mechanical alignment. Methods. A prospective randomized single-center study was conducted including 103 patients with Kellgren–Lawrence grade III–IV knee osteoarthritis. Patients were allocated to robotic-assisted functional alignment (n=52) or robotic-assisted mechanical alignment (n=51). All procedures were performed using the CORI Surgical System and Anthem Total Knee System. Clinical outcomes were assessed using the Knee Society Score (KSS), Forgotten Joint Score-12 (FJS-12), and Visual Analogue Scale (VAS). Soft-tissue release requirements and radiographic parameters including HKA, LDFA, and MPTA were also evaluated. Results. At 3 months postoperatively, the functional alignment group demonstrated significantly higher KSS Knee, KSS Function, and FJS-12 scores, as well as lower VAS pain scores compared with the mechanical alignment group (p0.05). Functional alignment was associated with a reduced need for additional soft-tissue releases and a lower mean number of released structures per knee. Both groups demonstrated excellent accuracy of surgical plan execution with comparable deviations from planned alignment parameters. By 12 months, clinical outcomes became comparable between groups. Discussion. The findings suggest that functional alignment may facilitate faster early recovery by preserving native soft-tissue balance and constitutional anatomy. However, the magnitude of intergroup differences decreased over time, indicating convergence of outcomes during later stages of recovery. Conclusion. Robotic-assisted functional alignment is a safe and reproducible TKA strategy associated with improved early functional outcomes and reduced soft-tissue release requirements compared with mechanical alignment. Further multicenter studies with longer follow-up are required to determine its long-term advantages.
- Open Access
- 25 August 2026
- Published by ECO-Vector LLC (Publications) in N.N. Priorov Journal of Traumatology and Orthopedics
- Vol. 33 (3) , 666-673
Arthroscopic reconstruction of the anterior cruciate ligament combined with proximal tibial osteotomy: a case report
INTRODUCTION: Failed anterior cruciate ligament (ACL) reconstruction remains a significant clinical challenge in modern orthopedics, particularly in the presence of concomitant biomechanical abnormalities such as varus deformity and medial knee osteoarthritis (OA). Despite advances in surgical techniques, approximately 20–30% of patients continue to experience instability or pain after surgery, which may be attributed to various factors, including anatomical variations, improper surgical technique, and postoperative complications. This can lead to osteoarthritis progression and a significant decline in quality of life. The purpose of this work was to evaluate the clinical effectiveness of simultaneous arthroscopic ACL reconstruction and proximal tibial osteotomy (PTO) in patients with knee instability and varus deformity, as combining these two procedures is a promising approach. CASE DESCRIPTION: We present a clinical case of simultaneous arthroscopic ACL reconstruction and PTO in a 39-year-old patient with varus deformity, knee instability, and Kellgren–Lawrence grade II medial OA. The patient reported right knee instability for 10 years after a football injury and worsening pain over the past year. Preoperative scores were 60 on KOOS, 48 on KSS 1, 60 on KSS 2, and 60 mm on the visual analog scale (VAS) for pain. MRI showed grade 4 chondromalacia of the medial femoral and tibial condyles, a complete ACL tear, and varus angulation of 7.9°. The patient underwent simultaneous ACL reconstruction using hamstring tendons combined with high tibial osteotomy. At 18 months postoperatively, significant functional improvement was noted: 81 points on KOOS, 81 points on KSS 1, 90 points on KSS 2, and pain reduction to 15 mm on VAS. Repeat arthroscopy revealed grade B cartilage regeneration (Koshino classification) on the medial condyles, with preserved ACL graft function. CONCLUSION: This case demonstrates the effectiveness of combined ACL reconstruction and PTO in patients with long-term knee instability and concomitant osteoarthritis.
- 25 August 2026
- Published by ECO-Vector LLC (Publications) in N.N. Priorov Journal of Traumatology and Orthopedics
- Vol. 33 (3) , 666-673
Open AccessArthroscopic reconstruction of the anterior cruciate ligament combined with proximal tibial osteotomy: a case report
INTRODUCTION: Failed anterior cruciate ligament (ACL) reconstruction remains a significant clinical challenge in modern orthopedics, particularly in the presence of concomitant biomechanical abnormalities such as varus deformity and medial knee osteoarthritis (OA). Despite advances in surgical techniques, approximately 20–30% of patients continue to experience instability or pain after surgery, which may be attributed to various factors, including anatomical variations, improper surgical technique, and postoperative complications. This can lead to osteoarthritis progression and a significant decline in quality of life. The purpose of this work was to evaluate the clinical effectiveness of simultaneous arthroscopic ACL reconstruction and proximal tibial osteotomy (PTO) in patients with knee instability and varus deformity, as combining these two procedures is a promising approach. CASE DESCRIPTION: We present a clinical case of simultaneous arthroscopic ACL reconstruction and PTO in a 39-year-old patient with varus deformity, knee instability, and Kellgren–Lawrence grade II medial OA. The patient reported right knee instability for 10 years after a football injury and worsening pain over the past year. Preoperative scores were 60 on KOOS, 48 on KSS 1, 60 on KSS 2, and 60 mm on the visual analog scale (VAS) for pain. MRI showed grade 4 chondromalacia of the medial femoral and tibial condyles, a complete ACL tear, and varus angulation of 7.9°. The patient underwent simultaneous ACL reconstruction using hamstring tendons combined with high tibial osteotomy. At 18 months postoperatively, significant functional improvement was noted: 81 points on KOOS, 81 points on KSS 1, 90 points on KSS 2, and pain reduction to 15 mm on VAS. Repeat arthroscopy revealed grade B cartilage regeneration (Koshino classification) on the medial condyles, with preserved ACL graft function. CONCLUSION: This case demonstrates the effectiveness of combined ACL reconstruction and PTO in patients with long-term knee instability and concomitant osteoarthritis.
- 10 August 2026
- Published by Open Medical Publishing in Orthopedic Reviews
- Vol. 18
Functional alignment preserves the native Coronal Plane Alignment of the Knee phenotype while improving early clinical outcomes after robotic-assisted total knee arthroplasty
Background: Functional alignment (FA) has emerged as a personalized strategy for robotic-assisted total knee arthroplasty (ra-TKA), aiming to preserve constitutional knee anatomy and native soft-tissue balance. However, evidence directly comparing robotic-assisted FA and mechanical alignment (MA) using the same robotic platform remains limited. The aim of the study: To compare the early clinical, radiographic, and constitutional phenotype outcomes of ra-TKA performed using FA and MA. Methods: In this prospective randomized single-center study, 100 patients with primary varus knee osteoarthritis underwent primary ra-TKA using the CORI Surgical System and were randomized to the FA (n=50) or MA (n=50) group. Clinical outcomes (KSS, FJS-12, VAS), radiographic alignment (HKA, LDFA, MPTA), soft-tissue release, and postoperative CPAK phenotype preservation were evaluated over 12 months. Results: Both groups demonstrated significant postoperative improvement. At 3 months, the FA group achieved significantly higher KSS Knee, KSS Function, and FJS-12 scores together with lower VAS pain scores than the MA group (all p<0.05). These differences were no longer significant at 12 months. FA required fewer soft-tissue releases while maintaining radiographic accuracy comparable to MA. Constitutional CPAK phenotype was preserved in 82% of FA patients, whereas all mechanically aligned knees were converted to CPAK phenotype V. Native joint-line orientation and constitutional varus alignment were preserved in all FA cases. Conclusion: Robotic-assisted functional alignment provides accurate and reproducible component positioning while preserving constitutional knee phenotype and reducing soft-tissue release. Although long-term clinical outcomes were comparable, FA resulted in superior early functional recovery and represents a safe personalized alignment strategy.
- 10 August 2026
- Published by Open Medical Publishing in Orthopedic Reviews
- Vol. 18
Functional alignment preserves the native Coronal Plane Alignment of the Knee phenotype while improving early clinical outcomes after robotic-assisted total knee arthroplasty
Background: Functional alignment (FA) has emerged as a personalized strategy for robotic-assisted total knee arthroplasty (ra-TKA), aiming to preserve constitutional knee anatomy and native soft-tissue balance. However, evidence directly comparing robotic-assisted FA and mechanical alignment (MA) using the same robotic platform remains limited. The aim of the study: To compare the early clinical, radiographic, and constitutional phenotype outcomes of ra-TKA performed using FA and MA. Methods: In this prospective randomized single-center study, 100 patients with primary varus knee osteoarthritis underwent primary ra-TKA using the CORI Surgical System and were randomized to the FA (n=50) or MA (n=50) group. Clinical outcomes (KSS, FJS-12, VAS), radiographic alignment (HKA, LDFA, MPTA), soft-tissue release, and postoperative CPAK phenotype preservation were evaluated over 12 months. Results: Both groups demonstrated significant postoperative improvement. At 3 months, the FA group achieved significantly higher KSS Knee, KSS Function, and FJS-12 scores together with lower VAS pain scores than the MA group (all p<0.05). These differences were no longer significant at 12 months. FA required fewer soft-tissue releases while maintaining radiographic accuracy comparable to MA. Constitutional CPAK phenotype was preserved in 82% of FA patients, whereas all mechanically aligned knees were converted to CPAK phenotype V. Native joint-line orientation and constitutional varus alignment were preserved in all FA cases. Conclusion: Robotic-assisted functional alignment provides accurate and reproducible component positioning while preserving constitutional knee phenotype and reducing soft-tissue release. Although long-term clinical outcomes were comparable, FA resulted in superior early functional recovery and represents a safe personalized alignment strategy.
- 27 July 2026
- Published by Media Sphere Publishing Group in Pirogov Russian Journal of Surgery
- No. 7,p. 95-103
Functional alignment of knee valgus deformity in robot-assisted knee replacement: modern aspects and prospects
The authors analyze effectiveness of functional alignment in robot-assisted knee arthroplasty in patients with valgus deformity. The study demonstrates a significant improvement in clinical indicators: KSS score increase from 69.5 to 95 in the knee and from 65 to 94 in functional components, median OKS score 45 and high FJS score (93). Radiological assessment confirmed effective correction of valgus deformity: the HKA angle was corrected from 187° to 181.1°, valgus deformity decreased from 3° to 1°. Functional alignment demonstrated significant advantages compared to mechanical and modified kinematic approaches: significant less need for additional soft tissue release (15.7% versus 35.7—38.6%), better joint balance in extension (99.0% versus 86.0%) and flexion (98.0% versus 43.0%). Range of motions improved (flexion contracture decrease from preoperative 0—15° to postoperative 0—5° while maintaining flexion range at 130°). Technological advantages of robot-assisted technique include better control of implantation parameters: valgus angle of femoral component (on average 1.5°), external rotation of femoral component (0°) and tilt of tibial component (0.1°). The CPAK classification provided a personalized approach to deformity correction, taking into account individual anatomical features. Long-term analysis revealed low complication rate (1.7% of aseptic loosening cases) and efficacy of functional approach in robotic-assisted knee arthroplasty for valgus deformity.
- 27 July 2026
- Published by Media Sphere Publishing Group in Pirogov Russian Journal of Surgery
- No. 7,p. 95-103
Functional alignment of knee valgus deformity in robot-assisted knee replacement: modern aspects and prospects
The authors analyze effectiveness of functional alignment in robot-assisted knee arthroplasty in patients with valgus deformity. The study demonstrates a significant improvement in clinical indicators: KSS score increase from 69.5 to 95 in the knee and from 65 to 94 in functional components, median OKS score 45 and high FJS score (93). Radiological assessment confirmed effective correction of valgus deformity: the HKA angle was corrected from 187° to 181.1°, valgus deformity decreased from 3° to 1°. Functional alignment demonstrated significant advantages compared to mechanical and modified kinematic approaches: significant less need for additional soft tissue release (15.7% versus 35.7—38.6%), better joint balance in extension (99.0% versus 86.0%) and flexion (98.0% versus 43.0%). Range of motions improved (flexion contracture decrease from preoperative 0—15° to postoperative 0—5° while maintaining flexion range at 130°). Technological advantages of robot-assisted technique include better control of implantation parameters: valgus angle of femoral component (on average 1.5°), external rotation of femoral component (0°) and tilt of tibial component (0.1°). The CPAK classification provided a personalized approach to deformity correction, taking into account individual anatomical features. Long-term analysis revealed low complication rate (1.7% of aseptic loosening cases) and efficacy of functional approach in robotic-assisted knee arthroplasty for valgus deformity.
- Open Access
- 21 July 2026
- Published by Institute of Cytology and Genetics, SB RAS in Siberian Scientific Medical Journal
- Vol. 46 (3) , 114-120
Our experience in surgical treatment of patients with old ruptures of the Achilles tendon
Chronic Achilles tendon ruptures (CATR) remain a pressing issue in traumatology and orthopedics. The increasing incidence is associated with rising sports activity, population aging, and a higher frequency of injuries among middleaged and elderly individuals. Delayed diagnosis of CATR remains a common cause of unsatisfactory outcomes. Despite the significance of this pathology, there is still a lack of large-scale studies dedicated to CATR. The absence of unified diagnostic and treatment protocols complicates clinical decision-making and reduces the medical care quality. Aim of the study was to evaluate the efficacy of a combined approach using modified Chernavsky’s repair and flexor hallucis longus tendon transfer in the treatment of CATR with extensive defects (>5 cm). Material and methods . A retrospective clinical study included 15 patients with CATR and Achilles tendon (AT) defects exceeding 5 cm. The treatment consisted of a combination of modified Chernavsky’s repair and flexor hallucis longus tendon transfer. Results . All patients were comparable in anthropometric data. The pathology was more prevalent in men (11 males, 4 females). The age of CATR patients was 42.3 ± 6.8 years (arithmetic mean ± standard deviation), an average time from injury to surgery – 1.6 ± 1.2 months. The tendon defect length was 5.2 ± 3.7 cm, necessitating reconstructive intervention. The surgery duration was 78 ± 10.4 min. Postoperatively, a significant reduction in load-induced pain according to visual analogue scale (from 7.6 ± 1.2 to 1.4 ± 0.5, p < 0.001) and restoration of ankle motion (45.8 ± 5.3°) were observed. Functional outcomes according to American Orthopaedic Foot and Ankle Society (AOFAS) scale, Achilles Tendon Total Rupture Score (ATRS), Victorian Institute of Sport Assessment– Achilles (VISA-A) methodology were 89.4 ± 4.6, 87.2 ± 5.1, 90.6 ± 3.9 scores, respectively. Calf muscle strength recovered to 4.1 ± 0.5 points, and mobility/strength of the operated limb reached 92.5 ± 4.2 % of the unaffected side. Complications occurred in 1 patient (6.7 %). The hospitalization duration was 4.2 ± 1.5 days. Conclusions . The proposed technique demonstrated high efficacy in surgical treatment of AT ruptures with defects more than 5 cm, as evidenced by significant functional improvement and pain reduction. Thus, this method ensures reliable anatomical and functional outcomes and is recommended for clinical use in AT injuries.
- 21 July 2026
- Published by Institute of Cytology and Genetics, SB RAS in Siberian Scientific Medical Journal
- Vol. 46 (3) , 114-120
Open AccessOur experience in surgical treatment of patients with old ruptures of the Achilles tendon
Chronic Achilles tendon ruptures (CATR) remain a pressing issue in traumatology and orthopedics. The increasing incidence is associated with rising sports activity, population aging, and a higher frequency of injuries among middleaged and elderly individuals. Delayed diagnosis of CATR remains a common cause of unsatisfactory outcomes. Despite the significance of this pathology, there is still a lack of large-scale studies dedicated to CATR. The absence of unified diagnostic and treatment protocols complicates clinical decision-making and reduces the medical care quality. Aim of the study was to evaluate the efficacy of a combined approach using modified Chernavsky’s repair and flexor hallucis longus tendon transfer in the treatment of CATR with extensive defects (>5 cm). Material and methods . A retrospective clinical study included 15 patients with CATR and Achilles tendon (AT) defects exceeding 5 cm. The treatment consisted of a combination of modified Chernavsky’s repair and flexor hallucis longus tendon transfer. Results . All patients were comparable in anthropometric data. The pathology was more prevalent in men (11 males, 4 females). The age of CATR patients was 42.3 ± 6.8 years (arithmetic mean ± standard deviation), an average time from injury to surgery – 1.6 ± 1.2 months. The tendon defect length was 5.2 ± 3.7 cm, necessitating reconstructive intervention. The surgery duration was 78 ± 10.4 min. Postoperatively, a significant reduction in load-induced pain according to visual analogue scale (from 7.6 ± 1.2 to 1.4 ± 0.5, p < 0.001) and restoration of ankle motion (45.8 ± 5.3°) were observed. Functional outcomes according to American Orthopaedic Foot and Ankle Society (AOFAS) scale, Achilles Tendon Total Rupture Score (ATRS), Victorian Institute of Sport Assessment– Achilles (VISA-A) methodology were 89.4 ± 4.6, 87.2 ± 5.1, 90.6 ± 3.9 scores, respectively. Calf muscle strength recovered to 4.1 ± 0.5 points, and mobility/strength of the operated limb reached 92.5 ± 4.2 % of the unaffected side. Complications occurred in 1 patient (6.7 %). The hospitalization duration was 4.2 ± 1.5 days. Conclusions . The proposed technique demonstrated high efficacy in surgical treatment of AT ruptures with defects more than 5 cm, as evidenced by significant functional improvement and pain reduction. Thus, this method ensures reliable anatomical and functional outcomes and is recommended for clinical use in AT injuries.
- 1 July 2026
- Published by Open Medical Publishing in Orthopedic Reviews
- Vol. 18
The patient and seven surgeries: A clinical case of late-diagnosed posterior shoulder dislocations resulting in bilateral arthroplasty using 3D technology
Background: Posterior shoulder dislocations are rare and frequently misdiagnosed injuries that can lead to significant functional impairment if treatment is delayed. Chronic instability, restricted range of motion, and progressive degenerative changes often develop in neglected cases. Case presentation: We report a clinical case of a patient with bilateral posterior shoulder dislocations diagnosed 12 months after an epileptic seizure. The patient underwent multiple surgical interventions, including bilateral open reduction and defect reconstruction using custom implants. Persistent pain and limited motion after initial surgeries led to right shoulder anatomic total arthroplasty. In the postoperative period, a periprosthetic infection developed, requiring revision surgery and placement of an antibiotic-loaded spacer. During preoperative planning for the second-stage surgery, computed tomography revealed a substantial glenoid bone defect, which required the development and use of patient-specific instrumentation (PSI) and custom 3D-printed glenoid. Subsequently, anatomical total shoulder arthroplasty was performed on the left side, with autograft reconstruction of the humeral head. Results: At the latest follow-up 34 to 43 months postoperatively, the patient demonstrated excellent functional outcomes (Constant Shoulder Score: 94 right, 98 left; ASES: 93 right, 95 left) with minimal residual pain and stable implant positioning on radiographs without evidence of bone resorption or lysis. Conclusion: This case highlights the critical importance of early diagnosis and individualized treatment planning for posterior shoulder dislocations. Advanced 3D technologies, including patient-specific instrumentation and custom implants, can effectively address complex bone defects, enabling restoration of function even after multiple prior surgeries.
- 1 July 2026
- Published by Open Medical Publishing in Orthopedic Reviews
- Vol. 18
The patient and seven surgeries: A clinical case of late-diagnosed posterior shoulder dislocations resulting in bilateral arthroplasty using 3D technology
Background: Posterior shoulder dislocations are rare and frequently misdiagnosed injuries that can lead to significant functional impairment if treatment is delayed. Chronic instability, restricted range of motion, and progressive degenerative changes often develop in neglected cases. Case presentation: We report a clinical case of a patient with bilateral posterior shoulder dislocations diagnosed 12 months after an epileptic seizure. The patient underwent multiple surgical interventions, including bilateral open reduction and defect reconstruction using custom implants. Persistent pain and limited motion after initial surgeries led to right shoulder anatomic total arthroplasty. In the postoperative period, a periprosthetic infection developed, requiring revision surgery and placement of an antibiotic-loaded spacer. During preoperative planning for the second-stage surgery, computed tomography revealed a substantial glenoid bone defect, which required the development and use of patient-specific instrumentation (PSI) and custom 3D-printed glenoid. Subsequently, anatomical total shoulder arthroplasty was performed on the left side, with autograft reconstruction of the humeral head. Results: At the latest follow-up 34 to 43 months postoperatively, the patient demonstrated excellent functional outcomes (Constant Shoulder Score: 94 right, 98 left; ASES: 93 right, 95 left) with minimal residual pain and stable implant positioning on radiographs without evidence of bone resorption or lysis. Conclusion: This case highlights the critical importance of early diagnosis and individualized treatment planning for posterior shoulder dislocations. Advanced 3D technologies, including patient-specific instrumentation and custom implants, can effectively address complex bone defects, enabling restoration of function even after multiple prior surgeries.
- 18 June 2026
- Published by Media Sphere Publishing Group in Russian Journal of Archive of Pathology
- Vol. 88 (3) , 85-91
Modern morphological concepts of periprosthetic joint infection in traumatology and orthopedics
With the increase in the number of orthopedic surgeries, such as knee and hip replacement, the risk of peri-implant infection also increases. According to various registries, the number of such interventions continues to grow, making the problem of infections particularly relevant. Morphological assessment of peri-implant tissues, primarily the peri-implant membrane, has become routine practice and is used as one of the diagnostic criteria for infection. This review summarizes the main morphological changes in the peri-implant membrane formed at the bone/implant interface, presents the pathogenetic mechanisms of peri-implant osteolysis, and shows the main mechanisms of microorganism persistence in peri-implant infection.
- 18 June 2026
- Published by Media Sphere Publishing Group in Russian Journal of Archive of Pathology
- Vol. 88 (3) , 85-91
Modern morphological concepts of periprosthetic joint infection in traumatology and orthopedics
With the increase in the number of orthopedic surgeries, such as knee and hip replacement, the risk of peri-implant infection also increases. According to various registries, the number of such interventions continues to grow, making the problem of infections particularly relevant. Morphological assessment of peri-implant tissues, primarily the peri-implant membrane, has become routine practice and is used as one of the diagnostic criteria for infection. This review summarizes the main morphological changes in the peri-implant membrane formed at the bone/implant interface, presents the pathogenetic mechanisms of peri-implant osteolysis, and shows the main mechanisms of microorganism persistence in peri-implant infection.
- Open Access
- 12 June 2026
- Published by Open Medical Publishing in Orthopedic Reviews
- Vol. 18, 163038
Synovial ganglion of the wrist. Is it a common tumor or an important symptom?
Relevance: Synovial ganglia, also known as joint hernias, “fluid tumors”, synovial cysts and hygromas, despite their widespread prevalence among the world’s population, oddly enough, are still a little-studied part of hand surgery. The aim: Generalization and structuring of information on the main causes of the occurrence of synovial ganglia of the hand, their connection with damage in the structure of the ligament-articular apparatus, as well as the features of the conservative and surgical treatment. Materials and methods: A systematic literature review Results: Based on the literature review, it becomes clear that over the many years of studying the etiology and pathogenesis of ganglion cysts of the hand, research on this topic has made only limited progress, with abstracts still labeled “possible cause.” This situation can be explained more from a practical perspective: it is far more important to understand and explore new methods of diagnosing and treating an existing condition, which in most cases leads to good outcomes with minimal complications and relapses. However, the extensive data currently available on the association of this condition with damage to the ligamentous and articular apparatus of the hand, and in particular SLIL, indicate an emerging consensus on the direction of future research. Conclusion: Based on the literature review, it becomes clear that over the many years of studying the etiology and pathogenesis of ganglion cysts of the hand, research on this topic has made only limited progress, with abstracts still labeled as “possible cause” which emphasizes the need for further study of the problem.
- 12 June 2026
- Published by Open Medical Publishing in Orthopedic Reviews
- Vol. 18, 163038
Open AccessSynovial ganglion of the wrist. Is it a common tumor or an important symptom?
Relevance: Synovial ganglia, also known as joint hernias, “fluid tumors”, synovial cysts and hygromas, despite their widespread prevalence among the world’s population, oddly enough, are still a little-studied part of hand surgery. The aim: Generalization and structuring of information on the main causes of the occurrence of synovial ganglia of the hand, their connection with damage in the structure of the ligament-articular apparatus, as well as the features of the conservative and surgical treatment. Materials and methods: A systematic literature review Results: Based on the literature review, it becomes clear that over the many years of studying the etiology and pathogenesis of ganglion cysts of the hand, research on this topic has made only limited progress, with abstracts still labeled “possible cause.” This situation can be explained more from a practical perspective: it is far more important to understand and explore new methods of diagnosing and treating an existing condition, which in most cases leads to good outcomes with minimal complications and relapses. However, the extensive data currently available on the association of this condition with damage to the ligamentous and articular apparatus of the hand, and in particular SLIL, indicate an emerging consensus on the direction of future research. Conclusion: Based on the literature review, it becomes clear that over the many years of studying the etiology and pathogenesis of ganglion cysts of the hand, research on this topic has made only limited progress, with abstracts still labeled as “possible cause” which emphasizes the need for further study of the problem.
- 26 March 2026
- Published by FSPSI SCFHHRP in Acta Biomedica Scientifica
- Vol. 11 (1) , 197-204
Comparative analysis of the results of reverse shoulder arthroplasty using the deltopectoral approach with complete or partial subscapularis muscle dissection
Introduction . Indications for reverse shoulder arthroplasties (RSA) have increased since their development by Paul Grammont in 1985. The design of the endoprosthesis has been improved, significantly reducing the incidence of postoperative complications. However, the question of how to treat the subscapularis muscle (SSC muscle) during reverse shoulder arthroplasty remains open. The aim . To compare the functional and clinical outcomes in patients undergoing reverse shoulder arthroplasty performed via the deltopectoral approach with either complete or partial subscapularis muscle dissection. Materials and methods . A randomized clinical trial was conducted for evaluating the outcomes of reverse shoulder arthroplasty in 49 patients. The cohort was divided into two groups. In the first group, implantation of the reverse endoprosthesis was performed using the standard deltopectoral approach, whereas in the second group a novel surgical approach with partial subscapularis muscle dissection was employed. Clinical and functional outcomes were assessed postoperatively, and at 3 and 12 months of follow-up, using the American Shoulder and Elbow Surgeons (ASES) score and the Visual Analog Scale (VAS) for pain. Results . Patients who underwent a surgical approach with partial subscapularis muscle dissection, in the postoperative period, demonstrated better scores on the ASES scale, a greater degree of anterior flexion and less intensity of pain compared to the group of patients after standard deltopectoral approach. Conclusion . The surgical approach with partial subscapularis muscle dissection improves functional and clinical outcomes after reverse shoulder arthroplasty also it reduces the probability of joint dislocation.
- 26 March 2026
- Published by FSPSI SCFHHRP in Acta Biomedica Scientifica
- Vol. 11 (1) , 197-204
Comparative analysis of the results of reverse shoulder arthroplasty using the deltopectoral approach with complete or partial subscapularis muscle dissection
Introduction . Indications for reverse shoulder arthroplasties (RSA) have increased since their development by Paul Grammont in 1985. The design of the endoprosthesis has been improved, significantly reducing the incidence of postoperative complications. However, the question of how to treat the subscapularis muscle (SSC muscle) during reverse shoulder arthroplasty remains open. The aim . To compare the functional and clinical outcomes in patients undergoing reverse shoulder arthroplasty performed via the deltopectoral approach with either complete or partial subscapularis muscle dissection. Materials and methods . A randomized clinical trial was conducted for evaluating the outcomes of reverse shoulder arthroplasty in 49 patients. The cohort was divided into two groups. In the first group, implantation of the reverse endoprosthesis was performed using the standard deltopectoral approach, whereas in the second group a novel surgical approach with partial subscapularis muscle dissection was employed. Clinical and functional outcomes were assessed postoperatively, and at 3 and 12 months of follow-up, using the American Shoulder and Elbow Surgeons (ASES) score and the Visual Analog Scale (VAS) for pain. Results . Patients who underwent a surgical approach with partial subscapularis muscle dissection, in the postoperative period, demonstrated better scores on the ASES scale, a greater degree of anterior flexion and less intensity of pain compared to the group of patients after standard deltopectoral approach. Conclusion . The surgical approach with partial subscapularis muscle dissection improves functional and clinical outcomes after reverse shoulder arthroplasty also it reduces the probability of joint dislocation.