DDDiane M. Dickson

Diane M. Dickson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Diane M. Dickson has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The PRE‐registration podiatry: Accessible recruitment and employment (PREPARE) project: A commentary on the novel approach to the podiatry workforce crisis in Glasgow

    by Pamela Price, Paul Higgins, David Lambert, Diane M. Dickson, Ruth Barn

    The profession of podiatry is facing significant workforce challenges and urgent solutions are required to increase workforce capacity. Apprenticeship models are available in England but as yet, not available in Scotland. This paper explores the local context of the current workforce challenges and summarises a novel solution collaboratively developed in Glasgow. A collaborative initiative between NHS Greater Glasgow and Clyde and Glasgow Caledonian University developed the PRE‐registration Podiatry: Accessible Recruitment and Employment (PREPARE) Project. Creative use of vacancy savings are being used to employ a limited number of individuals on a whole‐time Band 5 Annex 21 basis at the start of their podiatry degree for the duration of their studies. Academic timetables were consolidated with no change to module or learning outcomes with candidates spending 3 days per week on academic studies and 2 days per week employed within the host podiatry service during term time. If academic milestones are achieved, substantive Band five opportunities are available once registration is achieved. This project opens opportunities for graduate level study to the support workforce and others not in a position to pursue traditional models of full‐time education. To date, two additional health boards in Scotland have adopted this model and it has the potential to be a national approach for Scotland. High applicant numbers were achieved demonstrating increased interest in podiatry from this approach. This project has the potential to have a transformative impact on educating and training the future workforce, potentially being adopted by other professions facing similar workforce challenges.


  • Open Access

    Assessing the construct validity of musculoskeletal ultrasound and the rheumatoid arthritis foot disease activity index (RADAI-F5) for managing rheumatoid foot disease

    by Anika Hoque, Martijn Steultjens, Diane M Dickson, Gordon J Hendry

    Objective: The RA foot disease activity index (RADAI-F5) is a valid, reliable and clinically feasible patient-reported outcome measure (PROM) for the measurement of RA foot disease activity. Further validation of the RADAI-F5 against musculoskeletal ultrasonography (MSUS) for foot disease activity is necessary before clinical implementation. The aim of this study was to examine the construct validity of the RADAI-F5 in relationship to MSUS and clinical examination. Methods: Participants with RA completed the RADAI-F5. MSUS was used to evaluate disease activity (synovial hypertrophy/synovitis/tenosynovitis/bursitis) and joint damage (erosion) using greyscale (GS) and power Doppler (PD) at 16 regions in each foot, including joints and soft tissues. These same regions were examined clinically for swelling and tenderness. The construct validity of the RADAI-F5 was assessed using correlation coefficients and a priori-specified hypotheses for the strength of associations. Results: Of 60 participants, 48 were female, with a mean (s.d.) age of 62.6 (9.96) years and median disease duration of 15.49 (interquartile range 6–20.5) years. Theoretically consistent associations confirming construct validity [95% CI] were observed between the RADAI-F5 and MSUS GS (0.76 [0.57, 0.82]; strong), MSUS PD (0.55 [0.35, 0.71]; moderate), MSUS-detected erosions (0.41 [0.18, 0.61]; moderate), clinical tenderness (0.52 [0.31, 0.68]; moderate) and clinical swelling (0.36 [0.13, 0.55]; weak). Conclusion: Moderate to strong correlations between RADAI-F5 and MSUS demonstrate the good measurement properties of this instrument. With greater confidence in the utility of the RADAI-F5, clinical use of this new instrument as an adjunct to the disease activity score for 28 joints (DAS-28) could help to identify RA patients at risk for poor functional and radiological outcomes.


  • Open Access

    Strain sonoelastography in asymptomatic individuals and individuals with knee osteoarthritis: an evaluation of quadriceps and patellar tendon

    by Diane M. Dickson, Stephanie L. Smith, Gordon J. Hendry

    An advanced ultrasound imaging technique, sonoelastography (SE) is used to evaluate tissue elasticity. To determine SE potential to detect pathological-related changes, and characteristics related to tendon pathology we aimed to (1) compare quadriceps and patellar tendon findings in individuals with knee osteoarthritis (KOA) and asymptomatic older adults (AC), and (2) explore associations between SE, participant characteristics (age, BMI, and leg circumference) and KOA status. 84 participants (47; KOA and 37; asymptomatic older adults) underwent SE examination of quadriceps (distal) and patellar (distal, proximal) tendon in a supine position with the knee bent at 30°. Colour score (CS) and Elasticity Ratio (ER) analysis were performed by a blinded experienced operator using Esaote Mylab 70 XVG Ultrasound equipment. Significantly reduced elasticity in the distal quadriceps (median (IQR) 2(2), 3(1), p = 0.033 for KOA and AC, respectively) and proximal patellar (3(1), 3(0), p = 0.001) tendons and more elastic distal patellar (1.50 (0.55), 1.87 (0.72), p = 0.034) tendons were observed in the KOA group. Significant associations) were identified between SE and participant BMI (Rs = − 0.249–0.750, p < 0.05) and leg circumference (Rs = − 0.260–0.903, p < 0.05). Age, BMI and KOA status, were independent explanatory variables of SE CS findings at the distal quadriceps tendon patellar tendon, proximal patellar tendon and distal patellar tendon, explaining 66%, 81% and 64% of variance, respectively. Age, BMI and KOA status were independent explanatory variables of SE ER findings at the distal patellar tendon explaining 19% of variance. Potentially clinically relevant altered tendon stiffness were observed between individuals with KOA and asymptomatic controls. Key KOA risk factors and participant characteristics explained variance in tendon stiffness. Findings provide context for future studies to investigate the potential for targeted SE detected early clinical management based on associated participant characteristics.


  • Open Access

    Patients’ and clinicians’ perspectives on the clinical utility of the Rheumatoid Arthritis Foot Disease Activity Index

    by Anika Hoque, Martijn Steultjens, Diane M. Dickson, Gordon J. Hendry

    Although patient-reported outcome measures (PROMs) are recommended in clinical practice, their application in routine care is limited. The Rheumatoid Arthritis Foot Disease Activity Index (RADAI-F5) is a validated PROM for assessing foot disease in rheumatoid arthritis (RA). To explore patient and clinician opinions and perceptions of the clinical utility of the Rheumatoid Arthritis Foot Disease Activity Index (RADAI-F5), eight RA patients and eight clinicians routinely involved in the management of RA patients participated in one semi-structured remote video-based interview. They provided their perspectives on the barriers and facilitators to clinical implementation of the RADAI-F5. Three global themes were identified; 'Feet are a priority' as the impact of RA on the feet negatively impacted upon patient quality of life. The second theme was 'Need for a clinically feasible foot PROM' as participants recognised the current lack of a clinically feasible tool to determine RA foot disease. The third global theme of ‘Implementation’ was drawn together to form two subordinate themes: ‘Facilitators to RADAI-F5 implementation’ as the tool can promote communication, guide management, help screen foot symptoms, monitor foot disease status and treatments, and promote patient education and; ‘Barriers to RADAI-F5 implementation’ as there were associated practical difficulties, including lack of appointment time, administrative burdens, IT barriers and preference for further RADAI-F5 validation using imaging. The RADAI-F5 has significant potential as a clinical tool to aid foot disease management. However, implementation challenges must be overcome before broad adoption in rheumatology clinics.


  • Intermachine Variation of Ultrasound Strain Elastographic Measures of the Quadriceps and Patellar Tendons in Healthy Participants

    by Diane M. Dickson, Henrietta O. Fawole, Gordon J. Hendry, Stephanie L. Smith

    Objectives: To evaluate intermachine variation and compare intraoperator and interoperator agreement and repeatability characteristics of 2 ultrasound (US) systems for measurements of quadriceps and patellar tendons by strain elastography (SE).Methods: Forty tendons from 20 healthy participants were investigated by operators with different experience (operator 1, 12 years of US experience and >50 SE examinations; operator 2, no US experience and 1 day of SE training). Repeated measures were performed on GE Healthcare (Waukesha, WI) and Esaote (Genoa, Italy) US systems. The percentage of agreement, Cohen κ, intraclass correlation coefficient, and correlation tests assessed agreement, repeatability, and associations of SE measures. A paired t test and Wilcoxon signed rank test assessed differences in SE measures.Results: The study participants included 5 male and 15 female volunteers (mean [range] age, 29.3 [21–39] years). Better agreement and repeatability characteristics were observed for the patellar compared to the quadriceps tendon and the color score (CS) method over the elasticity ratio (ER). Intraoperator agreement was better for the experienced operator. Intraoperator repeatability was achieved in 55% of ER (intraclass correlation coefficient, 0.40–0.91; P < .05) and 77% to 85% (κ = –0.25–1) of CS measures. Interoperator repeatability was achieved in 35% (t/z, –2.93–7.94; P < .001–.048) of all ER measures. No significant differences in proximal (z, –0.13– –0.78) and distal patellar (z, –1.52–2.26; P > .5) patellar ER measures were observed. Seventy‐four percent to 75% mean agreement (κ = 0–0.5) for CS measures comparable across both US systems was observed. Intermachine ER associations were poor (r = –0.39–0.13; P > .05), whereas greater than 70% agreement (κ = –0.87–0.53) for the CS was achieved.Conclusions: The reproducibility of knee tendon SE measurements is influenced by the operator experience, US system, and tendon site.


  • Open Access

    Reliability of ultrasound strain elastography in the assessment of the quadriceps and patellar tendon in healthy adults

    by Diane M Dickson, Henrietta O Fawole, Lisa Newcombe, Stephanie L Smith, Gordon J Hendry

    Objective: To report the intra- and inter-operator reliability of ultrasound strain elastography measures in the assessment of quadriceps and patellar tendons. Materials and methods: Forty tendons were investigated of 20 healthy volunteers. Five anatomical sites were examined and analysed by three operators of differing levels of experience. Ultrasound was performed over two measures, employing three sonoelastography measurement techniques using a GE S8 with linear probe (L6–15 MHz). The percentage of exact agreement, Cohen's kappa and ICC2,1 were performed to assess intra- and inter-operator reliability. Results: The patellar tendon is more reliably measured across all techniques compared to the quadriceps tendon, particularly the distal region. Colour scoring was the most reliable method of sonoelastography. Colour scoring intra- and inter-operator reliability was better for patella tendon sites across all operators (60–95% agreement range), and greatest for experienced operators. Elasticity index intra-operator reliability was greatest for the most experienced operator compared with the least (ICC range 0.35–0.72 and ICC 0.17–0.60). Elasticity ratio intra-operator reliability of the patella tendon was fair–excellent for the experienced operator (ICC range 0.43–0.91), excluding the mid patellar region (ICC 0.13). Poor–fair inter-operator reliability was observed for elasticity ratio (ICC range 0.0–0.54) and elasticity index (ICC range 0.0–0.57). Conclusions: Strain elastography of the patellar tendon is more reliable than the quadriceps tendon. Intra- and inter-operator reliability was better when undertaken by more experienced operators. Colour scoring was more reliable than elasticity ratio and index methods. Poor–fair intra- and inter-operator reliability of the elasticity ratio and elasticity index was observed.