AAAriani Dwi Astuti

Ariani Dwi Astuti

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ariani Dwi Astuti has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Moving Bed Biofilm Reactor (MBBR) System on Kaldnes Media for Removing Ammonia and Phosphate in Domestic Wastewater

    by Avila Alifia Permata Wiyono, Ariani Dwi Astuti, Allen Kurniawan, Ramadhani Yanidar, Suliestyah, Sarah Aphirta

    Domestic wastewater is a significant contributor to water pollution in Jakarta. Successful waste treatment using the Moving Bed Biofilm Reactor (MBBR) technology should solve this problem. N-total and phosphate removability kinetics are measured in K3 Kaldnes medium to assess MBBR performance. This research was conducted on a laboratory scale, with variations in Hydraulic Retention Time (HRT) of 4, 3, 2, and 0.75 hours, using 40% media filling. The study findings revealed that variation in HRT gave the highest removal, which was 4 hours, and this gave 89.86% removal of phosphate concentration and 86.40 removal of ammonia concentration. The Stover-Kincannon equation has the best phosphate parameter kinetics, with R 2 of 0.9992 and maximum rate kinetics of 14.45mg/L.day and 12.46 mg/day. The ammonia parameters, such as the outlet concentrations, were within the Government Regulation No. 22/2021 quality requirements of the class III river water, and phosphate was below the stipulated quality requirements. The phosphate parameter, however, complies with the quality benchmarks at the U.S. Environmental Protection Agency (2009). Overall, the reactor displays good nutrient removal kinetics, but further development is required to attain full compliance with national phosphate regulations.

  • Open Access

    Performance Evaluation and Kinetic Modeling of Modified Moving Bed Biofilm Reactor (MBBR) for Domestic Wastewater Treatment

    by Annisa Setiawati, Ariani Dwi Astuti, Allen Kurniawan, Ramadhani Yanidar, Suliestyah, Sarah Aphirta

    In an effort to mitigate the contamination of the river in DKI Jakarta, this study implemented a modified MBBR using K3 Kaldnes medium to treat domestic effluent. The kinetic model and the MBBR unit were compared in terms of the treatment of residential effluent at hydraulic retention times (HRT) of 0.75, 2, 3, and 4. Initial wastewater characterisation, reactor setup, seeding, acclimatization, and reactor operation were all part of the study procedure. The highest performance was achieved at 4 hours of HRT, with 83.78% COD removal efficiency, 78.89% BOD removal efficiency, and 83.92% TSS removal efficiency. The residence wastewater quality standards were fulfilled at 0.75 hours for COD and BOD at the outflow, however Ministerial Regulation No.68/2016 on the Environment and Forests was not met for TSS. Based on the following parameters: 65.56 mg/L COD (K s coefficient ), d13.25 day −1 (μ max coefficient), 0.39 mgMLVSS/mgCOD (Y coefficient), and 0.05 day −1 (K e coefficient), the Monod model provides the most comprehensive explanation for the MBBR process for COD removal. These findings show that MBBR is biologically very effective and kinetically well-suited for COD removal under the operating conditions.

  • Open Access

    Optimizing category-based statistical metrics for selecting global climate models in rainfall projections for Peninsular Malaysia

    by Zulfaqar Sa’ADi, Dauda Pius Awhari, Ricky Anak Kemarau, Zainura Zainon Noor, Zhang Taining, Mohamad Faizal Ahmad, Abdalmaged Salem, Gunarangini Muniandy, Mohammed Faisal Mohammed Dafalla, Wimbi Apriwanda Nursiwan, et al.

    Rainfall projections are crucial for climate impact assessments and water resource management, especially in regions like Peninsular Malaysia (PM), where climate variability has a profound effect on socioeconomic and environmental systems. This study aims to optimize category-based statistical metrics, namely, error, efficiency, correlation, composite, and others, to reduce redundancy and identify the most reliable global climate models (GCMs) for improving rainfall projection accuracy in PM. Using CHIRPS daily rainfall data and GCM outputs from the Coupled Model Intercomparison Project Phase 6 (CMIP6), a multi-filtration approach was employed to rank GCM performance based on optimized metrics. The selected metrics span five categories, namely, 7 error metrics, 5 efficiency metrics, 3 correlation metrics, 2 composite metrics, and 5 other metrics, to address a broad range of evaluation needs, ensuring a rigorous and non-redundant assessment of GCMs. A systematic selection of GCM evaluation metrics reduced redundancy by up to 64%, retaining eight key metrics. Principal component analysis (PCA) confirmed these metrics as the most representative, with the first two principal components (PCs) capturing 95.5–100% of the total variance. Using compromise programming index (CPI) and Fisher-Jenks classification, five top-performing GCMs, namely, TaiESM1 (0.5507), CMCC-ESM2 (0.6753), MRI-ESM2-0 (0.7473), CMCC-CM2-SR5 (0.8402), and EC-Earth3-Veg (1.0233), were identified, with TaiESM1 (overlap efficiency, OVL = 0.96) and CMCC-ESM2 (OVL = 0.91) most closely replicating CHIRPS rainfall, making them highly recommended for reliable climate projections. The study concludes that this optimization framework significantly enhances rainfall projection reliability, thereby supporting better-informed decision-making in climate adaptation and water resource planning. Furthermore, the methodology provides a replicable approach for improving GCM selection, particularly in regions with complex climate dynamics, advancing climate modeling for sustainable development planning.


  • Open Access

    The effect of hydraulic retention time on stabilisation unit in anaerobic – contact stabilisation (A-CST) for treating palm oil mill effluent

    by Kenannita, O W P Ajie, D Nauval, A D Astuti, A Kurniawan

    The increased use of palm oil in Indonesia has triggered an increase in the quantity of Palm Oil Mill Effluent (POME). The contents of Biochemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD), Total Suspended Solid (TSS), as well as oils and grease in palm oil mill effluent, need to be reprocessed, in accordance with the provisions of the Ministry of Environment Regulation No. 5 of 2014, concerning Wastewater Quality Standards, before being discharged into water bodies. In this study, a modification of the treatment unit involving the integration of suspended growth and attached growth in anaerobic and aerobic processes, known as Anaerobic – Contact Stabilisation (A-CST) unit, was conducted to reduce the high concentration of organic matter in POME. This modification can shorten the detention time and reduce the land usage for treatment. The objective of this research was to analyse the performance of the modified A-CST system, based on variations in the detention time and modelling the estimation of biokinetics under unsteady-state conditions, through numerical analysis, statistical tests, and model validation. The research focused on the stabilisation unit, with variations in Hydraulic Retention Time (HRT) of 6 hours, 5 hours, and 4 hours. The results of this study revealed that, the highest percentage of removal was obtained at an HRT variation of 6 hours, with a COD 88%.


  • Open Access

    Treatment of palm oil mill effluent using modified rotating biological contactor with organic loading rate variations

    by M S Adam, A S Nugrohoputri, R Rahmadi, A D Astuti, A Kurniawan

    Indonesia is the world’s largest producer of palm oil or Crude Palm Oil (CPO). Palm oil production generates Palm Oil Mill Effluent (POME), which can harm the environment, if not properly treated. Untreated POME, with high Chemical Oxygen Demand (COD) levels, can lead to environmental degradations. Its high organic content and low acidity levels can also cause water pollution. This study modified the Rotating Biological Contactor (RBC) unit to treat POME, increasing the contact surface area between POME and microorganisms. It aimed to analyse the performance of the modified RBC unit, based on variations in organic loading rate (OLR). The study was conducted at a laboratory scale, with 2, 5, and 7 kgCOD/L/day organic loads. The results of this study revealed the highest percentage of removal obtained at an OLR variation of 7 kgCOD/L/day, with a removal rate of 70% for chemical oxygen demand (COD) concentration and 57% for ammonia concentration. Based on the research, the COD removal for organic loads of 7 kgCOD/L/day and 5 kgCOD/L/day decreased to 1900 mg/L and 2600 mg/L, respectively. Thus, the modified RBC unit would be more efficient with an organic load of 7 kgCOD/L/day. However, the COD concentration still did not comply with the water quality standards. Therefore, integrating the modified RBC unit with pre-treatment units, such as coagulation-flocculation, is necessary to achieve optimal effluent concentrations.


  • Application of Dried Fungus in Textile Wastewater

    by Ariani Dwi Astuti, Yonik Meilawati Yustiani


  • Open Access

    KINERJA SUBSURFACE CONSTRUCTED WETLAND MULTYLAYER FILTRATION TIPE ALIRAN VERTIKAL DENGAN MENGGUNAKAN TANAMAN AKAR WANGI (Vetivera Zozanoides) DALAM PENYISIHAN BOD DAN COD DALAM AIR LIMBAH KANTIN

    by Ariani Dwi Astuti, Muhammad Lindu, Ramadhani Yanidar, Maria Manda Kleden

    Wastewater from the canteen is a domestic wastewater that has high concentrations of organic matter that needs to be processed before being released and not contaminating the water stream. The wastewater treatment at canteen SMA Negeri 34 Jakarta begins with collecting basin and aeration basin, and then it is pumped into two reactor that is the subsurface constructed wetland multilayers filtration type flow vertical with Vetiver Grass unit (SCW-MLF) and multilayers filtration type flow vertical unit without plants (MLF) as a control. The purpose of this study was to test the effectiveness of the vetiver grass in wastewater treatment with subsurface constructed wetland unit multilayers filtration type vertical flow with vetiver grass to fulfill effluent standards before it is released into stream water. Metodology of the study was conducted from acclimatization of plants, removal the plant to the SCW-MLF unit, and analyze the quality of wastewater. Flowrate that goes into the processing unit is 6.9615 m3/day. The detention time in SCW-MLF unit was 17.7 hours. The results showed that at steady state COD organic loading on SCW-MLF unit is 917.08 to 4126.84 kg COD/ha/day for the removal efficiency around 69.2 to 80.0%, BOD organic loading is 309.78 to 850,73 kg BOD/ha/day for the removal efficiency 61.2 to 70.8%. K value SCW-MLF unit around 0.55 to 0.71 m/day for BOD, 0.57 to 0.89 m /day for COD. The concentration of the wastewater effluent from WWTP are complied to effluent standart regulation (Pergub DKI Jakarta No. 112 Tahun 2005).