Yukan Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yukan Huang has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Hua Chen
Department of Ophthalmology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
5 shared publicationsJunjie Yang
Department of Ophthalmology, Wuhan Union Hospital, Wuhan, 430022, China
5 shared publicationsXuan Yu
Department of Ophthalmology, Wuhan Union Hospital, Wuhan, 430022, China
5 shared publicationsHui Gao
Department of Ophthalmology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
4 shared publicationsLing Jin
Department of Ophthalmology, Wuhan Union Hospital, Wuhan, 430022, China
4 shared publicationsYamin Mao
Department of Ophthalmology, Wuhan Union Hospital, Wuhan, 430022, China
3 shared publications
Latest Publications
- Open Access
- 5 June 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Capsular tension ring force line and intraocular lens angle on the impact of postoperative astigmatism in Marfan syndrome lens subluxation: a retrospective study
To investigate the influence of the angle between the tension ring force line and the intraocular lens (IOL) on residual astigmatism after lens replacement surgery in Marfan Syndrome (MFS) patients with subluxated lenses. We conducted a retrospective cohort study involving patients with MFS who presented with lens subluxation and subsequently underwent cataract surgery with implantation of a Capsular Tension Ring (CTR) and a single-focus IOL at the Ophthalmology Department of Union Hospital, Huazhong University of Science and Technology, from April 1, 2020, to April 1, 2024. The study included patients with confirmed MFS and lens subluxation. Data collected included preoperative anterior segment photographs and postoperative assessments of visual acuity. The analysis focused on the measurement of the angle between the CTR force line and the IOL's long axis (TRF-IOL Angle), as well as the ocular residual astigmatism (ORA), which was determined using vector analysis methods. The study encompassed 15 patients (25 eyes) in the final analysis. The gender distribution among the patients was 68% male and 32% female. The TRF-IOL Angle was identified as a significant factor impacting postoperative residual astigmatism. A pronounced effect was observed where a TRF-IOL Angle of less than 50 degrees was associated with increased residual astigmatism, indicating a direct relationship between the angle size and astigmatism levels. No significant association was identified for angles of 50 degrees or more, suggesting a threshold effect at this angle measurement. The angle between the CTR force line and IOL is associated with residual astigmatism after lens replacement surgery in MFS patients. Our findings suggest that the TRF-IOL Angle may be a factor associated with postoperative residual astigmatism in MFS patients. Appropriate positioning of the CTR and IOL could potentially contribute to favorable astigmatic outcomes. Trial registration: This study is retrospectively registered. We have registered this study with the Chinese Clinical Trials Registry (www.chictr.org.cn, registration number: ChiCTR2400083341).
- 5 June 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessCapsular tension ring force line and intraocular lens angle on the impact of postoperative astigmatism in Marfan syndrome lens subluxation: a retrospective study
To investigate the influence of the angle between the tension ring force line and the intraocular lens (IOL) on residual astigmatism after lens replacement surgery in Marfan Syndrome (MFS) patients with subluxated lenses. We conducted a retrospective cohort study involving patients with MFS who presented with lens subluxation and subsequently underwent cataract surgery with implantation of a Capsular Tension Ring (CTR) and a single-focus IOL at the Ophthalmology Department of Union Hospital, Huazhong University of Science and Technology, from April 1, 2020, to April 1, 2024. The study included patients with confirmed MFS and lens subluxation. Data collected included preoperative anterior segment photographs and postoperative assessments of visual acuity. The analysis focused on the measurement of the angle between the CTR force line and the IOL's long axis (TRF-IOL Angle), as well as the ocular residual astigmatism (ORA), which was determined using vector analysis methods. The study encompassed 15 patients (25 eyes) in the final analysis. The gender distribution among the patients was 68% male and 32% female. The TRF-IOL Angle was identified as a significant factor impacting postoperative residual astigmatism. A pronounced effect was observed where a TRF-IOL Angle of less than 50 degrees was associated with increased residual astigmatism, indicating a direct relationship between the angle size and astigmatism levels. No significant association was identified for angles of 50 degrees or more, suggesting a threshold effect at this angle measurement. The angle between the CTR force line and IOL is associated with residual astigmatism after lens replacement surgery in MFS patients. Our findings suggest that the TRF-IOL Angle may be a factor associated with postoperative residual astigmatism in MFS patients. Appropriate positioning of the CTR and IOL could potentially contribute to favorable astigmatic outcomes. Trial registration: This study is retrospectively registered. We have registered this study with the Chinese Clinical Trials Registry (www.chictr.org.cn, registration number: ChiCTR2400083341).
- Open Access
- 8 March 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Ocular biometry agreement among ZW-30, IOLMaster 700, and sirius in cataract patients
Accurate ocular biometry is crucial for the success of refractive cataract surgery. This study aims to assess the consistency and differences of a new biometer, the ZW-30, compared with the mainstream devices IOLMaster 700 and Sirius in patients with cataracts. A total of 307 patients with cataracts (603 eyes) were included. The anterior chamber depth (ACD), central corneal thickness (CCT), white-to-white (WTW) distance, pupil diameter (PD), flat K (K1), steep K (K2), corneal astigmatism (ΔK), total keratometry (TK), total corneal astigmatism (TCA), astigmatism axis, kappa angle (κ), axial length (AL), and lens thickness (LT) were measured using the ZW-30, IOLMaster 700, and Sirius. The consistency between devices was evaluated using Bland-Altman analysis, the correlation of parameters was assessed using Spearman correlation analysis, and inter-device agreement equations were established. Strong correlations (r ≥ 0.7) and no statistically significant differences in mean values (p > 0.05) were found for ACD, CCT, AL, LT, and anterior corneal curvature (K1/K2) among the three devices, but the 95% limits of agreement (LoA) exceeded the clinical threshold. Total corneal parameters (TK/TCA) and κ angle showed strong correlations (r ≥ 0.5) among the three devices, with significant inter-device differences in mean values (p < 0.05) and 95%LoA exceeding the clinical threshold. Corneal diameter (WTW) had a weak correlation (r = 0.48) between the ZW-30 and Sirius, and differences in PD measurement methods led to systematic bias. The ZW-30 is consistent with the IOLMaster 700 and Sirius in terms of group trends for basic biometric parameters (ACD/CCT/anterior corneal curvature), but significant individual differences exist (95%LoA exceeding the threshold). Total corneal parameters (TK/TCA) and κ angle require cross-validation with Sirius. WTW and PD are not interchangeable between devices due to differences in measurement principles. Cross-device parameter conversion should be avoided in clinical practice to ensure the accuracy of refractive surgery.
- 8 March 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessOcular biometry agreement among ZW-30, IOLMaster 700, and sirius in cataract patients
Accurate ocular biometry is crucial for the success of refractive cataract surgery. This study aims to assess the consistency and differences of a new biometer, the ZW-30, compared with the mainstream devices IOLMaster 700 and Sirius in patients with cataracts. A total of 307 patients with cataracts (603 eyes) were included. The anterior chamber depth (ACD), central corneal thickness (CCT), white-to-white (WTW) distance, pupil diameter (PD), flat K (K1), steep K (K2), corneal astigmatism (ΔK), total keratometry (TK), total corneal astigmatism (TCA), astigmatism axis, kappa angle (κ), axial length (AL), and lens thickness (LT) were measured using the ZW-30, IOLMaster 700, and Sirius. The consistency between devices was evaluated using Bland-Altman analysis, the correlation of parameters was assessed using Spearman correlation analysis, and inter-device agreement equations were established. Strong correlations (r ≥ 0.7) and no statistically significant differences in mean values (p > 0.05) were found for ACD, CCT, AL, LT, and anterior corneal curvature (K1/K2) among the three devices, but the 95% limits of agreement (LoA) exceeded the clinical threshold. Total corneal parameters (TK/TCA) and κ angle showed strong correlations (r ≥ 0.5) among the three devices, with significant inter-device differences in mean values (p < 0.05) and 95%LoA exceeding the clinical threshold. Corneal diameter (WTW) had a weak correlation (r = 0.48) between the ZW-30 and Sirius, and differences in PD measurement methods led to systematic bias. The ZW-30 is consistent with the IOLMaster 700 and Sirius in terms of group trends for basic biometric parameters (ACD/CCT/anterior corneal curvature), but significant individual differences exist (95%LoA exceeding the threshold). Total corneal parameters (TK/TCA) and κ angle require cross-validation with Sirius. WTW and PD are not interchangeable between devices due to differences in measurement principles. Cross-device parameter conversion should be avoided in clinical practice to ensure the accuracy of refractive surgery.
- Open Access
- 1 January 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-10
Comparing Refractive Prediction Accuracy of IOL Master 700 and Sirius Utilizing the Barrett Universal II Formula
Purpose: To compare the refractive-prediction error (the difference between the predicted post-operative spherical equivalent and the actual spherical equivalent) of IOLMaster 700 and Sirius when their biometric data are fed into the Barrett Universal II formula. Setting: Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China. Design: Prospective, observational, single-center, paired-eye study. Methods: 123 eyes of 93 cataract patients were enrolled. The participants ranged in age from 36 to 91 years, with a mean age of 65.38 ± 14.84 years. Axial length from IOLMaster 700 and corneal curvature, anterior-chamber depth and white-to-white from both devices were entered into the BarErett Universal II calculator to obtain predicted post-operative spherical equivalent (PRP). One week after uneventful phacoemulsification with monofocal intraocular lens implantation, manifest refraction provided the actual spherical equivalent (SE). Prediction error (ΔPRE = PRP - SE) and absolute error |ΔPRE| were primary outcomes. Results: Both devices produced positive ΔPRE, but the median was lower for IOLMaster 700 than for Sirius (0.41 D vs 0.73 D; p < 0.05). Median |ΔPRE| was also smaller for IOLMaster 700 (0.61 D vs 0.80 D; p < 0.05). Eyes within ± 0.50 D of target refraction numbered 45.5% for IOLMaster 700 versus 26.0% for Sirius (p < 0.05). Subgroup analysis showed no difference in error magnitude between long (AL > 25 mm) and normal axial-length eyes. Conclusion: Under the Barrett Universal II formula, IOLMaster 700 yields more accurate refractive predictions than Sirius, with smaller systematic drift and absolute error, irrespective of axial length. Thus, IOLMaster 700 with Barrett Universal II is the preferred biometry for superior refractive accuracy. This study offers surgeons practical guidance for improving post-operative visual outcomes and patient satisfaction.
- 1 January 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-10
Open AccessComparing Refractive Prediction Accuracy of IOL Master 700 and Sirius Utilizing the Barrett Universal II Formula
Purpose: To compare the refractive-prediction error (the difference between the predicted post-operative spherical equivalent and the actual spherical equivalent) of IOLMaster 700 and Sirius when their biometric data are fed into the Barrett Universal II formula. Setting: Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China. Design: Prospective, observational, single-center, paired-eye study. Methods: 123 eyes of 93 cataract patients were enrolled. The participants ranged in age from 36 to 91 years, with a mean age of 65.38 ± 14.84 years. Axial length from IOLMaster 700 and corneal curvature, anterior-chamber depth and white-to-white from both devices were entered into the BarErett Universal II calculator to obtain predicted post-operative spherical equivalent (PRP). One week after uneventful phacoemulsification with monofocal intraocular lens implantation, manifest refraction provided the actual spherical equivalent (SE). Prediction error (ΔPRE = PRP - SE) and absolute error |ΔPRE| were primary outcomes. Results: Both devices produced positive ΔPRE, but the median was lower for IOLMaster 700 than for Sirius (0.41 D vs 0.73 D; p < 0.05). Median |ΔPRE| was also smaller for IOLMaster 700 (0.61 D vs 0.80 D; p < 0.05). Eyes within ± 0.50 D of target refraction numbered 45.5% for IOLMaster 700 versus 26.0% for Sirius (p < 0.05). Subgroup analysis showed no difference in error magnitude between long (AL > 25 mm) and normal axial-length eyes. Conclusion: Under the Barrett Universal II formula, IOLMaster 700 yields more accurate refractive predictions than Sirius, with smaller systematic drift and absolute error, irrespective of axial length. Thus, IOLMaster 700 with Barrett Universal II is the preferred biometry for superior refractive accuracy. This study offers surgeons practical guidance for improving post-operative visual outcomes and patient satisfaction.
- Open Access
- 3 December 2025
- Published by Springer Nature in BMC Ophthalmology
- Vol. 25 (1) , 682
The influence of ocular biological parameters on visual range after implantation of extended depth of focus intraocular lens
To investigate the influence of ocular biological parameters on visual range following the implantation of extended depth of focus intraocular lens (EDOF I
- 3 December 2025
- Published by Springer Nature in BMC Ophthalmology
- Vol. 25 (1) , 682
Open AccessThe influence of ocular biological parameters on visual range after implantation of extended depth of focus intraocular lens
To investigate the influence of ocular biological parameters on visual range following the implantation of extended depth of focus intraocular lens (EDOF I
- Open Access
- 11 November 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-8
Predicting accuracy of spherical equivalent after cataract surgery using the online Zcalc calculator for toric IOLs
Compare Zcalc with other formulas on spherical equivalent prediction errors (PE) and explore the relationship between PE and ocular parameters. Optimize 709 IOL power calculation. 114 eyes with age-related cataract and preoperative regular corneal astigmatism of more than 1.5D were included. They underwent cataract surgery followed by implantation of a toric intraocular lens (Zeiss Torbi 709 M) calculated by Zcalc formula. The prediction errors of spherical equivalent (SE) were analysed 3 months post-surgery. The refractive prediction errors of Zcalc, Barrett Universal II, Kane, and K6 formulas were 0.07 ± 0.63D, − 0.36 ± 0.65D, − 0.41 ± 0.67D, and − 0.31 ± 0.66D, respectively. Statistically significant difference were observed between Zcalc and other formulas. The Zcalc was prone to positive deviation, Barrett Universal II, Kane and K6 were prone to negative deviation. When the axial length is greater than 29.0 mm, the prediction errors of Kane is higher, and prone to negative deviation. Prediction errors of Zcalc are small in all eyes and prone to positive deviation. For more accurate prediction, we recommend Barrett Universal II formula for 709 IOL power calculation.
- 11 November 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-8
Open AccessPredicting accuracy of spherical equivalent after cataract surgery using the online Zcalc calculator for toric IOLs
Compare Zcalc with other formulas on spherical equivalent prediction errors (PE) and explore the relationship between PE and ocular parameters. Optimize 709 IOL power calculation. 114 eyes with age-related cataract and preoperative regular corneal astigmatism of more than 1.5D were included. They underwent cataract surgery followed by implantation of a toric intraocular lens (Zeiss Torbi 709 M) calculated by Zcalc formula. The prediction errors of spherical equivalent (SE) were analysed 3 months post-surgery. The refractive prediction errors of Zcalc, Barrett Universal II, Kane, and K6 formulas were 0.07 ± 0.63D, − 0.36 ± 0.65D, − 0.41 ± 0.67D, and − 0.31 ± 0.66D, respectively. Statistically significant difference were observed between Zcalc and other formulas. The Zcalc was prone to positive deviation, Barrett Universal II, Kane and K6 were prone to negative deviation. When the axial length is greater than 29.0 mm, the prediction errors of Kane is higher, and prone to negative deviation. Prediction errors of Zcalc are small in all eyes and prone to positive deviation. For more accurate prediction, we recommend Barrett Universal II formula for 709 IOL power calculation.
- Open Access
- 13 December 2022
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 9, 1075693
Evaluation value of subjective visual quality examination on surgical indications of the early cataracts based on objective scatter index values
Aim: To evaluate the subjective visual functions of early cataracts patients and assess their surgical indications.Methods: Eyes were separated into a control group (Group A without cataract) and two early cataracts groups (Group B with 2.0 ≤ OSI < 3.0 and Group C with 3.0 ≤ OSI < 4.0). The objective scatter index (OSI), modulation transfer function cut-off frequency (MTF cut-off), and Strehl ratio (SR) values were applied to measure objective visual functions. The contrast sensitivity (CS) and scores of the questionnaires (QOL and VF-14) characterized subjective visual functions. Above visual functions were compared among three groups. Postoperative visual functions in Group B and C were analyzed to assess the outcome of surgery.Results: Ninety two subjects (126 eyes) were included in the study. All objective visual function in Group B were significantly better than Group C (all P < 0.01), but worse than Group A (all P < 0.01). Except for 1.5 c/d CS, subjective visual function in Group A were significantly better than Group B and C (all P < 0.05), but there was no significant differences between Group B and C. As for eyes that underwent surgery in Group B and C, all visual functions significantly improved after surgery (P < 0.05), except for 1.5 c/d CS in Group C. There were no significant differences among the three groups after surgery.Conclusion: The subjective visual function can be impaired in early cataracts patients with OSI < 3.0, whose objective visual functions were statistically better than patients with OSI ≥ 3.0. These patients can benefit equally from surgery as patients with OSI ≥ 3.0. Subjective visual functions can be used as surgical indications for these patients.
- 13 December 2022
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 9, 1075693
Open AccessEvaluation value of subjective visual quality examination on surgical indications of the early cataracts based on objective scatter index values
Aim: To evaluate the subjective visual functions of early cataracts patients and assess their surgical indications.Methods: Eyes were separated into a control group (Group A without cataract) and two early cataracts groups (Group B with 2.0 ≤ OSI < 3.0 and Group C with 3.0 ≤ OSI < 4.0). The objective scatter index (OSI), modulation transfer function cut-off frequency (MTF cut-off), and Strehl ratio (SR) values were applied to measure objective visual functions. The contrast sensitivity (CS) and scores of the questionnaires (QOL and VF-14) characterized subjective visual functions. Above visual functions were compared among three groups. Postoperative visual functions in Group B and C were analyzed to assess the outcome of surgery.Results: Ninety two subjects (126 eyes) were included in the study. All objective visual function in Group B were significantly better than Group C (all P < 0.01), but worse than Group A (all P < 0.01). Except for 1.5 c/d CS, subjective visual function in Group A were significantly better than Group B and C (all P < 0.05), but there was no significant differences between Group B and C. As for eyes that underwent surgery in Group B and C, all visual functions significantly improved after surgery (P < 0.05), except for 1.5 c/d CS in Group C. There were no significant differences among the three groups after surgery.Conclusion: The subjective visual function can be impaired in early cataracts patients with OSI < 3.0, whose objective visual functions were statistically better than patients with OSI ≥ 3.0. These patients can benefit equally from surgery as patients with OSI ≥ 3.0. Subjective visual functions can be used as surgical indications for these patients.
- Open Access
- 1 December 2021
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 10 (14) , 6
Changes in Meibum Lipid Composition With Ocular Demodex Infestation
Purpose: The purpose of this study was to understand the impact of Demodex infection in the lipid component of meibum in patients. Methods: The meibum samples were collected from four groups of subjects: (1) Demodex-negative with non-MGD (D−M−; n = 10); (2) Demodex-positive with non-MGD (D+M−; n = 10); (3) Demodex-negative with MGD (D−M+; n = 10); and (4) Demodex-positive with MGD (D+M+; n = 10). A liquid chromatography–mass spectrometry (LC-MS) system consisting of ultra-performance liquid chromatography and a Q Exactive high-resolution mass spectrometer was used for lipids separation and detection. Results: Compared with the D−M− group, the D+M− group had lower levels of phosphatidylcholines (PCs) and lysophosphatidylcholines (LPCs) and higher levels of phosphatidylethanolamines (PEs). Compared with the D−M+ group, the levels of sphingomyelins (SMs) and PCs in the D+M+ group were decreased, whereas the levels of (O-acyl)-ω-hydroxy fatty acids (OAHFAs), ceramides (CERs), LPCs, and diacylglycerols (DGs) were significantly increased. Triacylglycerols (TGs), DGs, CERs, and OAHFAs were decreased in D−M+ group, whereas levels of PEs, phosphatidylinositols, and phosphatidylglycerols were increased in meibum obtained from the D−M+ group compared with those in the D−M− group. TGs, SMs, CERs, and PEs were decreased in the D+M+ group, whereas levels of LPCs, LPEs, PCs, and PEs were increased in meibum from the D−M+ group compared with those in the D+M− group. Conclusions: To the best of our knowledge, this is the first study to assess the changes in meibum from patients with ocular Demodex infestation. The significant increase of OAHFAs in the Demodex-positive group suggest that OAHFAs may be associated with the progress of ocular Demodex infections. Translational Relevance: OAHFAs could be a potential new therapeutic target for ocular Demodex infestation.
- 1 December 2021
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 10 (14) , 6
Open AccessChanges in Meibum Lipid Composition With Ocular Demodex Infestation
Purpose: The purpose of this study was to understand the impact of Demodex infection in the lipid component of meibum in patients. Methods: The meibum samples were collected from four groups of subjects: (1) Demodex-negative with non-MGD (D−M−; n = 10); (2) Demodex-positive with non-MGD (D+M−; n = 10); (3) Demodex-negative with MGD (D−M+; n = 10); and (4) Demodex-positive with MGD (D+M+; n = 10). A liquid chromatography–mass spectrometry (LC-MS) system consisting of ultra-performance liquid chromatography and a Q Exactive high-resolution mass spectrometer was used for lipids separation and detection. Results: Compared with the D−M− group, the D+M− group had lower levels of phosphatidylcholines (PCs) and lysophosphatidylcholines (LPCs) and higher levels of phosphatidylethanolamines (PEs). Compared with the D−M+ group, the levels of sphingomyelins (SMs) and PCs in the D+M+ group were decreased, whereas the levels of (O-acyl)-ω-hydroxy fatty acids (OAHFAs), ceramides (CERs), LPCs, and diacylglycerols (DGs) were significantly increased. Triacylglycerols (TGs), DGs, CERs, and OAHFAs were decreased in D−M+ group, whereas levels of PEs, phosphatidylinositols, and phosphatidylglycerols were increased in meibum obtained from the D−M+ group compared with those in the D−M− group. TGs, SMs, CERs, and PEs were decreased in the D+M+ group, whereas levels of LPCs, LPEs, PCs, and PEs were increased in meibum from the D−M+ group compared with those in the D+M− group. Conclusions: To the best of our knowledge, this is the first study to assess the changes in meibum from patients with ocular Demodex infestation. The significant increase of OAHFAs in the Demodex-positive group suggest that OAHFAs may be associated with the progress of ocular Demodex infections. Translational Relevance: OAHFAs could be a potential new therapeutic target for ocular Demodex infestation.
- Open Access
- 4 October 2021
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 62 (13) , 11
Hyperkeratinization and Proinflammatory Cytokine Expression in Meibomian Glands Induced byStaphylococcus aureus
Purpose: This exploratory study aimed to investigate the morphological and pathological alterations of the meibomian gland (MG) with the Staphylococcus aureus crude extracts (SACEs) treatment. Methods: Mouse MG explants were cultured and differentiated with or without SACEs for 48 hours. Explant's viability and cell death were determined by thiazolyl blue tetrazolium bromide (MTT) assay and TUNEL assay. MG morphology was observed by Hematoxylin and Eosin staining. Lipid droplet production was detected by Nile Red staining and LipidTox immunostaining. The pro-inflammatory cytokines were detected by ELISA. The relative gene and protein expression in MG explants was determined via quantitative RT-PCR, immunostaining, and immunoblotting. The components of the SACEs were analyzed by immunoblotting and silver staining. Results: Our findings demonstrated that the SACEs treatment induced overexpression of keratin 1 (Krt1) in the ducts and acini of MG explants, accompanied by a decrease in viability and an increase in cell death in explants. Furthermore, the SACEs treatment dose-dependently increased the levels of TNF-α, IL-1β, and IL-6 in MG explants. The SACEs treatment induced activation of the nuclear factor kappa B (NF-κB) and AIM2 (absent in melanoma 2)/ASC (apoptosis-associated speck-like protein containing a caspase recruitment domain) inflammasome signaling pathway in explants. Further investigation showed expression of the key adipogenesis-related molecule peroxisome proliferator-activated receptor γ was decreased after SACEs treatment. However, no change was found in the lipid synthesis of MG explants after treatment with the SACEs. Staphylococcal enterotoxins B (SEB) was detected in the SACEs. SEB induced the overexpression of Krt1 and IL-1β in ducts and acini of MG explants. Conclusions: Our findings confirm that Staphylococcus aureus induced hyperkeratinization and pro-inflammatory cytokines expression in MG explants ducts and acini. These effects might be mediated by SEB. Activation of the NF-κB and AIM2/ASC signaling pathway is involved in this process.
- 4 October 2021
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 62 (13) , 11
Open AccessHyperkeratinization and Proinflammatory Cytokine Expression in Meibomian Glands Induced byStaphylococcus aureus
Purpose: This exploratory study aimed to investigate the morphological and pathological alterations of the meibomian gland (MG) with the Staphylococcus aureus crude extracts (SACEs) treatment. Methods: Mouse MG explants were cultured and differentiated with or without SACEs for 48 hours. Explant's viability and cell death were determined by thiazolyl blue tetrazolium bromide (MTT) assay and TUNEL assay. MG morphology was observed by Hematoxylin and Eosin staining. Lipid droplet production was detected by Nile Red staining and LipidTox immunostaining. The pro-inflammatory cytokines were detected by ELISA. The relative gene and protein expression in MG explants was determined via quantitative RT-PCR, immunostaining, and immunoblotting. The components of the SACEs were analyzed by immunoblotting and silver staining. Results: Our findings demonstrated that the SACEs treatment induced overexpression of keratin 1 (Krt1) in the ducts and acini of MG explants, accompanied by a decrease in viability and an increase in cell death in explants. Furthermore, the SACEs treatment dose-dependently increased the levels of TNF-α, IL-1β, and IL-6 in MG explants. The SACEs treatment induced activation of the nuclear factor kappa B (NF-κB) and AIM2 (absent in melanoma 2)/ASC (apoptosis-associated speck-like protein containing a caspase recruitment domain) inflammasome signaling pathway in explants. Further investigation showed expression of the key adipogenesis-related molecule peroxisome proliferator-activated receptor γ was decreased after SACEs treatment. However, no change was found in the lipid synthesis of MG explants after treatment with the SACEs. Staphylococcal enterotoxins B (SEB) was detected in the SACEs. SEB induced the overexpression of Krt1 and IL-1β in ducts and acini of MG explants. Conclusions: Our findings confirm that Staphylococcus aureus induced hyperkeratinization and pro-inflammatory cytokines expression in MG explants ducts and acini. These effects might be mediated by SEB. Activation of the NF-κB and AIM2/ASC signaling pathway is involved in this process.
- Open Access
- 31 July 2020
- Published by Wolters Kluwer Health in Medicine
- Vol. 99 (31) , e21494
Real dynamic assessment of tear film optical quality for monitoring and early prevention of dry eye
To evaluate real dynamic assessment of tear film optical quality for monitoring and prevention of dry eye. Right eyes of 62 normal and 39 dry eye subjects were included. Dynamic measurement of objective scatter index (OSI) was performed by using the Optical Quality Analysis System II (OQAS II), correlation coefficient between OSI and time (CCOT) was calculated. According to whether the CCOT was significantly ascending, normal and dry eye groups were further subdivided for comparison. By using Scheimpflug-Placido topographer, non-invasive tear break-up time (NITBUT) was recorded, and a 2-dimensional precorneal tear film map was reconstructed and divided into central, middle, and peripheral corneal zones, distribution of tear break-up spots in the 3 corneal zones were analyzed. The numbers of tear break-up spots were higher in all the 3 corneal zones of the dry eye subjects (P < .01), when compared with the normal subjects. The Dry Eye subjects with ascending CCOT had the shortest NITBUT (P < .001–.034) and the most tear break-up spots over the whole cornea (P < .001–.044). Between the dry eye subjects with non-ascending CCOT and those with ascending CCOT, difference of tear break-up spots was found significant only in the peripheral corneal zone (P < .01). Non-ascending and ascending CCOT of dry eye patients reflect different stability of tear film. Real dynamic assessment of tear film optical quality is potential for monitoring and early prevention of dry eye.
- 31 July 2020
- Published by Wolters Kluwer Health in Medicine
- Vol. 99 (31) , e21494
Open AccessReal dynamic assessment of tear film optical quality for monitoring and early prevention of dry eye
To evaluate real dynamic assessment of tear film optical quality for monitoring and prevention of dry eye. Right eyes of 62 normal and 39 dry eye subjects were included. Dynamic measurement of objective scatter index (OSI) was performed by using the Optical Quality Analysis System II (OQAS II), correlation coefficient between OSI and time (CCOT) was calculated. According to whether the CCOT was significantly ascending, normal and dry eye groups were further subdivided for comparison. By using Scheimpflug-Placido topographer, non-invasive tear break-up time (NITBUT) was recorded, and a 2-dimensional precorneal tear film map was reconstructed and divided into central, middle, and peripheral corneal zones, distribution of tear break-up spots in the 3 corneal zones were analyzed. The numbers of tear break-up spots were higher in all the 3 corneal zones of the dry eye subjects (P < .01), when compared with the normal subjects. The Dry Eye subjects with ascending CCOT had the shortest NITBUT (P < .001–.034) and the most tear break-up spots over the whole cornea (P < .001–.044). Between the dry eye subjects with non-ascending CCOT and those with ascending CCOT, difference of tear break-up spots was found significant only in the peripheral corneal zone (P < .01). Non-ascending and ascending CCOT of dry eye patients reflect different stability of tear film. Real dynamic assessment of tear film optical quality is potential for monitoring and early prevention of dry eye.
- 14 October 2019
- Published by Springer Nature in Current Medical Science
- Vol. 39 (5) , 800-809
Intense Pulsed Light Therapy for Patients with Meibomian Gland Dysfunction and Ocular Demodex Infestation
To observe the clinical changes of meibomian gland dysfunctipn (MGD) and ocular Demodex infestation after intense pulsed light (IPL) treatment to further examine the mechanism of IPL treating patients with MGD and ocular Demodex infestation. The medical records of 25 patients (49 eyes) with MGD treated with IPL, were retrospectively examined to determine outcomes. Associated ocular-surface parameters (ocular surface disease index, OSDI; lipid layer thickness, LLT; noninvasive first breakup time, NIF-BUT; noninvasive average breakup time, NIAvg-BUT; tear film breakup area, TBUA; Schirmer I Test, SIT; corneal fluorescein staining, CFS), eyelid margin abnormalities, meibum quality and expressibility, MG morphological parameters (macrostructure and microstructure), and the number of Demodex infestation were examined before and after treatment. The MG microstructure and the Demodex infestation were examined via in vivo confocal microscopy (IVCM). The results showed that there were statistically significant differences in associated ocular-surface parameters (all PP=0.065). Eyelid margin abnormalities, meibum quality and expressibility obviously improved in upper and lower eyelid after IPL treatment (all PP=0.002) and lower eyelid (P=0.001) after IPL treatment. The nine parameters of MG microstructure in upper and lower eyelid all distinctly improved after IPL treatment (all PDemodex mites on the upper lid margin (6.59±7.16 to 3.12±3.81/9 eyelashes) and lower lid margin (2.55±2.11 to 1.29±1.53/9 eyelashes) significantly reduced after IPL treatment (all PDemodex eradication rate was 20% (8/40) in upper lid margin and 34.15% (14/41) in lower lid margin. These findings indicate that IPL shows great therapeutic potential for patients of MGD and ocular Demodex infestation.
- 14 October 2019
- Published by Springer Nature in Current Medical Science
- Vol. 39 (5) , 800-809
Intense Pulsed Light Therapy for Patients with Meibomian Gland Dysfunction and Ocular Demodex Infestation
To observe the clinical changes of meibomian gland dysfunctipn (MGD) and ocular Demodex infestation after intense pulsed light (IPL) treatment to further examine the mechanism of IPL treating patients with MGD and ocular Demodex infestation. The medical records of 25 patients (49 eyes) with MGD treated with IPL, were retrospectively examined to determine outcomes. Associated ocular-surface parameters (ocular surface disease index, OSDI; lipid layer thickness, LLT; noninvasive first breakup time, NIF-BUT; noninvasive average breakup time, NIAvg-BUT; tear film breakup area, TBUA; Schirmer I Test, SIT; corneal fluorescein staining, CFS), eyelid margin abnormalities, meibum quality and expressibility, MG morphological parameters (macrostructure and microstructure), and the number of Demodex infestation were examined before and after treatment. The MG microstructure and the Demodex infestation were examined via in vivo confocal microscopy (IVCM). The results showed that there were statistically significant differences in associated ocular-surface parameters (all PP=0.065). Eyelid margin abnormalities, meibum quality and expressibility obviously improved in upper and lower eyelid after IPL treatment (all PP=0.002) and lower eyelid (P=0.001) after IPL treatment. The nine parameters of MG microstructure in upper and lower eyelid all distinctly improved after IPL treatment (all PDemodex mites on the upper lid margin (6.59±7.16 to 3.12±3.81/9 eyelashes) and lower lid margin (2.55±2.11 to 1.29±1.53/9 eyelashes) significantly reduced after IPL treatment (all PDemodex eradication rate was 20% (8/40) in upper lid margin and 34.15% (14/41) in lower lid margin. These findings indicate that IPL shows great therapeutic potential for patients of MGD and ocular Demodex infestation.