AKAnne Kelso

Anne Kelso

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Anne Kelso has a total of 93 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Physical Activity Research through the Lense of Equity: Insights from Germany and Switzerland

    by Susanne Kobel, Claudia Niessner, Petra Wagner, Cornelia Herbert, Lukas Streese, Anne Kelso, Katja Siefken, Christina Niermann

    Regular physical activity benefits physical and mental health, yet many individuals remain insufficiently active and spend substantial time of their day sedentary, particularly those with low socioeconomic position (SEP). Consequently, disadvantaged groups face higher burdens of obesity and non-communicable diseases. SEP does not directly cause poor health but rather represents a “risk of risks,” shaped by structural, social, and environmental disadvantages. Vulnerable groups are also less likely to be reached by preventive interventions, creating inequities in both exposure to health risks and access to health-promoting resources. Using the authors’ own research projects as examples, this article examines how current exercise and health science research addresses health equity and includes vulnerable populations. Epidemiological evidence reveals persistent social inequalities in children’s motor development and physical activity, while school-based programmes often struggle to engage families with low socioeconomic position (SEP), resulting in greater benefits for more advantaged groups. Similarly, interventions targeting vulnerable populations can be tailored to specific needs and settings, but challenges related to recruitment, participation, and long-term implementation remain. Overall, the projects suggest that health inequalities are still insufficiently addressed and may, in some cases, be inadvertently reinforced by current research and intervention practices.

  • Insights into Physical Activity and Fitness of Older Adults in Swiss Residential Care Facilities: A Cross-Sectional Study

    by Caroline Yvonne Tanner, Anita Schwarz, Heinrich Steffen, Anne Kelso

    Objectives: Older adults in residential care facilities (RCFs) often experience physical and cognitive decline. This study aimed to (a) describe physical activity (PA) levels and fitness in this population and (b) identify factors associated with PA behavior. Methods: This cross-sectional analysis used baseline data from the pilot non-randomized controlled study ”„Bliib fit - mach mit!“ in residential care facilities“ conducted in Switzerland. Wrist-worn accelerometers (GENEActiv) measured sedentary time and PA (light, moderate, vigorous) over seven days, summarized as daily medians, interquartile ranges, and bout durations. Physical fitness was assessed using the Short Physical Performance Battery (SPPB), 2 Minutes Walking Test (2MWT), and handgrip strength. Linear regressions identified predictors of light and moderate PA. Key Results: Thirty-one participants were included (74% women; mean age: 83±8.8 years; mean Charlson Comorbidity Index: 5.6±1.7). Mean SPPB was 6.7±2.9. In the 2MWT, men walked 100.6±29.9 m and women 96.4±25.9 m; handgrip strength was 28.7±6.4 kg in men and 19.9±4.2 kg in women. Participants spent 86% of waking time sedentary, 12.4% in light, and 1.6% in moderate PA. The 2MWT showed the strongest association with PA (adjusted R² = 41.3% moderate PA, 31.2% light PA). Conclusion: Adults in Swiss RCFs were of advanced age with high comorbidity and high sedentary time. Routine fitness screening may help identify elderly with low PA. These findings underscore the importance of reducing sedentary time and promoting PA among RCF residents more broadly, potentially supported by improved physical fitness. Key Words: Accelerometry, Long-Term Care, Exercise, Sedentary Behavior

  • Healthy Ageing: Measuring and Maintaining Functional Ability

    by Anne Kelso, Eling D. de Bruin

    Healthy ageing is defined by the World Health Organization as “the process of developing and maintaining the functional ability that enables well-being in older age” (9, 10). This definition, which underpins the UN Decade of Healthy Ageing (2021-2030), shifts the focus from the absence of disease to what people can be and do as they grow older. Functional ability reflects an individual’s intrinsic capacity, the environment, and the interaction between them. Maintaining or improving functional ability is therefore a central challenge for clinicians, researchers and practitioners in exercise and rehabilitation.

  • Open Access

    Compatibility of physical education curricula with physical literacy across 40 European countries

    by J. Carl, H. Goss, S. Lundvall, I. Pavlova, B. Algurén, B. Antala, G. Bartle, J. Birch, V. Black, A.S. Bryant, et al.


  • Open Access

    High inter-observer reliability in standardized ultrasound measurements of subcutaneous adipose tissue in children aged three to six years

    by A. Kelso, W. Müller, A. Fürhapter-Rieger, M. Sengeis, H. Ahammer, J. M. Steinacker

    A procedure to measure subcutaneous adipose (SAT) using brightness-mode ultrasound has recently been standardized and applied to various groups of adults including underweight, overweight and obese adults. High reliability of this procedure was found in each of the examined groups. The purpose of this study was to determine inter-observer reliability of the standardized brightness-mode ultrasound measurement of uncompressed SAT in three to six-year-old children. Three experienced observers independently captured the ultrasound images at the eight standardized measurement sites in each of the 20 children and evaluated their images using an interactive software that detects the SAT contour and automatically measures multiple thicknesses in each image; the mean of these represents SAT thickness at a given site. The children were aged 4.9 ± 1.0 years; their body mass index ranged from 13.6–17.7 kgm− 2. Sound speed was set to 1450 ms− 1 for SAT. SAT thickness sums with fibrous structures included (DI) ranged from 25.7–86.4 mm, mean DI was 48.1 ± 15.5 mm. For DI, resulting from 160 measurements by each observer, the intra-class correlation coefficient was 0.998 (95% confidence interval 0.980–0.999), standard error of the estimate was 1.1 mm, and 95% limits of agreement were within ±2.1 mm. The median difference in DI was 0.8 mm, i.e. about 1.9% of mean DI. Inter-observer results in children are comparable to previously described high reliability in adults. This method, which provides a technical thickness measurement accuracy of about 0.1 to 0.2 mm, enables monitoring of subcutaneous adipose tissue in children with a similarly high reliability as was obtained in adults previously. German Institute of Medical Documentation and Information, German Clinical Trials Register (DRKS) ID: DRKS00010089; Date 24/02/2016.


  • Open Access

    Ultrasound measurements of subcutaneous adipose tissue thickness show sexual dimorphism in children of three to five years of age

    by Anne Kelso, Katharina Vogel, Jürgen M. Steinacker

    Aim A standard approach to measure subcutaneous adipose tissue (SAT) using ultrasound has proved successful in adults, but has not been studied in children. This study addressed that gap in children aged 3‐5 years. Methods In autumn 2016, 24 preschools in Southwest Germany, recruited via mail, agreed to take part in this study and 274 children (51.4% boys) with a mean age of 4.6 ±0.7 years participated in measurements of SAT and anthropometry. Differences in measurements were explored between the sexes and anthropometric predictors of mean SAT thickness were identified. Intra‐observer reliability for ultrasound measurements of SAT was also assessed. Results The mean SAT thickness showed significant differences between the boys and girls (5.3 ±2.0mm and 6.3 ±2.0mm, respectively, p<0.01). The children's body mass, height and sex explained 66% of the variance in the mean SAT thickness, as SAT was larger with a higher body mass, a smaller stature and in girls. Intra‐observer reliability resulted in an intra‐class correlation coefficient of 0.994 (p<0.01) with a 95% confidence interval of 0.983‐0.998. Conclusion SAT thickness differed between boys and girls with a mean age of 4.6 years. Intra‐observer reliability was excellent. This standardised approach enabled high‐precision measurements of SAT in a paediatric population.


  • Assessment of subcutaneous adipose tissue using ultrasound in highly trained junior rowers

    by Anne Kelso, Emese Trájer, Katja Machus, Gunnar Treff, Wolfram Müller, Jürgen M. Steinacker

    Introduction: There is a large variety of body fat (BF) measurements, which differ in validity and reliability. The aim of this study was to measure subcutaneous adipose tissue (SAT) using ultrasound (US) in highly trained junior rowers in a field setting, establish fat patterning profiles, and compare the profiles between male and female athletes. Skinfold thickness (SKF) measurements were also taken and compared to US measurements. Methods: Sixteen athletes participated. US measurements were taken at eight sites and reported as a sum of SAT (D): D-Excl (without embedded structures) and D-Incl (including embedded structures). SKF was measured at three sites and reported as a sum of adipose tissue thickness (SUMSKF). Results: Mean SAT thickness (D-Incl) was 27.6 +/- 12.4 mm for males and 65.5 +/- 11.8 mm for females. Females had significantly more embedded structures than males (P = .016). Significant correlations were found (P < .001, r = 0.92) comparing SUMSKF to DIncl and between SKF and US measurements at the thigh site (P < .001, r = 0.86). Conclusion: US is a suitable tool to measure BF in the field testing of athletes and enables measurements of SAT with an accuracy and reliability not reached before. The sum of thicknesses (D-Incl or D-Excl) can be used to represent subcutaneous fat based on accurate measurements of uncompressed SAT thicknesses.