Maria Stella Baccillieri
Research Subjects
Maria Stella Baccillieri has a total of 175 co-authors. Here are the top co-authors by number of shared publications:
Pietro Turrini
Hospital P. Cosma, Camposampiero
6 shared publicationsRoberto Verlato
Electrophysiology Unit, P. Cosma Hospital, Camposampiero, Italy
5 shared publications- Emanuele Bertaglia
Department of Cardiac Thoracic Vascular Sciences and Public Health, University of Padua, 35128 Padua, Italy
4 shared publications - Giulio Molon
Division of Cardiology, IRCCS Sacro Cuore-Don Calabria Hospital, Negrar, Verona, Italy
3 shared publications R. Verlato
Ospedale P. Cosma, Camposampiero, Italy
3 shared publications- Roberto Verlato
Hospital P. Cosma, Camposampiero
3 shared publications
Latest Publications
- Open Access
- 10 September 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (18) , 4086
Impact of COVID-19 Pandemic on Remote Monitoring of Cardiac Implantable Electronic Devices in Italy: Results of a Survey Promoted by AIAC (Italian Association of Arrhythmology and Cardiac Pacing)
The COVID-19 pandemic has had a profound impact on the organisation of health care in Italy, with an acceleration in the development of telemedicine. To assess the impact of the COVID-19 pandemic on the spread of remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) in Italy, a survey addressed to cardiologists operating in all Italian CIED-implanting centres was launched. A total of 127 cardiologists from 116 Italian arrhythmia centres took part in the survey, 41.0% of all 283 CIED-implanting centres operating in Italy in 2019. All participating centres declared to use RM of CIEDs. COVID-19 pandemic resulted in an increase in the use of RM in 83 (71.6%) participating centres. In a temporal perspective, an increase in the median number of patients per centre followed up by RM was found from 2012 to 2017, followed by an exponential increase from 2017 to 2020. In 36 participating centres (31.0%) a telehealth visits service was activated as a replacement for in-person outpatient visits (in patients with or without CIED) during the COVID-19 pandemic. COVID-19 pandemic has caused an acceleration in the use of RM of CIEDs and in the use of telemedicine in the clinical practice of cardiology.
- 10 September 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (18) , 4086
Open AccessImpact of COVID-19 Pandemic on Remote Monitoring of Cardiac Implantable Electronic Devices in Italy: Results of a Survey Promoted by AIAC (Italian Association of Arrhythmology and Cardiac Pacing)
The COVID-19 pandemic has had a profound impact on the organisation of health care in Italy, with an acceleration in the development of telemedicine. To assess the impact of the COVID-19 pandemic on the spread of remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) in Italy, a survey addressed to cardiologists operating in all Italian CIED-implanting centres was launched. A total of 127 cardiologists from 116 Italian arrhythmia centres took part in the survey, 41.0% of all 283 CIED-implanting centres operating in Italy in 2019. All participating centres declared to use RM of CIEDs. COVID-19 pandemic resulted in an increase in the use of RM in 83 (71.6%) participating centres. In a temporal perspective, an increase in the median number of patients per centre followed up by RM was found from 2012 to 2017, followed by an exponential increase from 2017 to 2020. In 36 participating centres (31.0%) a telehealth visits service was activated as a replacement for in-person outpatient visits (in patients with or without CIED) during the COVID-19 pandemic. COVID-19 pandemic has caused an acceleration in the use of RM of CIEDs and in the use of telemedicine in the clinical practice of cardiology.
- 1 March 2020
- Published by Wolters Kluwer Health in Journal of Cardiovascular Medicine
- Vol. 21 (3) , 171-181
Intrahospital organizational model of remote monitoring data sharing, for a global management of patients with cardiac implantable electronic devices: a document of the Italian Association of Arrhythmology and Cardiac Pacing
In recent years, the increasing number of patients with a cardiac implantable electronic device (CIED) has required different approaches in terms of the device's control and surveillance. It is increasingly difficult to keep the traditional in-office protocol device's control: we must think of a different organization dedicated to the activity of remote control and monitoring (RC/RM) of devices and patients. A CIED team structured with nurses, technicians and physicians should be organized inside the hospital, with the aim of CIED patients’ managing and of creating a network between the various departments. Small hospitals may not be able to manage independently the CIEDs RC/RM and it is possible to hypothesize the creation of a collaborative network between neighbouring structures. This activity must combine the use of technology with the ability to take care of patients and to maintain adequate and meaningful relationships.
- 1 March 2020
- Published by Wolters Kluwer Health in Journal of Cardiovascular Medicine
- Vol. 21 (3) , 171-181
Intrahospital organizational model of remote monitoring data sharing, for a global management of patients with cardiac implantable electronic devices: a document of the Italian Association of Arrhythmology and Cardiac Pacing
In recent years, the increasing number of patients with a cardiac implantable electronic device (CIED) has required different approaches in terms of the device's control and surveillance. It is increasingly difficult to keep the traditional in-office protocol device's control: we must think of a different organization dedicated to the activity of remote control and monitoring (RC/RM) of devices and patients. A CIED team structured with nurses, technicians and physicians should be organized inside the hospital, with the aim of CIED patients’ managing and of creating a network between the various departments. Small hospitals may not be able to manage independently the CIEDs RC/RM and it is possible to hypothesize the creation of a collaborative network between neighbouring structures. This activity must combine the use of technology with the ability to take care of patients and to maintain adequate and meaningful relationships.
- 1 November 2019
- Published by Elsevier in Heart Rhythm
- Vol. 16 (11) , 1611-1618
Anatomy of the cavotricuspid isthmus for radiofrequency ablation in typical atrial flutter
- 1 November 2019
- Published by Elsevier in Heart Rhythm
- Vol. 16 (11) , 1611-1618
Anatomy of the cavotricuspid isthmus for radiofrequency ablation in typical atrial flutter
- 25 June 2016
- Published by Elsevier in International Journal of Cardiology
- Vol. 220, 781-786
Findings of an observational investigation of pure remote follow-up of pacemaker patients: is the in-clinic device check still needed?
- 25 June 2016
- Published by Elsevier in International Journal of Cardiology
- Vol. 220, 781-786
Findings of an observational investigation of pure remote follow-up of pacemaker patients: is the in-clinic device check still needed?
- 29 January 2016
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 18 (9) , 1391-1398
Reduction of inappropriate anti-tachycardia pacing therapies and shocks by a novel suite of detection algorithms in heart failure patients with cardiac resynchronization therapy defibrillators: a historical comparison of a prospective database
Aims Implantable cardioverter defibrillators improve survival of patients at risk for ventricular arrhythmias, but inappropriate shocks occur in up to 30% of patients and have been associated with worse quality of life and prognosis. In heart failure patients with cardiac resynchronization therapy defibrillators (CRT-Ds), we evaluated whether a new generation of detection and discrimination algorithms reduces inappropriate shocks. Methods and results We analysed 1983 Medtronic CRT-D patients (80% male, 67 ± 10 years), 1368 with standard devices (Control CRT-D) and 615 with new generation devices (New CRT-D). Expert electrophysiologists reviewed and classified the electrograms of all device-detected ventricular tachycardia/fibrillation episodes. Total follow-up was 3751 patients-years. Incidence of inappropriate shocks at 1 year was 2.8% [95% confidence interval (CI) = 2.0–3.5] in Control CRT-D and 0.9% (CI = 0.4–2.2) in New CRT-D (hazard ratio = 0.37, CI = 0.21–0.66, P < 0.001). In New CRT-D, inappropriate shocks were reduced by 77% [incidence rate ratio (IRR) = 0.23, CI = 0.16–0.35, P < 0.001] and inappropriate anti-tachycardia pacing by 81% (IRR = 0.19, CI = 0.11–0.335, P < 0.001). Annual rate per 100 patient-years for appropriate VF detections was 3.0 (CI = 2.1–4.2) in New CRT-D and 3.2 (CI = 2.1–5.0) in Control CRT-D (P = 0.68), for syncope was 0.4 (CI = 0.2–0.9) in New CRT-D and 0.7 (CI = 0.5–1.0) in Control CRT-D (P = 0.266), and for death was 1.0 (CI = 0.6–1.6) in New CRT-D and 3.5 (CI = 3.0–4.1) in Control CRT-D (P < 0.001). Conclusion Detection and discrimination algorithms used in new generation CRT-D significantly reduced inappropriate shocks when compared with standard CRT-D. This result, with no compromise on VF sensitivity or risk of syncope, has important implications for patients' quality of life and prognosis.
- 29 January 2016
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 18 (9) , 1391-1398
Reduction of inappropriate anti-tachycardia pacing therapies and shocks by a novel suite of detection algorithms in heart failure patients with cardiac resynchronization therapy defibrillators: a historical comparison of a prospective database
Aims Implantable cardioverter defibrillators improve survival of patients at risk for ventricular arrhythmias, but inappropriate shocks occur in up to 30% of patients and have been associated with worse quality of life and prognosis. In heart failure patients with cardiac resynchronization therapy defibrillators (CRT-Ds), we evaluated whether a new generation of detection and discrimination algorithms reduces inappropriate shocks. Methods and results We analysed 1983 Medtronic CRT-D patients (80% male, 67 ± 10 years), 1368 with standard devices (Control CRT-D) and 615 with new generation devices (New CRT-D). Expert electrophysiologists reviewed and classified the electrograms of all device-detected ventricular tachycardia/fibrillation episodes. Total follow-up was 3751 patients-years. Incidence of inappropriate shocks at 1 year was 2.8% [95% confidence interval (CI) = 2.0–3.5] in Control CRT-D and 0.9% (CI = 0.4–2.2) in New CRT-D (hazard ratio = 0.37, CI = 0.21–0.66, P < 0.001). In New CRT-D, inappropriate shocks were reduced by 77% [incidence rate ratio (IRR) = 0.23, CI = 0.16–0.35, P < 0.001] and inappropriate anti-tachycardia pacing by 81% (IRR = 0.19, CI = 0.11–0.335, P < 0.001). Annual rate per 100 patient-years for appropriate VF detections was 3.0 (CI = 2.1–4.2) in New CRT-D and 3.2 (CI = 2.1–5.0) in Control CRT-D (P = 0.68), for syncope was 0.4 (CI = 0.2–0.9) in New CRT-D and 0.7 (CI = 0.5–1.0) in Control CRT-D (P = 0.266), and for death was 1.0 (CI = 0.6–1.6) in New CRT-D and 3.5 (CI = 3.0–4.1) in Control CRT-D (P < 0.001). Conclusion Detection and discrimination algorithms used in new generation CRT-D significantly reduced inappropriate shocks when compared with standard CRT-D. This result, with no compromise on VF sensitivity or risk of syncope, has important implications for patients' quality of life and prognosis.
- 25 December 2015
- Published by Springer Nature
- p. 163-175
Pacemaker Malfunction: Myth or Reality?
- 19 February 2015
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 43 (1) , 45-54
Multicentre comparison Of shock efficacy using single-vs. Dual-coil lead systems and Anodal vs. cathodaL polarITY defibrillation in patients undergoing transvenous cardioverter-defibrillator implantation. The MODALITY study
An optimal active-can lead configuration during implantable cardioverter defibrillator (ICD) placement is important to obtain an adequate defibrillation safety margin. The purpose of this multicenter study was to evaluate the rate of the first shock success at defibrillation testing according to the type of lead implant (single vs. dual coil) and shock polarity (cathodal and anodal) in a large series of consecutive patients who received transvenous ICDs.
- 19 February 2015
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 43 (1) , 45-54
Multicentre comparison Of shock efficacy using single-vs. Dual-coil lead systems and Anodal vs. cathodaL polarITY defibrillation in patients undergoing transvenous cardioverter-defibrillator implantation. The MODALITY study
An optimal active-can lead configuration during implantable cardioverter defibrillator (ICD) placement is important to obtain an adequate defibrillation safety margin. The purpose of this multicenter study was to evaluate the rate of the first shock success at defibrillation testing according to the type of lead implant (single vs. dual coil) and shock polarity (cathodal and anodal) in a large series of consecutive patients who received transvenous ICDs.
- 12 August 2014
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 37 (12) , 1610-1618
Improving Atrial Fibrillation Detection in Patients with Implantable Cardiac Devices by Means of a Remote Monitoring and Management Application
Background: Atrial fibrillation (AF) is common in patients with cardiac implantable electronic devices (CIED) and has been associated with an increased stroke risk. The aim of our project was to assess the clinical value of a web‐based application, Discovery Link AFinder, in improving AF detection in CIED patients.Methods and Results: Seven Italian hospitals performed an observational study consisting of four phases. During phase 1, expert nurses and cardiologists prospectively followed‐up CIED patients via in‐hospital examinations and remote monitoring, and classified clinically relevant events, particularly AF occurrence. During phase 2, Discovery Link AFinder was exploited to identify patients who had suffered AF in the previous 12 months through the systematic scanning of device data remote transmissions. Phases 3 and 4 were repetitions of phases 1 and 2, respectively, and were implemented 6 months after the previous phases. A total of 472 consecutive patients were included in phase 1; AF occurred in 170 patients, 61 of whom were identified as new AF patients. Evidence of AF during this phase prompted prescription of oral anticoagulation (OAC) therapy in 30 patients. In phase 2, AFinder uncovered new AF, unidentified in phase 1, in 54 patients and prompted implementation of OAC therapy in 11 patients. During phase 3, 30 new AF patients were identified by means of remote monitoring, while during phase 4, a further three AF patients were identified by AFinder only.Conclusions: The AFinder web‐based software, applied on top of standard in‐hospital and remote monitoring, improved AF detection and enabled OAC treatment to be undertaken.
- 12 August 2014
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 37 (12) , 1610-1618
Improving Atrial Fibrillation Detection in Patients with Implantable Cardiac Devices by Means of a Remote Monitoring and Management Application
Background: Atrial fibrillation (AF) is common in patients with cardiac implantable electronic devices (CIED) and has been associated with an increased stroke risk. The aim of our project was to assess the clinical value of a web‐based application, Discovery Link AFinder, in improving AF detection in CIED patients.Methods and Results: Seven Italian hospitals performed an observational study consisting of four phases. During phase 1, expert nurses and cardiologists prospectively followed‐up CIED patients via in‐hospital examinations and remote monitoring, and classified clinically relevant events, particularly AF occurrence. During phase 2, Discovery Link AFinder was exploited to identify patients who had suffered AF in the previous 12 months through the systematic scanning of device data remote transmissions. Phases 3 and 4 were repetitions of phases 1 and 2, respectively, and were implemented 6 months after the previous phases. A total of 472 consecutive patients were included in phase 1; AF occurred in 170 patients, 61 of whom were identified as new AF patients. Evidence of AF during this phase prompted prescription of oral anticoagulation (OAC) therapy in 30 patients. In phase 2, AFinder uncovered new AF, unidentified in phase 1, in 54 patients and prompted implementation of OAC therapy in 11 patients. During phase 3, 30 new AF patients were identified by means of remote monitoring, while during phase 4, a further three AF patients were identified by AFinder only.Conclusions: The AFinder web‐based software, applied on top of standard in‐hospital and remote monitoring, improved AF detection and enabled OAC treatment to be undertaken.
- 1 December 2011
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 4 (6) , 844-850
Efficacy of Low Interatrial Septum and Right Atrial Appendage Pacing for Prevention of Permanent Atrial Fibrillation in Patients With Sinus Node Disease
Background—: The role of pacing sites and atrial electrophysiology on the progression of atrial fibrillation (AF) to the permanent form in patients with sinus node dysfunction (SND) has never been investigated. The aim of the study was to investigate the relationship between atrial electrophysiology and the efficacy of atrial pacing at the low interatrial septum (IAS) or at the right atrial appendage (RAA) to prevent persistent/permanent AF in patients with SND. Methods and Results—: The Electrophysiology-Guided Pacing Site Selection (EPASS) Study was a prospective, controlled, randomized study. Atrial refractoriness, basal and incremental conduction times from the RAA to the coronary sinus ostium were measured before implantation, and the difference (ΔCTos) was calculated. Patients with ΔCTos ≥50 ms (study group) and those with ΔCTos P =0.047). Conclusions—: In patients with SND and intra-atrial conduction delay, low IAS pacing was superior to RAA pacing in preventing progression to persistent or permanent AF. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT00239226.
- 1 December 2011
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 4 (6) , 844-850
Efficacy of Low Interatrial Septum and Right Atrial Appendage Pacing for Prevention of Permanent Atrial Fibrillation in Patients With Sinus Node Disease
Background—: The role of pacing sites and atrial electrophysiology on the progression of atrial fibrillation (AF) to the permanent form in patients with sinus node dysfunction (SND) has never been investigated. The aim of the study was to investigate the relationship between atrial electrophysiology and the efficacy of atrial pacing at the low interatrial septum (IAS) or at the right atrial appendage (RAA) to prevent persistent/permanent AF in patients with SND. Methods and Results—: The Electrophysiology-Guided Pacing Site Selection (EPASS) Study was a prospective, controlled, randomized study. Atrial refractoriness, basal and incremental conduction times from the RAA to the coronary sinus ostium were measured before implantation, and the difference (ΔCTos) was calculated. Patients with ΔCTos ≥50 ms (study group) and those with ΔCTos P =0.047). Conclusions—: In patients with SND and intra-atrial conduction delay, low IAS pacing was superior to RAA pacing in preventing progression to persistent or permanent AF. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT00239226.
- 1 September 2007
- Published by Wolters Kluwer Health in Journal of Cardiovascular Medicine
- Vol. 8 (9) , 706-712
Prevalence of conduction delay of the right atrium in patients with SSS: implications for pacing site selection
To evaluate the prevalence of severe right atrial conduction delay in patients with sinus node dysfunction (SND) and atrial fibrillation (AF) and the effects of pacing in the right atrial appendage (RAA) and in the inter-atrial septum (IAS). Forty-two patients (15 male, 72 ± 7 years) underwent electrophysiologic study to measure the difference between the conduction time from RAA to coronary sinus ostium during stimulation at 600 ms and after extrastimulus (ΔCTos). Patients were classified as group A if ΔCTos > 60 ms and group B if < 60 ms. Each Group was randomized to RAA/IAS pacing and algorithms ON/OFF. Fifteen patients (36%, group A) had ΔCTos = 76 ± 11 ms and 27 patients (64%, group B) had ΔCTos = 36 ± 20 ms. Twenty-two patients were paced at the RAA and 20 at the IAS. During the study, no AF recurrences were reported in 11 of 42 (26%) patients, independently of RAA or IAS pacing. Patients from group A and RAA pacing had 0.79 ± 0.81 episodes of AF/day during DDD, which increased to 1.52 ± 1.41 episodes of AF/day during DDDR + Alg (P = 0.046). Those with IAS pacing had 0.5 ± 0.24 episodes of AF/day during DDD, which decreased to 0.06 ± 0.08 episodes of AF/day during DDDR + Alg (P = 0.06). In group B, no differences were reported between pacing sites and pacing modes. Severe right atrial conduction delay is present in one-third of patients with SND and AF: continuous pacing at the IAS is superior to RAA for AF recurrences. In patients without severe conduction delay, no differences between pacing site or mode were observed.
- 1 September 2007
- Published by Wolters Kluwer Health in Journal of Cardiovascular Medicine
- Vol. 8 (9) , 706-712
Prevalence of conduction delay of the right atrium in patients with SSS: implications for pacing site selection
To evaluate the prevalence of severe right atrial conduction delay in patients with sinus node dysfunction (SND) and atrial fibrillation (AF) and the effects of pacing in the right atrial appendage (RAA) and in the inter-atrial septum (IAS). Forty-two patients (15 male, 72 ± 7 years) underwent electrophysiologic study to measure the difference between the conduction time from RAA to coronary sinus ostium during stimulation at 600 ms and after extrastimulus (ΔCTos). Patients were classified as group A if ΔCTos > 60 ms and group B if < 60 ms. Each Group was randomized to RAA/IAS pacing and algorithms ON/OFF. Fifteen patients (36%, group A) had ΔCTos = 76 ± 11 ms and 27 patients (64%, group B) had ΔCTos = 36 ± 20 ms. Twenty-two patients were paced at the RAA and 20 at the IAS. During the study, no AF recurrences were reported in 11 of 42 (26%) patients, independently of RAA or IAS pacing. Patients from group A and RAA pacing had 0.79 ± 0.81 episodes of AF/day during DDD, which increased to 1.52 ± 1.41 episodes of AF/day during DDDR + Alg (P = 0.046). Those with IAS pacing had 0.5 ± 0.24 episodes of AF/day during DDD, which decreased to 0.06 ± 0.08 episodes of AF/day during DDDR + Alg (P = 0.06). In group B, no differences were reported between pacing sites and pacing modes. Severe right atrial conduction delay is present in one-third of patients with SND and AF: continuous pacing at the IAS is superior to RAA for AF recurrences. In patients without severe conduction delay, no differences between pacing site or mode were observed.