    Combined ADC and T 2 Mapping in the Prostate Using a 3D Reduced FOV Sequence

    by Yannik Ott, Sarah McElroy, Raphael Tomi‐Tricot, Carolyn Horst, Patricia A. Gutierrez, Rahul Khamar, Omar Darwish, Vicky Goh, Radhouene Neji

    Purpose: To develop a 3D reduced FOV sequence for combined ADC and T 2 mapping in the prostate in a single scan. Methods: A 3D ADC and T 2 mapping reduced FOV acquisition is enabled using T 2 and diffusion preparation modules with slab‐selective tip‐down pulses and magnitude stabilizer gradients. Imaging shots are followed by 2D phase navigators for phase correction of diffusion‐prepared shots and dummy RF pulses for T 2 ‐prepared shots, as well as a constant delay to maintain the steady state of the longitudinal magnetization. Mono‐exponential fitting is used for ADC and T 2 mapping. T 2 mapping accuracy was assessed in a phantom against a single‐echo spin‐echo reference. In vivo, the sequence was compared in the prostate of 11 healthy volunteers against a multi‐echo spin‐echo acquisition, as well as standard and reduced FOV (rFOV) single‐shot EPI (ssEPI). Results: In the phantom experiments, T 2 values were not significantly different from the reference single‐echo spin‐echo measurements. ADC values in vivo were not significantly different from those obtained using ssEPI. T 2 values in vivo showed a mean bias of −21.7 ms compared to those obtained using multi‐echo spin‐echo with the first echo discarded in the fitting. The proposed sequence achieved similar overall image quality scores to those of ssEPI and rFOV ssEPI, improved perceived distortion scores, but lower perceived SNR scores. Conclusion: The proposed approach enables 3D reduced FOV, single‐scan ADC, and T 2 mapping with mono‐exponential fitting in the prostate.

  • Clinical applications of the kT-points method to homogenise spin excitation in 3T MRI

    by Raphaël Tomi-Tricot

    Applications cliniques de la méthode des points kT pour homogénéiser l'excitation des spins en IRM à 3 teslas: L'imagerie par résonance magnétique (IRM) à haut champ offre un bénéfice certain en rapport signal-sur-bruit. De ce fait, les imageurs à 3T sont souvent utilisés en pratique clinique.Cependant, à haut champ, les images d'IRM sont entachées de pertes de signal et de contraste liées à la baisse de la longueur d’onde radiofréquence (RF) en deçà des dimensions de l'objet irradié. A 3T, où la longueur d'onde est de 30 cm environ dans les tissus humains, de tels artéfacts sont fréquents en imagerie abdominale, des seins ou encore des cuisses, ce qui peut expliquer la difficulté que rencontre l'IRM à haut champ à s'imposer comme référence dans les hôpitaux. Les imageurs 3T les plus récents disposent en général d'un système de transmission parallèle à deux canaux RF. Chaque canal peut en principe émettre des formes d'impulsion RF indépendantes. En pratique, sur la plupart des systèmes IRM cliniques, la méthode dite de shim RF statique est utilisée. Les différents canaux transmettent la même forme d’onde,en ajustant amplitude et phase de sorte à entraîner des motifs d’interférences pour contrer les inhomogénéités, mesurées au préalable sur le patient: cartes de champ RF et éventuellement de champ statique. Cette méthode fonctionne d’autant mieux qu’un grand nombre de canaux est disponible, mais montre ses limites lorsqu’il s’agit d’homogénéiser l’excitation sur un grand champ de vue. La méthode des points kT, développée à NeuroSpin pour l’IRM cérébrale à ultra-haut champ (7T) utilise une alternance d’impulsions RF rectangulaires et de gradients de champ statique pour moduler à dessein l’aimantation des spins et ainsi homogénéiser l’excitation malgré un champ RF inhomogène. Les impulsions ainsi créées sont d’autant plus efficaces qu’elles peuvent exploiter la transmission parallèle (huit canaux à 7T). Dans cette thèse, les points kT sont employés à 3T avec pour objectif d’en démontrer l’intérêt et l’applicabilité en routine clinique. Dans un premier temps, nous décrivons des modifications apportées à l’algorithme de conception de points kT et à la cartographie de champ statique permettant d’adapter la technique à l’imagerie du corps – foie, seins – où la présence des poumons et de la graisse entraîne des contraintes supplémentaires par rapport au cerveau.Dans un second temps, plusieurs études cliniques sont exposées. La première concerne l’IRM du sein en pondération T₂ sur un imageur à canal d’émission unique. Elle met en évidence que le mode d’émission par défaut fonctionne correctement et n’est que peu amélioré par les points kT. Une deuxième étude se penche sur l’imagerie dynamique du foie avec injection de produit de contraste, avec deux canaux. Des analyses quantitatives et qualitatives sont menées sur un grand nombre de patients pour comparer le shim RF statique avec les points kT. Ces derniers améliorent très nettement les images obtenues chez certains patients« difficiles », permettant ainsi d’offrir une qualité d’examen et de diagnostic plus homogène sur l’ensemble de la population. Enfin,une nouvelle technique est présentée, intitulée SmartPulse, qui s’appuie sur le concept d’impulsions universelles, développé à NeuroSpin pour l’imagerie du cerveau, et dont le principe est de concevoir des impulsions de type points kT qui, pour une application donnée, soient efficaces sur toute la population et permettent de se passer de calibration. En divisant la population en catégories pour lesquelles des impulsions différentes sont conçues,et en utilisant un algorithme de classification par apprentissage automatique, SmartPulse étend la portée des impulsions universelles au corps, et en particulier à l’abdomen, où la variabilité morphologique est importante. Par ces travaux de thèse, nous espérons donner un nouveau souffle à la gestion des inhomogénéités RF en routine clinique à 3T, et apporter des éléments permettant à terme de démocratiser l’imagerie des gros organes à ultra-haut champ.

  • Open Access

    Ultra-High Field 7T MRI in a Drug-Resistant Pediatric Epilepsy Cohort

    by Katy Vecchiato, Chiara Casella, Ayse Sila Dokumaci, Ata Siddiqui, Alexia Egloff, Olivia Carney, Jon O. Cleary, Jozef Jarosz, Pierluigi Di Ciò, Michela Cleri, et al.

    Epileptogenic lesions in focal epilepsy can be subtle or remain undetected on conventional MRI. Ultra-high field (7T) MRI offers higher spatial resolution, contrast, and signal-to-noise ratio compared with conventional field strengths and has shown promise in adult presurgical evaluation. However, its utility in pediatric focal epilepsy, where malformations of cortical development are common, remains unclear. In this study, we directly compared 7T and 3T MRI in children with drug-resistant focal epilepsy, evaluating (1) scan tolerability, (2) image quality, and (3) lesion detection yield. In this prospective cohort study, patients were recruited from outpatient clinics at 3 large epilepsy centers in London. Eligible participants were aged 8-17 years and had no contraindications to MRI. Scanning was conducted in 2 separate sessions at 3T and 7T. Safety and tolerability were assessed using age-specific questionnaires and analyzed using the Mann-Whitney test for differences between age groups and the McNemar χ2 test for within-participant cross-field comparisons. Image quality was evaluated by a pediatric neuroradiologist and estimated quantitatively by comparing cortical thickness between field strengths. Lesion detection yield of 7T MRI was assessed by joint review with a multidisciplinary team. A total of 63 children were assessed: 41 patients (mean age 12.6 ± 2.4 years, 22 were male) and 22 healthy controls (8-17 years, mean age 11.7 ± 2.7 years, 15 were male). Both field strengths were well tolerated, and side effects were transient. These included higher dizziness-related discomfort at 7T (p = 0.02, Cohen h = 0.89), with side effects more frequently noted in younger children (scanner noise: p = 0.02, Cohen r = -0.36; metallic taste: p = 0.02, Cohen r = -0.37). Cortical thickness was significantly thinner at 7T for both right (t = 5.65, p < 0.001, Cohen d = -0.72) and left (t = 5.01, p < 0.001, Cohen d = -0.64) hemispheres, with thinner boundaries in temporo-parietal/sensory regions. Although 7T images had increased reported inhomogeneity and artifacts, new lesions were detected in 6 of 26 patients (23%), influencing surgical management in 4 of 26 (15%) (odds ratio 1.86). 7T MRI in children with epilepsy is well tolerated and associated with a 23% improvement in lesion detection, directly affecting clinical management and surgical outcomes. Although limited by a preselected cohort with extensive diagnostic workups, our findings underscore the transformative potential of 7T MRI in presurgical planning for pediatric epilepsy.


  • Open Access

    Fetal body organ T2* relaxometry at low field strength (FOREST)

    by Kelly Payette, Alena U. Uus, Jordina Aviles Verdera, Megan Hall, Alexia Egloff, Maria Deprez, Raphaël Tomi-Tricot, Joseph V. Hajnal, Mary A. Rutherford, Lisa Story, et al.


  • Open Access

    Sequence‐agnostic motion‐correction leveraging efficiently calibrated Pilot Tone signals

    by Yannick Brackenier, Lucilio Cordero‐Grande, Sarah McElroy, Raphael Tomi‐Tricot, Hugo Barbaroux, Philippa Bridgen, Shaihan J. Malik, Joseph V. Hajnal

    Purpose: This study leverages externally generated Pilot Tone (PT) signals to perform motion‐corrected brain MRI for sequences with arbitrary k‐space sampling and image contrast.Theory and Methods: PT signals are promising external motion sensors due to their cost‐effectiveness, easy workflow, and consistent performance across contrasts and sampling patterns. However, they lack robust calibration pipelines. This work calibrates PT signal to rigid motion parameters acquired during short blocks (˜4 s) of motion calibration (MC) acquisitions, which are short enough to unobstructively fit between acquisitions. MC acquisitions leverage self‐navigated trajectories that enable state‐of‐the‐art motion estimation methods for efficient calibration. To capture the range of patient motion occurring throughout the examination, distributed motion calibration (DMC) uses data acquired from MC scans distributed across the entire examination. After calibration, PT is used to retrospectively motion‐correct sequences with arbitrary k‐space sampling and image contrast. Additionally, a data‐driven calibration refinement is proposed to tailor calibration models to individual acquisitions. In vivo experiments involving 12 healthy volunteers tested the DMC protocol's ability to robustly correct subject motion.Results: The proposed calibration pipeline produces pose parameters consistent with reference values, even when distributing only six of these approximately 4‐s MC blocks, resulting in a total acquisition time of 22 s. In vivo motion experiments reveal significant () improved motion correction with increased signal to residual ratio for both MPRAGE and SPACE sequences with standard k‐space acquisition, especially when motion is large. Additionally, results highlight the benefits of using a distributed calibration approach.Conclusions: This study presents a framework for performing motion‐corrected brain MRI in sequences with arbitrary k‐space encoding and contrast, using externally generated PT signals. The DMC protocol is introduced, promoting observation of patient motion occurring throughout the examination and providing a calibration pipeline suitable for clinical deployment. The method's application is demonstrated in standard volumetric MPRAGE and SPACE sequences.


  • Reliability and Feasibility of Low-Field-Strength Fetal MRI at 0.55 T during Pregnancy

    by Jordina Aviles Verdera, Lisa Story, Megan Hall, Tom Finck, Alexia Egloff, Paul T. Seed, Shaihan J. Malik, Mary A. Rutherford, Joseph V. Hajnal, Raphaël Tomi-Tricot, et al.

    Background The benefits of using low-field-strength fetal MRI to evaluate antenatal development include reduced image artifacts, increased comfort, larger bore size, and potentially reduced costs, but studies about fetal low-field-strength MRI are lacking. Purpose To evaluate the reliability and feasibility of low-field-strength fetal MRI to assess anatomic and functional measures in pregnant participants using a commercially available 0.55-T MRI scanner and a comprehensive 20-minute protocol. Materials and Methods This prospective study was performed at a large teaching hospital (St Thomas' Hospital; London, England) from May to November 2022 in healthy pregnant participants and participants with pregnancy-related abnormalities using a commercially available 0.55-T MRI scanner. A 20-minute protocol was acquired including anatomic T2-weighted fast-spin-echo, quantitative T2*, and diffusion sequences. Key measures like biparietal diameter, transcerebellar diameter, lung volume, and cervical length were evaluated by two radiologists and an MRI-experienced obstetrician. Functional organ-specific mean values were given. Comparison was performed with existing published values and higher-field MRI using linear regression, interobserver correlation, and Bland-Altman plots. Results A total of 79 fetal MRI examinations were performed (mean gestational age, 29.4 weeks ± 5.5 [SD] [age range, 17.6-39.3 weeks]; maternal age, 34.4 years ± 5.3 [age range, 18.4-45.5 years]) in 47 healthy pregnant participants (control participants) and in 32 participants with pregnancy-related abnormalities. The key anatomic two-dimensional measures for the 47 healthy participants agreed with large cross-sectional 1.5-T and 3-T control studies. The interobserver correlations for the biparietal diameter in the first 40 consecutive scans were 0.96 (95% CI: 0.7, 0.99; P = .002) for abnormalities and 0.93 (95% CI: 0.86, 0.97; P < .001) for control participants. Functional features, including placental and brain T2* and placental apparent diffusion coefficient values, strongly correlated with gestational age (mean placental T2* in the control participants: 5.2 msec of decay per week; R2 = 0.66; mean T2* at 30 weeks, 176.6 msec; P < .001). Conclusion The 20-minute low-field-strength fetal MRI examination protocol was capable of producing reliable structural and functional measures of the fetus and placenta in pregnancy. Clinical trial registration no. REC 21/LO/0742 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Gowland in this issue.


  • Open Access

    Data‐driven motion‐corrected brain MRI incorporating pose‐dependent B0 fields

    by Yannick Brackenier, Lucilio Cordero‐Grande, Raphael Tomi‐Tricot, Thomas Wilkinson, Philippa Bridgen, Anthony Price, Shaihan J. Malik, Enrico De Vita, Joseph V. Hajnal

    Purpose: To develop a fully data‐driven retrospective intrascan motion‐correction framework for volumetric brain MRI at ultrahigh field (7 Tesla) that includes modeling of pose‐dependent changes in polarizing magnetic (B0) fields.Theory and Methods: Tissue susceptibility induces spatially varying B0 distributions in the head, which change with pose. A physics‐inspired B0 model has been deployed to model the B0 variations in the head and was validated in vivo. This model is integrated into a forward parallel imaging model for imaging in the presence of motion. Our proposal minimizes the number of added parameters, enabling the developed framework to estimate dynamic B0 variations from appropriately acquired data without requiring navigators. The effect on data‐driven motion correction is validated in simulations and in vivo.Results: The applicability of the physics‐inspired B0 model was confirmed in vivo. Simulations show the need to include the pose‐dependent B0 fields in the reconstruction to improve motion‐correction performance and the feasibility of estimating B0 evolution from the acquired data. The proposed motion and B0 correction showed improved image quality for strongly corrupted data at 7 Tesla in simulations and in vivo.Conclusion: We have developed a motion‐correction framework that accounts for and estimates pose‐dependent B0 fields. The method improves current state‐of‐the‐art data‐driven motion‐correction techniques when B0 dependencies cannot be neglected. The use of a compact physics‐inspired B0 model together with leveraging the parallel imaging encoding redundancy and previously proposed optimized sampling patterns enables a purely data‐driven approach.


  • Open Access

    Parallel transmit pulse design for saturation homogeneity (PUSH) for magnetization transfer imaging at 7T

    by David Leitão, Raphael Tomi‐Tricot, Pip Bridgen, Tom Wilkinson, Patrick Liebig, Rene Gumbrecht, Dieter Ritter, Sharon L. Giles, Ana Baburamani, Jan Sedlacik, et al.

    Purpose: This work proposes a novel RF pulse design for parallel transmit (pTx) systems to obtain uniform saturation of semisolid magnetization for magnetization transfer (MT) contrast in the presence of transmit field inhomogeneities. The semisolid magnetization is usually modeled as being purely longitudinal, with the applied field saturating but not rotating its magnetization; thus, standard pTx pulse design methods do not apply.Theory and Methods: Pulse design for saturation homogeneity (PUSH) optimizes pTx RF pulses by considering uniformity of root‐mean squared , , which relates to the rate of semisolid saturation. Here we considered designs consisting of a small number of spatially non‐selective sub‐pulses optimized over either a single 2D plane or 3D. Simulations and in vivo experiments on a 7T Terra system with an 8‐TX Nova head coil in five subjects were carried out to study the homogenization of and of the MT contrast by acquiring MT ratio maps.Results: Simulations and in vivo experiments showed up to six and two times more uniform compared to circular polarized (CP) mode for 2D and 3D optimizations, respectively. This translated into 4 and 1.25 times more uniform MT contrast, consistently for all subjects, where two sub‐pulses were enough for the implementation and coil used.Conclusion: The proposed PUSH method obtains more uniform and higher MT contrast than CP mode within the same specific absorption rate (SAR) budget.


  • Open Access

    Interventional cardiac MRI using an add‐on parallel transmit MR system: In vivo experience in sheep

    by Felipe Godinez, Raphael Tomi‐Tricot, Marylène Delcey, Steven E. Williams, Ronald Mooiweer, Bruno Quesson, Reza Razavi, Joseph V. Hajnal, Shaihan J. Malik

    Purpose: We present in vivo testing of a parallel transmit system intended for interventional MR‐guided cardiac procedures.Methods: The parallel transmit system was connected in‐line with a conventional 1.5 Tesla MRI system to transmit and receive on an 8‐coil array. The system used a current sensor for real‐time feedback to achieve real‐time current control by determining coupling and null modes. Experiments were conducted on 4 Charmoise sheep weighing 33.9‐45.0 kg with nitinol guidewires placed under X‐ray fluoroscopy in the atrium or ventricle of the heart via the femoral vein. Heating tests were done in vivo and post‐mortem with a high RF power imaging sequence using the coupling mode. Anatomical imaging was done using a combination of null modes optimized to produce a useable B1 field in the heart.Results: Anatomical imaging produced cine images of the heart comparable in quality to imaging with the quad mode (all channels with the same amplitude and phase). Maximum observed temperature increases occurred when insulation was stripped from the wire tip. These were 4.1℃ and 0.4℃ for the coupling mode and null modes, respectively for the in vivo case; increasing to 6.0℃ and 1.3℃, respectively for the ex vivo case, because cooling from blood flow is removed. Heating < 0.1℃ was observed when insulation was not stripped from guidewire tips. In all tests, the parallel transmit system managed to reduce the temperature at the guidewire tip.Conclusion: We have demonstrated the first in vivo usage of an auxiliary parallel transmit system employing active feedback‐based current control for interventional MRI with a conventional MRI scanner.