Hao Cao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Hao Cao has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Pu Li
Group of Process Optimization, Institute for Automation and Systems Engineering, Technical University of Ilmenau, P.O. Box 100565, 98684 Ilmenau, Germany
3 shared publications - Avi Ostfeld
Faculty of Civil and Environmental Engineering, Technion—Israel Institute of Technology, Haifa 32000, Israel
2 shared publications - Elad Salomons
Optiwater
2 shared publications - Kristina Korder
Process Optimization Group Technische Universität Ilmenau Ilmenau Germany
1 shared publication - Siegbert Hopfgarten
Process Optimization Group, Institute of Automation and Systems Engineering, Technical University Ilmenau, 98693 Ilmenau, Germany
1 shared publication
Latest Publications
- Open Access
- 13 September 2024
- Published by MDPI AG in Engineering Proceedings
- Vol. 69 (1) , 134
A Flushing Duration Model for a Campaign against Contamination in Water Distribution Systems
Contamination poses a significant risk to public health by degrading water quality in water distribution systems (WDSs). As one of the key tasks of a response strategy to contamination incidents in a WDS, pipe system flushing has been widely implemented in practice. However, due to the complexity of the network structure and chemical reaction within the pipe system, determining the flushing duration is still one of the significant challenges for a given network. To address this problem, a model for determining the flushing duration is developed. This model is based on calculating the traveling trajectory of the contaminant inside the network. This is carried out by discretizing the one-dimension advection equation and calculating the variation of the contaminant concentration from one segment to another over time. As a preliminary study, we focus on simplified scenarios where contaminants exhibit no chemical reaction within the WDS. The proposed model is applied and analyzed through a simulation study and a laboratory testbed. The results demonstrate the efficacy of the model for determining flushing duration, which can offer valuable insights for real-world applications and serve as a crucial reference for water utility companies.
- 13 September 2024
- Published by MDPI AG in Engineering Proceedings
- Vol. 69 (1) , 134
Open AccessA Flushing Duration Model for a Campaign against Contamination in Water Distribution Systems
Contamination poses a significant risk to public health by degrading water quality in water distribution systems (WDSs). As one of the key tasks of a response strategy to contamination incidents in a WDS, pipe system flushing has been widely implemented in practice. However, due to the complexity of the network structure and chemical reaction within the pipe system, determining the flushing duration is still one of the significant challenges for a given network. To address this problem, a model for determining the flushing duration is developed. This model is based on calculating the traveling trajectory of the contaminant inside the network. This is carried out by discretizing the one-dimension advection equation and calculating the variation of the contaminant concentration from one segment to another over time. As a preliminary study, we focus on simplified scenarios where contaminants exhibit no chemical reaction within the WDS. The proposed model is applied and analyzed through a simulation study and a laboratory testbed. The results demonstrate the efficacy of the model for determining flushing duration, which can offer valuable insights for real-world applications and serve as a crucial reference for water utility companies.
- Open Access
- 8 April 2024
- Published by Springer Nature in Water Resources Management
- Vol. 38 (10) , 3561-3579
Simultaneous Minimization of Water Age and Pressure in Water Distribution Systems by Pressure Reducing Valves
Pressure reducing valves (PRVs) are essentially used to reduce operational pressures in water distribution systems (WDSs) to minimize water leakage. However, water age in a WDS is an important variable describing the water quality and should be kept as low as possible. Therefore, the aim of this study is to investigate the possibility and potential of simultaneously minimizing both pressure and water age by using PRVs. To determine the optimal location and setting of PRVs, a mixed-integer nonlinear programming (MINLP) problem is formulated with minimization of the sum of the weighted total water age and pressure as the objective function, where the weighting factor can be defined by the user’s preference. The equality constraints consist of the hydraulic equations and water age functions to describe pressure and water age in the distribution network, while the inequality constraints ensure them in the defined operating ranges, respectively. Applying the proposed approach to two case studies, the results show that both water age and pressure can indeed be significantly reduced by the optimized position and setting of the PRVs.
- 8 April 2024
- Published by Springer Nature in Water Resources Management
- Vol. 38 (10) , 3561-3579
Open AccessSimultaneous Minimization of Water Age and Pressure in Water Distribution Systems by Pressure Reducing Valves
Pressure reducing valves (PRVs) are essentially used to reduce operational pressures in water distribution systems (WDSs) to minimize water leakage. However, water age in a WDS is an important variable describing the water quality and should be kept as low as possible. Therefore, the aim of this study is to investigate the possibility and potential of simultaneously minimizing both pressure and water age by using PRVs. To determine the optimal location and setting of PRVs, a mixed-integer nonlinear programming (MINLP) problem is formulated with minimization of the sum of the weighted total water age and pressure as the objective function, where the weighting factor can be defined by the user’s preference. The equality constraints consist of the hydraulic equations and water age functions to describe pressure and water age in the distribution network, while the inequality constraints ensure them in the defined operating ranges, respectively. Applying the proposed approach to two case studies, the results show that both water age and pressure can indeed be significantly reduced by the optimized position and setting of the PRVs.
- Open Access
Simultaneous Sensor Placement and Pressure Reducing Valve Localization for Pressure Control of Water Distribution Systems
Many studies on pressure sensor (PS) placement and pressure reducing valve (PRV) localization in water distribution systems (WDSs) have been made with the objective of improving water leakage detection and pressure reduction, respectively. However, due to varying operation conditions, it is expected to realize pressure control using a number of PSs and PRVs to keep minimum operating pressure in real-time. This study aims to investigate the PS placement and PRV localization for the purpose of pressure control system design for WDSs. For such a control system, a PS should be positioned to represent the pressure patterns of a region of the WDS. Correspondingly, a PRV should be located to achieve a maximum pressure reduction between two neighboring regions. According to these considerations, an approach based on the k-means++ method for simultaneously determining the numbers and positions of both PSs and PRVs is proposed. Results from three case studies are presented to demonstrate the effectiveness of the suggested approach. It is shown that the sensors positioned have a high accuracy of pressure representation and the valves localized lead to a significant pressure reduction.
Open AccessSimultaneous Sensor Placement and Pressure Reducing Valve Localization for Pressure Control of Water Distribution Systems
Many studies on pressure sensor (PS) placement and pressure reducing valve (PRV) localization in water distribution systems (WDSs) have been made with the objective of improving water leakage detection and pressure reduction, respectively. However, due to varying operation conditions, it is expected to realize pressure control using a number of PSs and PRVs to keep minimum operating pressure in real-time. This study aims to investigate the PS placement and PRV localization for the purpose of pressure control system design for WDSs. For such a control system, a PS should be positioned to represent the pressure patterns of a region of the WDS. Correspondingly, a PRV should be located to achieve a maximum pressure reduction between two neighboring regions. According to these considerations, an approach based on the k-means++ method for simultaneously determining the numbers and positions of both PSs and PRVs is proposed. Results from three case studies are presented to demonstrate the effectiveness of the suggested approach. It is shown that the sensors positioned have a high accuracy of pressure representation and the valves localized lead to a significant pressure reduction.