ESEdward A. Stanley

Edward A. Stanley

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Edward A. Stanley has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Vlad Illie

    Department of Plastic and Reconstructive Surgery St Vincent's Hospital Sydney New South Wales Australia

    2 shared publications
  • Andrea C. Issler-Fisher

    Burns Unit, Concord Repatriation General Hospital, Sydney, Australia; ANZAC Research Institute, Concord Repatriation General Hospital, Sydney, Australia; Concord Clinical School, University of Sydney, Sydney, Australia

    1 shared publication
  • Andrew Cavallo

    Department of Plastic and Reconstructive Surgery, Austin Health, Melbourne, Victoria, Australia

    1 shared publication
  • Bridget Hill

    Department of Occupational Therapy, Austin Health, Heidelberg, VIC, Australia Epworth

    1 shared publication
  • Dean P. McKenzie

    Research Development and Governance Unit, Epworth HealthCare, Richmond, VIC, Australia

    1 shared publication
  • Derek Neoh

    Department of Plastic and Reconstructive Surgery Austin Health Heidelberg Victoria Australia

    1 shared publication

Latest Publications

  • Arterializing the Venous System in a SCIP Flap—Insights Into Tissue Perfusion Biomechanics: A Case Report

    by Edward A. Stanley, Vlad Illie

    This case report presents a novel observation on tissue perfusion biomechanics achieved through arterializing the deep venous system in a superficial circumflex iliac artery perforator (SCIP) flap. An 89‐year‐old male with a cutaneous squamous cell carcinoma overlying the mandible underwent SCIP flap reconstruction. The flap was 5 mm thick and measured 8 cm × 7 cm. Due to pedicle damage, the venae comitantes served as the inflow system, anastomosed to a facial artery branch, while the superficial circumflex iliac vein served as the outflow system. The flap initially showed venous congestion but resolved without intervention, healing with an acceptable color match and contour over a six‐month follow‐up. This novel technique suggests that venous systems can be repurposed to support tissue perfusion effectively, offering new insights into tissue perfusion biomechanics. The broader implications of this approach include expanding our understanding of tissue perfusion mechanisms, which could lead to broader applications in reconstructive surgery. Ultimately, this method may enable the use of donor sites that do not rely on intrinsic arterial systems, potentially increasing the versatility of flap reconstruction techniques.

  • Full Thickness, Near‐Total to Total Lower Lip Reconstruction Using Superficial Circumflex Iliac Artery Perforator Free Flap: A Case Report

    by Edward A. Stanley, Vlad Illie

    Near‐total to total lower lip defects present significant challenges for reconstructive surgeons, requiring restoration of oral competency, maximization of oral aperture, and cosmetic appearance. This report explores a novel reconstructive option addressing all three needs. Traditionally, local flap options restore cosmesis and oral competency by recruiting local tissue of similar thickness, pliability, and appearance, but often result in microstomia. Conversely, free flaps prevent microstomia but can lead to bulky and cosmetically unacceptable reconstructions. We present the first case of using a super‐thin superficial circumflex iliac artery perforator (SCIP) free flap for near‐total, full‐thickness lower lip reconstruction. The patient was a 66‐year‐old female with recurrent squamous cell carcinoma of the lower lip, requiring wide local excision and resulting in an 80% full‐thickness defect with unilateral oral commissure loss. An 8 cm × 5 cm × 5 mm SCIP flap was raised with a 4.5‐cm pedicle length and anastomosed to the facial artery and vein. Clear fluids were commenced 7 days postoperatively, wounds healed 2 weeks postoperatively, and a normal diet was resumed at this time. The SCIP flap offers an excellent additional option for managing full‐thickness near‐total to total lower lip defects. Its thin, pliable nature and minimal donor site morbidity help restore oral competency, maximize oral aperture, and achieve a pleasing cosmetic result.

  • Understanding Neural Factors in Burn-related Pruritus and Neuropathic Pain

    by Dulan A Gunawardena, Edward Stanley, Andrea C Issler-Fisher

    Post-burn pruritus and neuropathic pain significantly affect the quality of life of affected individuals in several domains including psychosocial well-being, sleep and general impairment in activities of daily living. Whilst neural mediators involved in itch in the non-burns setting have been well investigated, there remains a lacuna of literature examining the pathophysiological and histological changes unique to burn-related pruritus and neuropathic pain. The aim of our study was to conduct a scoping review into the neural factors that contribute to burn-related pruritus and neuropathic pain. A scoping review was conducted to provide an overview of the available evidence. The PubMed, EMBASE and Medline databases were searched for publications. Data regarding neural mediators implicated, population demographics, total body surface area (TBSA) affected and sex was extracted. In total, 11 studies were included in this review with a total of 881 patients. The most frequently investigated neurotransmitter was the Substance P (SP) neuropeptide which appeared in 36% of studies (n = 4), followed by calcitonin gene-related peptide (CGRP) in 27% of studies (n = 3). Post-burn pruritus and neuropathic pain are symptomatic experiences that are predicated upon a heterogeneous group of underlying mechanisms. What is clear from the literature, however, is that itch and pain may occur secondary to the influence of both neuropeptides, such as SP, and other neural mediators including Transient receptor protein channels. Of the articles included for review, they were characterized by small sample sizes and large differences in statistical methodology and reporting.


  • Predicting strength outcomes for upper limb nerve transfer surgery in tetraplegia

    by Edward A. Stanley, Bridget Hill, Dean P. McKenzie, Pierre Chapuis, Mary P. Galea, Natasha van Zyl

    We report a retrospective study of 112 nerve transfers in 39 participants to investigate predictors of strength outcomes after nerve transfer surgery for upper limb reanimation in tetraplegia. We measured clinical and pre- and intraoperative neurophysiological assessment variables and compared them with strength outcomes 2 years after nerve transfer surgery. We found statistically significant improvement in Medical Research Council strength grades after nerve transfer surgery with lower cervical spine injuries (between one and two grades), lower donor nerve stimulation thresholds (half of a grade), greater motor evoked potential activity in recipient nerves (half of a grade) and greater muscle responses to intraoperative stimulation of donor (half of a grade) and recipient nerves (half of a grade). Level of evidence: III


  • Open Access

    Experience with NovoSorb® Biodegradable Temporising Matrix in reconstruction of complex wounds

    by Henry Li, Pelicia Lim, Edward Stanley, Geoffrey Lee, Sandra Lin, Derek Neoh, Julian Liew, Sally Kiu‐Huen Ng

    Background: The NovoSorb® Biodegradable Temporising Matrix (BTM) is a synthetic polyurethane dermal matrix used to reconstruct complex wounds including deep dermal and full‐thickness burns, necrotising fasciitis and free flap donor site. We hope to further explore its potential applications in this series.Methods: Patients who received BTM application across four centres over an 18‐month period were included. Patients were followed up to assess BTM and graft take, the aesthetic, the return of sensation and complications.Results: A total of 27 patients with 35 wounds were identified with a range of aetiologies. Thirty‐three wounds had 100% integration of BTM at the time of sealing membrane removal. Seven wounds had partial graft loss that later healed by secondary intention. In two cases, re‐epithelialisation occurred with BTM alone without split‐skin graft.Conclusion: BTM offers a safe and reliable reconstructive option in challenging wounds that would otherwise require more complex operations.