ISIna Gerhild Siller

Ina Gerhild Siller

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ina Gerhild Siller has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Customizable 3D-Printed (Co-)Cultivation Systems for In Vitro Study of Angiogenesis

    by Ina G. Siller, Niklas-Maximilian Epping, Antonina Lavrentieva, Thomas Scheper, Janina Bahnemann

    Due to the ever-increasing resolution of 3D printing technology, additive manufacturing is now even used to produce complex devices for laboratory applications. Personalized experimental devices or entire cultivation systems of almost unlimited complexity can potentially be manufactured within hours from start to finish—an enormous potential for experimental parallelization in a highly controllable environment. This study presents customized 3D-printed co-cultivation systems, which qualify for angiogenesis studies. In these systems, endothelial and mesenchymal stem cells (AD-MSC) were indirectly co-cultivated—that is, both cell types were physically separated through a rigid, 3D-printed barrier in the middle, while still sharing the same cell culture medium that allows for the exchange of signalling molecules. Biochemical-based cytotoxicity assays initially confirmed that the 3D printing material does not exert any negative effects on cells. Since the material also enables phase contrast and fluorescence microscopy, the behaviour of cells could be observed over the entire cultivation via both. Microscopic observations and subsequent quantitative analysis revealed that endothelial cells form tubular-like structures as angiogenic feature when indirectly co-cultured alongside AD-MSCs in the 3D-printed co-cultivation system. In addition, further 3D-printed devices are also introduced that address different issues and aspire to help in varying experimental setups. Our results mark an important step forward for the integration of customized 3D-printed systems as self-contained test systems or equipment in biomedical applications.


  • Open Access

    3D-Printed Flow Cells for Aptamer-Based Impedimetric Detection of E. coli Crooks Strain

    by Ina G. Siller, John-Alexander Preuss, Katharina Urmann, Michael R. Hoffmann, Thomas Scheper, Janina Bahnemann

    Electrochemical spectroscopy enables rapid, sensitive, and label-free analyte detection without the need of extensive and laborious labeling procedures and sample preparation. In addition, with the emergence of commercially available screen-printed electrodes (SPEs), a valuable, disposable alternative to costly bulk electrodes for electrochemical (bio-)sensor applications was established in recent years. However, applications with bare SPEs are limited and many applications demand additional/supporting structures or flow cells. Here, high-resolution 3D printing technology presents an ideal tool for the rapid and flexible fabrication of tailor-made, experiment-specific systems. In this work, flow cells for SPE-based electrochemical (bio-)sensor applications were designed and 3D printed. The successful implementation was demonstrated in an aptamer-based impedimetric biosensor approach for the detection of Escherichia coli (E. coli) Crooks strain as a proof of concept. Moreover, further developments towards a 3D-printed microfluidic flow cell with an integrated micromixer also illustrate the great potential of high-resolution 3D printing technology to enable homogeneous mixing of reagents or sample solutions in (bio-)sensor applications.


  • Open Access

    Characterization of a customized 3D-printed cell culture system using clear, translucent acrylate that enables optical online monitoring

    by Ina Gerhild Siller, Anton Enders, Pia Gellermann, Steffen Winkler, Antonina Lavrentieva, Thomas Scheper, Janina Bahnemann

    Cells are very sensitive to their direct environment—they place high demands, for example, on ambient culture medium, adjacent cell types, and the properties of surrounding material parts. As a result, mechanical and physical material properties—such as surface roughness, swelling, electrostatic effects, etc—can all have a significant impact on cell behaviour. In addition, a material’s composition also impacts whether that material meets biocompatibility requirements and can thus be considered for potential use in biomedical applications. The entry of high-resolution 3D printing technology in biotechnology has opened the door to individually-designed experiment-adaptable devices of almost unlimited complexity that can be manufactured within just a few hours. 3D printing materials are frequently lacking in the characteristics that make them suitable for biomedical applications, however. This study introduces a high-resolution polyacrylic 3D printing material as a potential alternative material for use in cultivation systems with indirect or direct contact to cells. Viability analyses, studies of apoptotic/necrotic cell death response, and surface studies all suggest that this material meets the requirements for (in vitro) biocompatibility, and has surface properties sufficient to permit uninhibited cell proliferation for cells in direct contact to the material. Moreover, the translucency of this material facilitates the type of optical monitoring required for performing experiments in a microfluidic environment, or for facilitating microscopic observations.


  • Open Access

    Real-Time Live-Cell Imaging Technology Enables High-Throughput Screening to Verify in Vitro Biocompatibility of 3D Printed Materials

    by Ina G. Siller, Anton Enders, Tobias Steinwedel, Niklas-Maximilian Epping, Marline Kirsch, Antonina Lavrentieva, Thomas Scheper, Janina Bahnemann

    With growing advances in three-dimensional (3D) printing technology, the availability and diversity of printing materials has rapidly increased over the last years. 3D printing has quickly become a useful tool for biomedical and various laboratory applications, offering a tremendous potential for efficiently fabricating complex devices in a short period of time. However, there still remains a lack of information regarding the impact of printing materials and post-processing techniques on cell behavior. This study introduces real-time live-cell imaging technology as a fast, user-friendly, and high-throughput screening strategy to verify the in vitro biocompatibility of 3D printed materials. Polyacrylate-based photopolymer material was printed using high-resolution 3D printing techniques, post-processed using three different procedures, and then analyzed with respect to its effects on cell viability, apoptosis, and necrosis of adipogenic mesenchymal stem cells (MSCs). When using ethanol for the post-processing procedure and disinfection, no significant effects on MSCs could be detected. For the analyses a novel image-based live-cell analysis system was compared against a biochemical-based standard plate reader assay and traditional flow cytometry. This comparison illustrates the superiority of using image-based detection of in vitro biocompatibility with respect to analysis time, usability, and scientific outcome.


  • Open Access

    Adenosine receptors regulate gap junction coupling of the human cerebral microvascular endothelial cells hCMEC/D3 by Ca2+influx through cyclic nucleotide‐gated channels

    by Almke Bader, Willem Bintig, Daniela Begandt, Anne Klett, Ina G. Siller, Carola Gregor, Frank Schaarschmidt, Babette Weksler, Ignacio Romero, Pierre‐Olivier Couraud, et al.

    Key points: Gap junction channels are essential for the formation and regulation of physiological units in tissues by allowing the lateral cell‐to‐cell diffusion of ions, metabolites and second messengers. Stimulation of the adenosine receptor subtype A2Bincreases the gap junction coupling in the human blood–brain barrier endothelial cell line hCMEC/D3. Although the increased gap junction coupling is cAMP‐dependent, neither the protein kinase A nor the exchange protein directly activated by cAMP were involved in this increase. We found that cAMP activates cyclic nucleotide‐gated (CNG) channels and thereby induces a Ca2+influx, which leads to the increase in gap junction coupling. The report identifies CNG channels as a possible physiological link between adenosine receptors and the regulation of gap junction channels in endothelial cells of the blood–brain barrier. The human cerebral microvascular endothelial cell line hCMEC/D3 was used to characterize the physiological link between adenosine receptors and the gap junction coupling in endothelial cells of the blood–brain barrier. Expressed adenosine receptor subtypes and connexin (Cx) isoforms were identified by RT‐PCR. Scrape loading/dye transfer was used to evaluate the impact of the A2Aand A2Badenosine receptor subtype agonist 2‐phenylaminoadenosine (2‐PAA) on the gap junction coupling. We found that 2‐PAA stimulated cAMP synthesis and enhanced gap junction coupling in a concentration‐dependent manner. This enhancement was accompanied by an increase in gap junction plaques formed by Cx43. Inhibition of protein kinase A did not affect the 2‐PAA‐related enhancement of gap junction coupling. In contrast, the cyclic nucleotide‐gated (CNG) channel inhibitorl‐cis‐diltiazem, as well as the chelation of intracellular Ca2+with BAPTA, or the absence of external Ca2+, suppressed the 2‐PAA‐related enhancement of gap junction coupling. Moreover, we observed a 2‐PAA‐dependent activation of CNG channels by a combination of electrophysiology and pharmacology. In conclusion, the stimulation of adenosine receptors in hCMEC/D3 cells induces a Ca2+influx by opening CNG channels in a cAMP‐dependent manner. Ca2+in turn induces the formation of new gap junction plaques and a consecutive sustained enhancement of gap junction coupling. The report identifies CNG channels as a physiological link that integrates gap junction coupling into the adenosine receptor‐dependent signalling of endothelial cells of the blood–brain barrier.