GTGiuseppe Trianni

Giuseppe Trianni

*This is an algorithmically generated author record based on publicly available information.

Giuseppe Trianni has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Transfemoral TAVI in a High-Risk Patient with Porcelain Aorta and Severe Subrenal Abdominal Aortic Stenosis: A Case Report

    by Anees Al Jabri, Marcello Ravani, Giuseppe Trianni, Tommaso Gasbarri, Marta Casula, Sergio Berti

    Aortic stenosis (AS) is a common degenerative valvular disease in elderly patients, causing obstruction of left ventricular outflow and presenting with symptoms such as angina, syncope, and heart failure. Although surgical aortic valve replacement (SAVR) remains the gold standard, its high perioperative risk in frail patients has led to the adoption of transcatheter aortic valve implantation (TAVI) as a less invasive and effective alternative. The transfemoral (TF) access route is generally preferred, but severe peripheral arterial disease may limit its feasibility. We report the case of a 71-year-old woman with critical AS complicated by multiple comorbidities, including extensive vascular calcifications, a porcelain aorta, and significant subrenal abdominal aortic stenosis. Multimodal imaging, including computed tomography, was essential for procedural planning, revealing complex iliofemoral anatomy unsuitable for conventional device passage without intervention. Intravascular lithotripsy (IVL) was used to disrupt calcific plaques and facilitate safe vascular access. The TAVI procedure was successfully performed under local anesthesia via TF access using a 65 cm GORE® DRYSEAL Flex Introducer Sheath (W. L. Gore & Associates, Flagstaff, AZ, USA) (18-Fr). After balloon valvuloplasty performed over a SAFARI2™ Pre-Shaped TAVI Guidewire, Extra Small (Boston Scientific, Marlborough, MA, USA) Curve in the left ventricle, a self-expanding Medtronic Evolut™ FX 26 (Medtronic, Minneapolis, MN, USA)mm transcatheter valve was implanted. Postoperative imaging confirmed optimal valve function and vascular integrity without complications. This case highlights the role of IVL as an innovative adjunctive technique enabling TF-TAVI in patients with challenging vascular anatomy, thereby expanding treatment options for high-risk individuals with severe AS.


  • Open Access

    Transcatheter Aortic Valve Replacement in Degenerated Perceval Bioprosthesis: Clinical and Technical Aspects in 32 Cases

    by Giovanni Concistrè, Tommaso Gasbarri, Marcello Ravani, Anees Al Jabri, Giuseppe Trianni, Giacomo Bianchi, Rafik Margaryan, Francesca Chiaramonti, Michele Murzi, Enkel Kallushi, et al.

    Background: Sutureless aortic bioprostheses are increasingly being used to provide shorter cross-clamp time and facilitate minimally invasive aortic valve replacement. As the use of sutureless valves has increased over the past decade, we begin to encounter their degeneration. We describe clinical outcomes and technical aspects in patients with degenerated sutureless Perceval (CorCym, Italy) aortic bioprosthesis treated with valve-in-valve transcatheter aortic valve replacement (VIV-TAVR). Methods: Between March 2011 and March 2023, 1310 patients underwent aortic valve replacement (AVR) with Perceval bioprosthesis implantation. Severe bioprosthesis degeneration treated with VIV-TAVR occurred in 32 patients with a mean of 6.4 ± 1.9 years (range: 2–10 years) after first implantation. Mean EuroSCORE II was 9.5 ± 6.4% (range: 1.9–35.1%). Results: Thirty of thirty-two (94%) VIV-TAVR were performed via transfemoral and two (6%) via transapical approach. Vascular complications occurred in two patients (6%), and mean hospital stay was 4.6 ± 2.4 days. At mean follow-up of 16.7 ± 15.2 months (range: 1–50 months), survival was 100%, and mean transvalvular pressure gradient was 18.7 ± 5.3 mmHg. Conclusion: VIV-TAVR is a useful option for degenerated Perceval and appears safe and effective. This procedure is associated with good clinical results and excellent hemodynamic performance in our largest single-center experience.