Yongjun Lai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yongjun Lai has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
Angelica Campigotto
Department of Mechanical and Materials Engineering, Queen’s University, Kingston, Canada
6 shared publicationsRick Helgason
Department of Mechanical and Materials Engineering, Queen’s University, Kingston, Ontario, Canada
5 shared publicationsKongying Xie
Dept. of Mechanical and Materials Engineering, Queen’s University, Kingston, ON, Canada K7L 3N6
4 shared publicationsJino Fathy
Department of Mechanical and Materials Engineering, Queens University, Kingston, ON, Canada
3 shared publications- Muhammad Masood Ul Hassan
Department of Chemical and Materials Engineering, Pakistan Institute of Engineering & Applied Sciences, P.O. Nilore, Islamabad, Pakistan
3 shared publications - Rana Iqtidar Shakoor
Department of Chemical and Materials Engineering, Pakistan Institute of Engineering & Applied Sciences, P.O. Nilore, Islamabad, Pakistan
3 shared publications
Latest Publications
- Open Access
- 27 October 2026
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
A tunable resonant electromagnetic vibration energy harvester and power management system for wireless sensor networks
Vibration energy harvesters (VEHs) convert vibrational energy into electrical energy and can be used to power wireless sensor networks (WSNs) for machine condition monitoring. However, there are challenges in the development of practical VEHs, including matching the resonant frequency, maximizing the converted energy, and managing power storage and delivery for WSN nodes. This paper presents a tunable resonant electromagnetic VEH transducer and power management system to address these challenges. The transducer is composed of cylindrical magnets, an enclosed back iron, an internal coil, and a circular flat spring. The resonant frequency is tunable by rotating a support structure to vary the length of the spring and therefore the spring constant. This tuning architecture allows for a wide resonant frequency range and a compact enclosure. The transducer was modeled, simulated, and tested experimentally. In testing, the transducer demonstrated a tunable resonant frequency range of 93 Hz, from 45 to 138 Hz. The transducer was then tuned to 60 Hz, and independent tests were performed in vibrations of 60 Hz and 0.3 g RMS acceleration. The transducer generated 3.93 mW over an optimal resistive load. In separate integrated system tests, the power management system delivered 1.76 mW to the battery and 1.56 mW to the regulated supply. The presented system and investigation contribute to the development of practical VEH technology for powering WSN nodes.
- 27 October 2026
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
Open AccessA tunable resonant electromagnetic vibration energy harvester and power management system for wireless sensor networks
Vibration energy harvesters (VEHs) convert vibrational energy into electrical energy and can be used to power wireless sensor networks (WSNs) for machine condition monitoring. However, there are challenges in the development of practical VEHs, including matching the resonant frequency, maximizing the converted energy, and managing power storage and delivery for WSN nodes. This paper presents a tunable resonant electromagnetic VEH transducer and power management system to address these challenges. The transducer is composed of cylindrical magnets, an enclosed back iron, an internal coil, and a circular flat spring. The resonant frequency is tunable by rotating a support structure to vary the length of the spring and therefore the spring constant. This tuning architecture allows for a wide resonant frequency range and a compact enclosure. The transducer was modeled, simulated, and tested experimentally. In testing, the transducer demonstrated a tunable resonant frequency range of 93 Hz, from 45 to 138 Hz. The transducer was then tuned to 60 Hz, and independent tests were performed in vibrations of 60 Hz and 0.3 g RMS acceleration. The transducer generated 3.93 mW over an optimal resistive load. In separate integrated system tests, the power management system delivered 1.76 mW to the battery and 1.56 mW to the regulated supply. The presented system and investigation contribute to the development of practical VEH technology for powering WSN nodes.
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (20) , 30229-30237
A Microfluidic Contact Lens With Optimized Channel Placement for Enhanced Sensitivity for Continuous Intraocular Pressure Monitoring
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (20) , 30229-30237
A Microfluidic Contact Lens With Optimized Channel Placement for Enhanced Sensitivity for Continuous Intraocular Pressure Monitoring
- 8 July 2026
- Published by Springer Nature
- p. 222-227
A Deep Learning Framework for Vision-Based Intraocular Pressure Monitoring Using Microfluidic Contact Lenses
- 8 July 2026
- Published by Springer Nature
- p. 222-227
A Deep Learning Framework for Vision-Based Intraocular Pressure Monitoring Using Microfluidic Contact Lenses
- Open Access
- 29 October 2025
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 241
Transducer configurations for enhanced power density in cylindrical electromagnetic vibration energy harvesters
- 29 October 2025
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 241
Open AccessTransducer configurations for enhanced power density in cylindrical electromagnetic vibration energy harvesters
- Open Access
Comb-Tipped Coupled Cantilever Sensor for Enhanced Real-Time Detection of E. coli Bacteria
The detection of particulate matter, particularly pathogenic bacteria, is essential in environmental monitoring, food safety, and clinical diagnostics. Among the various sensing techniques used, cantilever-based sensors offer a promising platform for label-free, real-time detection due to their high sensitivity. Here, we present a coupled cantilever sensor incorporating interdigitated comb-shaped structures to enhance dielectrophoretic (DEP) capture of Escherichia coli in liquid samples. During operation, one cantilever is externally actuated and the other oscillates passively through fluid-mediated coupling. The sensor was experimentally evaluated across a broad concentration range from 10 to 105 cells/mL and the resonant frequency shifts were recorded for both beams. The results showed a strong linear frequency shift across all tested concentrations, without saturation. This demonstrates the sensor’s ability to detect both trace and high bacterial loads without needing recalibration. High frequency shifts of 4863 Hz were recorded for 105 cells/mL and 225 Hz for the lowest concentration of 10 cells/mL, giving a limit of detection of 10 cells/mL. The sensor also showed a higher signal to noise ratio of 265.7 compared to previously reported designs. These findings showed that the enhanced sensor design enables sensitive, linear, and reliable bioparticle detection across a wide range, making it suitable for diverse applications.
Open AccessComb-Tipped Coupled Cantilever Sensor for Enhanced Real-Time Detection of E. coli Bacteria
The detection of particulate matter, particularly pathogenic bacteria, is essential in environmental monitoring, food safety, and clinical diagnostics. Among the various sensing techniques used, cantilever-based sensors offer a promising platform for label-free, real-time detection due to their high sensitivity. Here, we present a coupled cantilever sensor incorporating interdigitated comb-shaped structures to enhance dielectrophoretic (DEP) capture of Escherichia coli in liquid samples. During operation, one cantilever is externally actuated and the other oscillates passively through fluid-mediated coupling. The sensor was experimentally evaluated across a broad concentration range from 10 to 105 cells/mL and the resonant frequency shifts were recorded for both beams. The results showed a strong linear frequency shift across all tested concentrations, without saturation. This demonstrates the sensor’s ability to detect both trace and high bacterial loads without needing recalibration. High frequency shifts of 4863 Hz were recorded for 105 cells/mL and 225 Hz for the lowest concentration of 10 cells/mL, giving a limit of detection of 10 cells/mL. The sensor also showed a higher signal to noise ratio of 265.7 compared to previously reported designs. These findings showed that the enhanced sensor design enables sensitive, linear, and reliable bioparticle detection across a wide range, making it suitable for diverse applications.
- Open Access
- 1 June 2025
- Published by IOP Publishing in Flexible and Printed Electronics
- Vol. 10 (2) , 025008
Silver nanowire infused hydrogel contact lenses for non-invasive intraocular pressure monitoring
Flexible, hydrogel-based materials are now vital in advanced diagnostic devices, particularly in smart contact lenses for continuous health monitoring. This study introduces a novel composite material by infusing silver nanowires (AgNWs) into a hydrogel polymer, creating a flexible, sensitive contact lens capable of continuous intraocular pressure (IOP) monitoring. The fabrication process is streamlined to integrate seamlessly with industrial production, promoting scalability and mass manufacture. The effect of AgNW integration on the hydrogel’s Young’s modulus was assessed through tensile testing of flat sheet samples at 5%, 3%, and 1% nanowire concentrations by weight, yielding modulus values of 2.517, 2.081, and 1.669 MPa, respectively, with stiffness increasing alongside AgNW concentration. The device functions by detecting frequency shifts caused by impedance changes from structural reconfiguration of the nanowire network under applied pressure. To evaluate performance, lenses of various concentrations were rigorously tested for stability, repeatability, and sensitivity using synthetic, porcine, and human cadaveric eye models. Results indicated that higher AgNW concentrations achieved greater sensitivity, with peak sensitivities of 12, 30, and 18 kHz mmHg−1 recorded at a 5% concentration across the testing models. This material represents a promising candidate for scalable, high-performance IOP monitoring applications.
- 1 June 2025
- Published by IOP Publishing in Flexible and Printed Electronics
- Vol. 10 (2) , 025008
Open AccessSilver nanowire infused hydrogel contact lenses for non-invasive intraocular pressure monitoring
Flexible, hydrogel-based materials are now vital in advanced diagnostic devices, particularly in smart contact lenses for continuous health monitoring. This study introduces a novel composite material by infusing silver nanowires (AgNWs) into a hydrogel polymer, creating a flexible, sensitive contact lens capable of continuous intraocular pressure (IOP) monitoring. The fabrication process is streamlined to integrate seamlessly with industrial production, promoting scalability and mass manufacture. The effect of AgNW integration on the hydrogel’s Young’s modulus was assessed through tensile testing of flat sheet samples at 5%, 3%, and 1% nanowire concentrations by weight, yielding modulus values of 2.517, 2.081, and 1.669 MPa, respectively, with stiffness increasing alongside AgNW concentration. The device functions by detecting frequency shifts caused by impedance changes from structural reconfiguration of the nanowire network under applied pressure. To evaluate performance, lenses of various concentrations were rigorously tested for stability, repeatability, and sensitivity using synthetic, porcine, and human cadaveric eye models. Results indicated that higher AgNW concentrations achieved greater sensitivity, with peak sensitivities of 12, 30, and 18 kHz mmHg−1 recorded at a 5% concentration across the testing models. This material represents a promising candidate for scalable, high-performance IOP monitoring applications.
- 4 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (2) , 1313-1321
Real-Time Ultralow Bacterial Detection With A Gap-Method Microcantilever Biosensor
Detecting ultra-low concentrations of pathogenic bacteria is important for public health, environmental monitoring, and therapeutic research. This study presents the development and testing of a microcantilever biosensor based on the gap method for the detection of E. coli and P. aeruginosa bacteria in water. The biosensor utilizes dielectrophoresis force to attract bacteria to the gap area for real-time detection of extremely low bacteria concentrations (10 cells/mL) within a 7-minute timeframe. This design demonstrates excellent performance with a low limit of detection (<10 cells/mL), high sensitivity (minimum sensitivity of 2.59 pg/Hz), and a high signal-to-noise ratio (minimum SNR of 23.38). In addition, the surface of the biosensor was functionalized with pyoverdine, a siderophore of pseudomonas bacteria. The test results show that the surface functionalization was effective, and that the frequency shift of the functionalized microcantilever was much higher when testing P. aeruginosa compared to the testing with E. coli bacteria.
- 4 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (2) , 1313-1321
Real-Time Ultralow Bacterial Detection With A Gap-Method Microcantilever Biosensor
Detecting ultra-low concentrations of pathogenic bacteria is important for public health, environmental monitoring, and therapeutic research. This study presents the development and testing of a microcantilever biosensor based on the gap method for the detection of E. coli and P. aeruginosa bacteria in water. The biosensor utilizes dielectrophoresis force to attract bacteria to the gap area for real-time detection of extremely low bacteria concentrations (10 cells/mL) within a 7-minute timeframe. This design demonstrates excellent performance with a low limit of detection (<10 cells/mL), high sensitivity (minimum sensitivity of 2.59 pg/Hz), and a high signal-to-noise ratio (minimum SNR of 23.38). In addition, the surface of the biosensor was functionalized with pyoverdine, a siderophore of pseudomonas bacteria. The test results show that the surface functionalization was effective, and that the frequency shift of the functionalized microcantilever was much higher when testing P. aeruginosa compared to the testing with E. coli bacteria.
- Open Access
- 8 May 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 35 (1) , 15
Contact Lens-Based Intraocular Pressure Sensor
The intraocular pressure (IOP) is the principal indicator for diagnosis of glaucoma which is one of the leading causes of blindness. The IOP can vary throughout the day, and traditional methods of measuring it in a clinical setting only provide a fraction of the patient’s IOP pattern. This article presents a cost-effective way for continuous monitoring of IOP by utilizing a soft contact lens with strategically placed holes. The deformation of these holes due to the change in IOP can be used to detect the pressure variations throughout the day. Extensive COMSOL Multiphysics simulations are conducted to optimize the design and to test the viability of this method. The optimized lens design can achieve a large deformation ratio sensitivity of 0.39 per mmHg with an applied pressure range of 10 mmHg to 40 mmHg.
- 8 May 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 35 (1) , 15
Open AccessContact Lens-Based Intraocular Pressure Sensor
The intraocular pressure (IOP) is the principal indicator for diagnosis of glaucoma which is one of the leading causes of blindness. The IOP can vary throughout the day, and traditional methods of measuring it in a clinical setting only provide a fraction of the patient’s IOP pattern. This article presents a cost-effective way for continuous monitoring of IOP by utilizing a soft contact lens with strategically placed holes. The deformation of these holes due to the change in IOP can be used to detect the pressure variations throughout the day. Extensive COMSOL Multiphysics simulations are conducted to optimize the design and to test the viability of this method. The optimized lens design can achieve a large deformation ratio sensitivity of 0.39 per mmHg with an applied pressure range of 10 mmHg to 40 mmHg.
- 14 November 2022
- Published by SAGE Publications in Journal of Micromanufacturing
- Vol. 6 (1) , 60-65
The effect of laser cutting on the Young’s modulus of Polydimethylsiloxane
Laser cutting is often used in the fabrication of Polydimethylsiloxane (PDMS) substrates for novel microdevices such as wearable sensors and microfluidic devices. PDMS is a thermosetting polymer whose material properties are affected by the thermal conditions during the curing process. Since laser cutting exposes the cutting material to high temperatures, this might affect the heat-sensitive material properties. In this work, we examine how laser cutting affects the stiffness of PDMS by measuring the Young’s modulus of PDMS and comparing that to the Young’s modulus of laser-cut PDMS. We find an increase in the Young’s modulus from 0.34 to 0.37 MPa (9%) for PDMS mixed at a ratio of 20:1 base to curing agent. For 10:1 ratio PDMS, we find the increase in Young’s modulus is 31%, from 1.02 to 1.34 MPa.
- 14 November 2022
- Published by SAGE Publications in Journal of Micromanufacturing
- Vol. 6 (1) , 60-65
The effect of laser cutting on the Young’s modulus of Polydimethylsiloxane
Laser cutting is often used in the fabrication of Polydimethylsiloxane (PDMS) substrates for novel microdevices such as wearable sensors and microfluidic devices. PDMS is a thermosetting polymer whose material properties are affected by the thermal conditions during the curing process. Since laser cutting exposes the cutting material to high temperatures, this might affect the heat-sensitive material properties. In this work, we examine how laser cutting affects the stiffness of PDMS by measuring the Young’s modulus of PDMS and comparing that to the Young’s modulus of laser-cut PDMS. We find an increase in the Young’s modulus from 0.34 to 0.37 MPa (9%) for PDMS mixed at a ratio of 20:1 base to curing agent. For 10:1 ratio PDMS, we find the increase in Young’s modulus is 31%, from 1.02 to 1.34 MPa.