Peter J. Sterk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Peter J. Sterk has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Anirban Sinha
Department of Pulmonary Medicine, Amsterdam University Medical Centers, Location Academic Medical Center, University of Amsterdam, 1105 AZ Amsterdam, The Netherlands
3 shared publications - René Lutter
Department of Experimental Immunology, Amsterdam UMC, location AMC University of Amsterdam Amsterdam the Netherlands
3 shared publications - Anke-Hilse Maitland-Van der Zee
Department of Pulmonary Medicine, Amsterdam UMC University of Amsterdam Amsterdam The Netherlands
2 shared publications - Barbara Dierdorp
Amsterdam UMC, Department of Experimental Immunology, University of Amsterdam and Amsterdam Infection & Immunity Institute, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands
2 shared publications - Edgar Delgado-Eckert
Paediatric Research Centre, University Children’s Hospital Basel UKBB, University of Basel, Basel, Switzerland
2 shared publications - Rianne de Vries
Breathomix BV, Bargelaan 200, Leiden, CW 2333, The Netherlands
2 shared publications
Latest Publications
- Open Access
Analysis of Exosomal MicroRNA Dynamics in Response to Rhinovirus Challenge in a Longitudinal Case-Control Study of Asthma
Asthma symptoms are often exacerbated by the common-cold-causing rhinovirus (RV). In this study, we characterized the temporal behavior of circulating exosomal microRNAs (ExoMiRNAs) in a longitudinal bi-phasic case-control study of mild asthmatics (n = 12) and matched non-atopic healthy controls (n = 12) inoculated with rhinovirus. We aimed to define clinical and immunologic characteristics associated with differentially expressed (DE) miRNAs. In total, 26 DE ExoMiRNAs, including hsa-let-7f-5p, hsa-let-7a-5p, hsa-miR-122-5p, hsa-miR-101-3p, and hsa-miR-126-3p, were identified between asthmatic and healthy subjects after inoculation with RV. Time series clustering identified a unique Cluster of Upregulated DE ExoMiRNAs with augmenting mean expression and a distinct Cluster of Downregulated DE ExoMiRNAs with mean expression decline in asthmatic subjects upon RV challenge. Notably, the Upregulated Cluster correlated with Th1 and interferon-induced cytokines/chemokines (IFN- and IFN--inducible protein-10) and interleukin-10 (IL-10). Conversely, the Downregulated Cluster correlated with IL-13, a Th2 cytokine, pulmonary function measurements (FVC%, FEV1%, and PEF%), and inflammatory biomarkers (FeNO, eosinophil%, and neutrophil%). Key ExoMiRNA–target gene and anti-viral defense mechanisms of the Upregulated and Downregulated Clusters were identified by network and gene enrichment analyses. Our findings provide insight into the regulatory role of ExoMiRNAs in RV-induced asthma.Open AccessAnalysis of Exosomal MicroRNA Dynamics in Response to Rhinovirus Challenge in a Longitudinal Case-Control Study of Asthma
Asthma symptoms are often exacerbated by the common-cold-causing rhinovirus (RV). In this study, we characterized the temporal behavior of circulating exosomal microRNAs (ExoMiRNAs) in a longitudinal bi-phasic case-control study of mild asthmatics (n = 12) and matched non-atopic healthy controls (n = 12) inoculated with rhinovirus. We aimed to define clinical and immunologic characteristics associated with differentially expressed (DE) miRNAs. In total, 26 DE ExoMiRNAs, including hsa-let-7f-5p, hsa-let-7a-5p, hsa-miR-122-5p, hsa-miR-101-3p, and hsa-miR-126-3p, were identified between asthmatic and healthy subjects after inoculation with RV. Time series clustering identified a unique Cluster of Upregulated DE ExoMiRNAs with augmenting mean expression and a distinct Cluster of Downregulated DE ExoMiRNAs with mean expression decline in asthmatic subjects upon RV challenge. Notably, the Upregulated Cluster correlated with Th1 and interferon-induced cytokines/chemokines (IFN- and IFN--inducible protein-10) and interleukin-10 (IL-10). Conversely, the Downregulated Cluster correlated with IL-13, a Th2 cytokine, pulmonary function measurements (FVC%, FEV1%, and PEF%), and inflammatory biomarkers (FeNO, eosinophil%, and neutrophil%). Key ExoMiRNA–target gene and anti-viral defense mechanisms of the Upregulated and Downregulated Clusters were identified by network and gene enrichment analyses. Our findings provide insight into the regulatory role of ExoMiRNAs in RV-induced asthma. - 18 August 2021
- Published by Wiley in Pediatric Allergy and Immunology
- Vol. 33 (1) , e13612
Prediction of asthma in early preschool wheezing by electronic nose analysis
- 18 August 2021
- Published by Wiley in Pediatric Allergy and Immunology
- Vol. 33 (1) , e13612
Prediction of asthma in early preschool wheezing by electronic nose analysis
- Open Access
The Influence of Smoking Status on Exhaled Breath Profiles in Asthma and COPD Patients
Breath analysis using eNose technology can be used to discriminate between asthma and COPD patients, but it remains unclear whether results are influenced by smoking status. We aim to study whether eNose can discriminate between ever- vs. never-smokers and smoking 24 h before the exhaled breath, and if smoking can be considered a confounder that influences eNose results. We performed a cross-sectional analysis in adults with asthma or chronic obstructive pulmonary disease (COPD), and healthy controls. Ever-smokers were defined as patients with current or past smoking habits. eNose measurements were performed by using the SpiroNose. The principal component (PC) described the eNose signals, and linear discriminant analysis determined if PCs classified ever-smokers vs. never-smokers and smoking 24 h. The area under the receiver–operator characteristic curve (AUC) assessed the accuracy of the models. We selected 593 ever-smokers (167 smoked <24 h before measurement) and 303 never-smokers and measured the exhaled breath profiles of discriminated ever- and never-smokers (AUC: 0.74; 95% CI: 0.66–0.81), and no cigarette consumption <24h (AUC 0.54, 95% CI: 0.43–0.65). In healthy controls, the eNose did not discriminate between ever or never-smokers (AUC 0.54; 95% CI: 0.49–0.60) and recent cigarette consumption (AUC 0.60; 95% CI: 0.50–0.69). The eNose could distinguish between ever and never-smokers in asthma and COPD patients, but not recent smokers. Recent smoking is not a confounding factor of eNose breath profiles.
Open AccessThe Influence of Smoking Status on Exhaled Breath Profiles in Asthma and COPD Patients
Breath analysis using eNose technology can be used to discriminate between asthma and COPD patients, but it remains unclear whether results are influenced by smoking status. We aim to study whether eNose can discriminate between ever- vs. never-smokers and smoking 24 h before the exhaled breath, and if smoking can be considered a confounder that influences eNose results. We performed a cross-sectional analysis in adults with asthma or chronic obstructive pulmonary disease (COPD), and healthy controls. Ever-smokers were defined as patients with current or past smoking habits. eNose measurements were performed by using the SpiroNose. The principal component (PC) described the eNose signals, and linear discriminant analysis determined if PCs classified ever-smokers vs. never-smokers and smoking 24 h. The area under the receiver–operator characteristic curve (AUC) assessed the accuracy of the models. We selected 593 ever-smokers (167 smoked <24 h before measurement) and 303 never-smokers and measured the exhaled breath profiles of discriminated ever- and never-smokers (AUC: 0.74; 95% CI: 0.66–0.81), and no cigarette consumption <24h (AUC 0.54, 95% CI: 0.43–0.65). In healthy controls, the eNose did not discriminate between ever or never-smokers (AUC 0.54; 95% CI: 0.49–0.60) and recent cigarette consumption (AUC 0.60; 95% CI: 0.50–0.69). The eNose could distinguish between ever and never-smokers in asthma and COPD patients, but not recent smokers. Recent smoking is not a confounding factor of eNose breath profiles.
- Open Access
Ruling out SARS-CoV-2 infection using exhaled breath analysis by electronic nose in a public health setting
Background: Rapid and accurate detection of SARS-CoV-2 infected individuals is crucial for taking timely measures and minimizing the risk of further SARS-CoV-2 spread. We aimed to assess the accuracy of exhaled breath analysis by electronic nose (eNose) for the discrimination between individuals with and without a SARS-CoV-2 infection. Methods: This was a prospective real-world study of individuals presenting to public test facility for SARS-CoV-2 detection by molecular amplification tests (TMA or RT-PCR). After sampling of a combined throat/nasopharyngeal swab, breath profiles were obtained using a cloud-connected eNose. Data-analysis involved advanced signal processing and statistics based on independent t-tests followed by linear discriminant and ROC analysis. Data from the training set were tested in a validation , a replication and an asymptomatic set . Findings: For the analysis 4510 individuals were available. In the training set (35 individuals with; 869 without SARS-CoV-2), the eNose sensors were combined into a composite biomarker with a ROC-AUC of 0.947 (CI:0.928-0.967). These results were confirmed in the validation set (0.957; CI:0.942-0.971, n=904) and externally validated in the replication set (0.937; CI:0.926-0.947, n=1948) and the asymptomatic set (0.909; CI:0.879-0.938, n=754). Selecting a cut-off value of 0.30 in the training set resulted in a sensitivity/specificity of 100/78, >99/84, 98/82% in the validation, replication and asymptomatic set , respectively. Interpretation: eNose represents a quick and non-invasive method to reliably rule out SARS-CoV-2 infection in public health test facilities and can be used as a screening test to define who needs an additional confirmation test. Funding: Ministry of Health, Welfare and Sport Research in context: Evidence before this study: Electronic nose technology is an emerging diagnostic tool for diagnosis and phenotyping of a wide variety of diseases, including inflammatory respiratory diseases, lung cancer, and infections. As of Feb 13, 2021, our search of PubMed using keywords “COVID-19” OR “SARS-CoV-2” AND “eNose” OR “electronic nose” OR “exhaled breath analysis” yielded 4 articles (1-4) that have assessed test characteristics of electronic nose to diagnose COVID-19. In these small studies the obtained signals using sensor-based technologies, two-dimensional gas chromatography and time-of-flight mass spectrometry, or proton transfer reaction time-of-flight mass spectrometry, provided adequate discrimination between patients with and without COVID-19. Added value of this study: We prospectively studied the accuracy of exhaled breath analysis by electronic nose (eNose) to diagnose or rule out a SARS-CoV-2 infection in individuals with and without symptoms presenting to a public test facility. In the training set with 904 individuals, the eNose sensors were combined into a composite biomarker with a ROC-AUC of 0.948. In three independent validation cohorts of 3606 individuals in total, eNose was able to reliably rule out SARS-CoV-2 infection in 70-75% of individuals, with a sensitivity ranging between 98-100%, and a specificity between 78-84%. No association was found between cycle thresholds values, as semi-quantitative measure of viral load, and eNose variables. Implications of all the available evidence: The available findings, including those from our study, support the use of eNose technology to distinguish between individuals with and without a SARS-CoV-2 infection with high accuracy. Exhaled breath analysis by eNose represents a quick and non-invasive method to reliably rule out a SARS-CoV-2 infection in public health test facilities. The results can be made available within seconds and can therefore be used as screening instrument. The eNose can reliably rule out a SARS-CoV-2 infection, eliminating the need for additional time-consuming, stressful, and expensive diagnostic tests in the majority of individuals.
Open AccessRuling out SARS-CoV-2 infection using exhaled breath analysis by electronic nose in a public health setting
Background: Rapid and accurate detection of SARS-CoV-2 infected individuals is crucial for taking timely measures and minimizing the risk of further SARS-CoV-2 spread. We aimed to assess the accuracy of exhaled breath analysis by electronic nose (eNose) for the discrimination between individuals with and without a SARS-CoV-2 infection. Methods: This was a prospective real-world study of individuals presenting to public test facility for SARS-CoV-2 detection by molecular amplification tests (TMA or RT-PCR). After sampling of a combined throat/nasopharyngeal swab, breath profiles were obtained using a cloud-connected eNose. Data-analysis involved advanced signal processing and statistics based on independent t-tests followed by linear discriminant and ROC analysis. Data from the training set were tested in a validation , a replication and an asymptomatic set . Findings: For the analysis 4510 individuals were available. In the training set (35 individuals with; 869 without SARS-CoV-2), the eNose sensors were combined into a composite biomarker with a ROC-AUC of 0.947 (CI:0.928-0.967). These results were confirmed in the validation set (0.957; CI:0.942-0.971, n=904) and externally validated in the replication set (0.937; CI:0.926-0.947, n=1948) and the asymptomatic set (0.909; CI:0.879-0.938, n=754). Selecting a cut-off value of 0.30 in the training set resulted in a sensitivity/specificity of 100/78, >99/84, 98/82% in the validation, replication and asymptomatic set , respectively. Interpretation: eNose represents a quick and non-invasive method to reliably rule out SARS-CoV-2 infection in public health test facilities and can be used as a screening test to define who needs an additional confirmation test. Funding: Ministry of Health, Welfare and Sport Research in context: Evidence before this study: Electronic nose technology is an emerging diagnostic tool for diagnosis and phenotyping of a wide variety of diseases, including inflammatory respiratory diseases, lung cancer, and infections. As of Feb 13, 2021, our search of PubMed using keywords “COVID-19” OR “SARS-CoV-2” AND “eNose” OR “electronic nose” OR “exhaled breath analysis” yielded 4 articles (1-4) that have assessed test characteristics of electronic nose to diagnose COVID-19. In these small studies the obtained signals using sensor-based technologies, two-dimensional gas chromatography and time-of-flight mass spectrometry, or proton transfer reaction time-of-flight mass spectrometry, provided adequate discrimination between patients with and without COVID-19. Added value of this study: We prospectively studied the accuracy of exhaled breath analysis by electronic nose (eNose) to diagnose or rule out a SARS-CoV-2 infection in individuals with and without symptoms presenting to a public test facility. In the training set with 904 individuals, the eNose sensors were combined into a composite biomarker with a ROC-AUC of 0.948. In three independent validation cohorts of 3606 individuals in total, eNose was able to reliably rule out SARS-CoV-2 infection in 70-75% of individuals, with a sensitivity ranging between 98-100%, and a specificity between 78-84%. No association was found between cycle thresholds values, as semi-quantitative measure of viral load, and eNose variables. Implications of all the available evidence: The available findings, including those from our study, support the use of eNose technology to distinguish between individuals with and without a SARS-CoV-2 infection with high accuracy. Exhaled breath analysis by eNose represents a quick and non-invasive method to reliably rule out a SARS-CoV-2 infection in public health test facilities. The results can be made available within seconds and can therefore be used as screening instrument. The eNose can reliably rule out a SARS-CoV-2 infection, eliminating the need for additional time-consuming, stressful, and expensive diagnostic tests in the majority of individuals.
- 1 November 2020
- Published by Elsevier in Journal of Allergy and Clinical Immunology
- Vol. 146 (5) , 995-996
eNose breathprints as composite biomarker for real-time phenotyping of complex respiratory diseases
- 1 November 2020
- Published by Elsevier in Journal of Allergy and Clinical Immunology
- Vol. 146 (5) , 995-996
eNose breathprints as composite biomarker for real-time phenotyping of complex respiratory diseases
- Open Access
Can Measurements of Inflammatory Biomarkers Be Used to Spot Respiratory Viral Infections?
Accurate detection of human respiratory viral infections is highly topical. We investigated how strongly inflammatory biomarkers (FeNO, eosinophils, neutrophils, and cytokines in nasal lavage fluid) and lung function parameters change upon rhinovirus 16 infection, in order to explore their potential use for infection detection. To this end, within a longitudinal cohort study, healthy and mildly asthmatic volunteers were experimentally inoculated with rhinovirus 16, and time series of these parameters/biomarkers were systematically recorded and compared between the pre- and post-infection phases of the study, which lasted two months and one month, respectively. We found that the parameters’/biomarkers’ ability to discriminate between the infected and the uninfected state varied over the observation time period. Consistently over time, the concentration of cytokines, in nasal lavage fluid, showed moderate to very good discrimination performance, thereby qualifying for disease progression monitoring, whereas lung function and FeNO, while quickly and non-invasively measurable using cheap portable devices (e.g., at airports), performed poorly.
Open AccessCan Measurements of Inflammatory Biomarkers Be Used to Spot Respiratory Viral Infections?
Accurate detection of human respiratory viral infections is highly topical. We investigated how strongly inflammatory biomarkers (FeNO, eosinophils, neutrophils, and cytokines in nasal lavage fluid) and lung function parameters change upon rhinovirus 16 infection, in order to explore their potential use for infection detection. To this end, within a longitudinal cohort study, healthy and mildly asthmatic volunteers were experimentally inoculated with rhinovirus 16, and time series of these parameters/biomarkers were systematically recorded and compared between the pre- and post-infection phases of the study, which lasted two months and one month, respectively. We found that the parameters’/biomarkers’ ability to discriminate between the infected and the uninfected state varied over the observation time period. Consistently over time, the concentration of cytokines, in nasal lavage fluid, showed moderate to very good discrimination performance, thereby qualifying for disease progression monitoring, whereas lung function and FeNO, while quickly and non-invasively measurable using cheap portable devices (e.g., at airports), performed poorly.
- Open Access
Airway expression of SARS-CoV-2 receptor, ACE2, and proteases, TMPRSS2 and furin, in severe asthma
Summary: Background: Patients with severe asthma may have a greater risk of dying from COVID-19 disease caused by SARS-CoV-2 virus. Angiotensin converting enzyme 2 (ACE2) receptor and enzyme proteases, transmembrane protease, serine 2 (TMPRSS2) and furin are needed for the attachment and invasion of the virus into host cells. We determined whether their expression in the airways of severe asthma patients is increased. Method: We examined the microarray mRNA expression of ACE2, TMPRSS2 and furin in the sputum, bronchial brush and bronchial biopsies of participants in the European U-BIOPRED cohort. Results: ACE2 and furin sputum gene expression was significantly increased in severe non-smoking asthma compared to mild-moderate asthma and healthy volunteers. By contrast, TMPRSS2 expression in bronchial biopsy and bronchial brushings was increased in severe smoking and ex-smoking asthmatics, and so was furin expression in bronchial brushings. Several clinical parameters including male gender, oral steroid use and nasal polyps were positively associated with ACE2, TMPRSS2 and furin expression levels. There was a higher expression of ACE2 and furin in the sputum neutrophilic molecular phenotype with inflammasome activation compared to the eosinophilic Type2-high or paucigranulocytic phenotypes. The enrichment score of the IL-13-Type2 gene signature was positively correlated with ACE2, TMPRSS2 and furin levels. Conclusion: These key determinants of virus entry into the lungs may contribute to the poorer outcomes from COVID-19 disease in patients with severe asthma. “take home” message: In severe asthma, gene expression of ACE, TMPRSS2 and furin are elevated compared to mild-moderate asthma and healthy volunteers, particularly in neutrophilic asthma. This might explain the increased risk of death in severe asthma afflicted with COVID19.
Open AccessAirway expression of SARS-CoV-2 receptor, ACE2, and proteases, TMPRSS2 and furin, in severe asthma
Summary: Background: Patients with severe asthma may have a greater risk of dying from COVID-19 disease caused by SARS-CoV-2 virus. Angiotensin converting enzyme 2 (ACE2) receptor and enzyme proteases, transmembrane protease, serine 2 (TMPRSS2) and furin are needed for the attachment and invasion of the virus into host cells. We determined whether their expression in the airways of severe asthma patients is increased. Method: We examined the microarray mRNA expression of ACE2, TMPRSS2 and furin in the sputum, bronchial brush and bronchial biopsies of participants in the European U-BIOPRED cohort. Results: ACE2 and furin sputum gene expression was significantly increased in severe non-smoking asthma compared to mild-moderate asthma and healthy volunteers. By contrast, TMPRSS2 expression in bronchial biopsy and bronchial brushings was increased in severe smoking and ex-smoking asthmatics, and so was furin expression in bronchial brushings. Several clinical parameters including male gender, oral steroid use and nasal polyps were positively associated with ACE2, TMPRSS2 and furin expression levels. There was a higher expression of ACE2 and furin in the sputum neutrophilic molecular phenotype with inflammasome activation compared to the eosinophilic Type2-high or paucigranulocytic phenotypes. The enrichment score of the IL-13-Type2 gene signature was positively correlated with ACE2, TMPRSS2 and furin levels. Conclusion: These key determinants of virus entry into the lungs may contribute to the poorer outcomes from COVID-19 disease in patients with severe asthma. “take home” message: In severe asthma, gene expression of ACE, TMPRSS2 and furin are elevated compared to mild-moderate asthma and healthy volunteers, particularly in neutrophilic asthma. This might explain the increased risk of death in severe asthma afflicted with COVID19.
- Open Access
Loss of adaptive capacity in asthmatics revealed by biomarker fluctuation dynamics upon experimental rhinovirus challenge
Asthma is a dynamic disease, in which lung mechanical and inflammatory processes often interact in a complex, unpredictable manner. We hypothesize that this may be explained by respiratory disease-related systems instability and loss of adaptability to changing environmental conditions, resulting in highly fluctuating biomarkers and symptoms. Using time series of inflammatory (eosinophils, neutrophils, FeNO), clinical and lung function biomarkers (PEF, FVC, and FEV 1 ), we estimated this loss of adaptive capacity (AC) during an experimental perturbation with a rhinovirus in 24 healthy and asthmatic volunteers. Loss of AC was estimated by comparing similarities between pre- and post-challenge time series. Unlike healthy participants, the asthmatic’s post-viral-challenge state resembled significantly more other rhinovirus-infected asthmatics than their own pre-viral-challenge state (hypergeometric-test: p=0.029). This reveals loss of AC, and supports the novel concept that not only single physiological mechanisms, but interacting dynamic disease properties are altered in asthma and contribute to a more vulnerable phenotype.
Open AccessLoss of adaptive capacity in asthmatics revealed by biomarker fluctuation dynamics upon experimental rhinovirus challenge
Asthma is a dynamic disease, in which lung mechanical and inflammatory processes often interact in a complex, unpredictable manner. We hypothesize that this may be explained by respiratory disease-related systems instability and loss of adaptability to changing environmental conditions, resulting in highly fluctuating biomarkers and symptoms. Using time series of inflammatory (eosinophils, neutrophils, FeNO), clinical and lung function biomarkers (PEF, FVC, and FEV 1 ), we estimated this loss of adaptive capacity (AC) during an experimental perturbation with a rhinovirus in 24 healthy and asthmatic volunteers. Loss of AC was estimated by comparing similarities between pre- and post-challenge time series. Unlike healthy participants, the asthmatic’s post-viral-challenge state resembled significantly more other rhinovirus-infected asthmatics than their own pre-viral-challenge state (hypergeometric-test: p=0.029). This reveals loss of AC, and supports the novel concept that not only single physiological mechanisms, but interacting dynamic disease properties are altered in asthma and contribute to a more vulnerable phenotype.