Mihail-Florin Stan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mihail-Florin Stan has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Cosmin Cobianu
Automatics, Informatics and Electrical Engineering, Valahia University of Targoviste - UVT, Targoviste, Romania
6 shared publications - Nicolae Fidel
Automatics, Informatics and Electrical Engineering, Valahia University of Targoviste - UVT, Targoviste, Romania
6 shared publications Adela-Gabriela Husu
Automatics, Informatics and Electrical Engineering, Valahia University of Targoviste - UVT, Targoviste, Romania
5 shared publicationsNicolae Fidel
Valahia University of Targoviste, Faculty of Electrical Engineering, Electronics and Information Technology, Department of Automatics, Informatics and Electrical Engineering, 130004 Targoviste, Romania
5 shared publicationsAdela Gabriela Husu
Department of Automation, Computer and Electrical Engineering, Valahia University of Targoviste, Romania
2 shared publicationsCosmin Cobianu
Valahia University of Targoviste, Faculty of Electrical Engineering, Electronics and Information Technology, Department of Automatics, Informatics and Electrical Engineering, 130004 Targoviste, Romania
2 shared publications
Latest Publications
- Open Access
- 4 August 2025
- Published by MDPI AG in Preprints.org
New Structures of Synchronous Motor with Two Stators and Single Rotor, with High-Energy NdFeB Permanent Magnets Arranged on Both Rotor Bores
The first permanent magnet electric machines appeared in the first half of the last century and their evolution was continuous as magnets with high magnetic energies appeared and magnetic circuits were created that allowed for efficient use of the magnets. The solution of the asynchronous motor with two stators with a massive rotor described in previous work opened the way to a synchronous variant of the machine with two stators, using rare earth permanent magnets, which are arranged on both cylindrical surfaces of the rotor. In this way, the volume of the magnets and the flux of the machine can be increased. The rotor construction made of solid steel, mechanically robust, does not disturb from an electromagnetic point of view, because it rotates synchronously with the fundamental of the stator field, so it will no longer induce eddy currents in the rotor iron in a permanent regime. In the synchronous variant, part of the inductor flux is closed through the rotor, which can be an advantage for the optimal use of the active surfaces of the machine.
- 4 August 2025
- Published by MDPI AG in Preprints.org
Open AccessNew Structures of Synchronous Motor with Two Stators and Single Rotor, with High-Energy NdFeB Permanent Magnets Arranged on Both Rotor Bores
The first permanent magnet electric machines appeared in the first half of the last century and their evolution was continuous as magnets with high magnetic energies appeared and magnetic circuits were created that allowed for efficient use of the magnets. The solution of the asynchronous motor with two stators with a massive rotor described in previous work opened the way to a synchronous variant of the machine with two stators, using rare earth permanent magnets, which are arranged on both cylindrical surfaces of the rotor. In this way, the volume of the magnets and the flux of the machine can be increased. The rotor construction made of solid steel, mechanically robust, does not disturb from an electromagnetic point of view, because it rotates synchronously with the fundamental of the stator field, so it will no longer induce eddy currents in the rotor iron in a permanent regime. In the synchronous variant, part of the inductor flux is closed through the rotor, which can be an advantage for the optimal use of the active surfaces of the machine.
- Open Access
- 30 December 2022
- Published by Valahia University of Targoviste - Journal of Science and Arts in Journal of Science and Arts
- Vol. 22 (4) , 965-976
ASSESSMENT OF HEAVY METALS ACCUMULATION IN WHEAT GROWN ON SEWAGE SLUDGE-TREATED FERTILE SOIL
- 30 December 2022
- Published by Valahia University of Targoviste - Journal of Science and Arts in Journal of Science and Arts
- Vol. 22 (4) , 965-976
Open AccessASSESSMENT OF HEAVY METALS ACCUMULATION IN WHEAT GROWN ON SEWAGE SLUDGE-TREATED FERTILE SOIL
- Open Access
- 1 January 2021
- Published by Valahia University of Targoviste - Journal of Science and Arts in Journal of Science and Arts
- Vol. 21 (3) , 845-856
ELECTRICAL PLATFORM FOR DRIVE OF AC ASYNCHRONOUS MOTORS AND SERVOMOTORS USING FREQUENCY CONVERTERS
- 1 January 2021
- Published by Valahia University of Targoviste - Journal of Science and Arts in Journal of Science and Arts
- Vol. 21 (3) , 845-856
Open AccessELECTRICAL PLATFORM FOR DRIVE OF AC ASYNCHRONOUS MOTORS AND SERVOMOTORS USING FREQUENCY CONVERTERS
- Open Access
- 1 January 2020
- Published by Valahia University of Targoviste - Journal of Science and Arts in Journal of Science and Arts
- Vol. 20 (4) , 1049-1060
2D NUMERICAL SIMULATION OF MAGNETIC FIELD IN LOW-VOLTAGE CIRCUIT BREAKER
Low Voltage Circuit Breakers is used for the switching process in power distribution and control system. This process is accompanied by the occurrence of the electric arc between the fixed and mobile contact pieces of the apparatus. The electric arc is introduced into the quenching chamber formed of ferromagnetic iron splitter plates, divided into short arcs and then the arc may extinguish after passing the current through zero. Behavior of the electric arc in the extinguishing chamber influences the performance of these devices, the ferromagnetic material leading to the improvement of these performances. This article presents the calculation of the magnetic field components in the extinguishing chamber of the low-voltage circuit breaker of the 2000 A, 690 V manufactured by Schneider Electric and to describe the physical phenomenon and mathematical calculation of the electric arc in LVCB. The Ansys Multiphysics program is used to determine the spectrum of magnetic field components. This program is based on the finite element method for solving Maxwell equations.
- 1 January 2020
- Published by Valahia University of Targoviste - Journal of Science and Arts in Journal of Science and Arts
- Vol. 20 (4) , 1049-1060
Open Access2D NUMERICAL SIMULATION OF MAGNETIC FIELD IN LOW-VOLTAGE CIRCUIT BREAKER
Low Voltage Circuit Breakers is used for the switching process in power distribution and control system. This process is accompanied by the occurrence of the electric arc between the fixed and mobile contact pieces of the apparatus. The electric arc is introduced into the quenching chamber formed of ferromagnetic iron splitter plates, divided into short arcs and then the arc may extinguish after passing the current through zero. Behavior of the electric arc in the extinguishing chamber influences the performance of these devices, the ferromagnetic material leading to the improvement of these performances. This article presents the calculation of the magnetic field components in the extinguishing chamber of the low-voltage circuit breaker of the 2000 A, 690 V manufactured by Schneider Electric and to describe the physical phenomenon and mathematical calculation of the electric arc in LVCB. The Ansys Multiphysics program is used to determine the spectrum of magnetic field components. This program is based on the finite element method for solving Maxwell equations.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Measuring and Maintaining the Water Level in a Tank for Efficient Use in Irrigation
This paper presents a device for measuring and maintaining the constant water level in a tank. The device uses a capacity sensor to measure the water level. The sensor has a DC voltage output proportional to the water level in the tank. This voltage can be used in other automation too. The water level, in percentages, is displayed on a vu meter with 8 LEDs. The circuit for maintaining the constant level consists in a comparator with hysteresis. The level of the water is adjustable, using a reference voltage from a potentiometer (marked in percentages). The level of the water is compared with the prescribed level and the difference between them commands the start/stop of the water pump which supplies the tank through a relay. The device is powered by 220V and is isolated from the environment.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Measuring and Maintaining the Water Level in a Tank for Efficient Use in Irrigation
This paper presents a device for measuring and maintaining the constant water level in a tank. The device uses a capacity sensor to measure the water level. The sensor has a DC voltage output proportional to the water level in the tank. This voltage can be used in other automation too. The water level, in percentages, is displayed on a vu meter with 8 LEDs. The circuit for maintaining the constant level consists in a comparator with hysteresis. The level of the water is adjustable, using a reference voltage from a potentiometer (marked in percentages). The level of the water is compared with the prescribed level and the difference between them commands the start/stop of the water pump which supplies the tank through a relay. The device is powered by 220V and is isolated from the environment.
- 1 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Position Control System for Maximum WPT Efficiency
The wireless energy transfer has been investigated over the past ten years. Therefore, technological solutions have been developed based on new discoveries in electronics from the point of view of the materials used, the various software programs for the design of systems as well as the research of the multitude of theories related to the advantages of the use of wireless energy transfer. All aspects of the implementation of this type of energy transfer in all fields of use, automotive, construction, health, environment, agriculture, education, industry have also been researched, considering the particularities of each environment as well as efficiency in terms of sustainability, autonomy of electrical systems and integration with existing technologies. In the present paper we will show a system model for controlling the position of the receiver to the transmitter in the wireless energy transfer in order to obtain the maximum efficiency.
- 1 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Position Control System for Maximum WPT Efficiency
The wireless energy transfer has been investigated over the past ten years. Therefore, technological solutions have been developed based on new discoveries in electronics from the point of view of the materials used, the various software programs for the design of systems as well as the research of the multitude of theories related to the advantages of the use of wireless energy transfer. All aspects of the implementation of this type of energy transfer in all fields of use, automotive, construction, health, environment, agriculture, education, industry have also been researched, considering the particularities of each environment as well as efficiency in terms of sustainability, autonomy of electrical systems and integration with existing technologies. In the present paper we will show a system model for controlling the position of the receiver to the transmitter in the wireless energy transfer in order to obtain the maximum efficiency.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Increasing the reliability of an industrial cold production system using Fault Tree Analysis (FTA)
Starting from the design phase of a system to its daily use, the reliability of the equipment is the most important feature of the assembly. One of the methods of defect analysis is Fault Tree Analysis (FTA). This method consists of constructing a logical schema of failure of the components of the analyzed system. In this paper we will present the analysis carried out using the FTA, at Renault - central Titu, for an artificial cold plant, a plant that serves a solar radiation simulation bench at different temperatures. This analysis was carried out after a major fault in the refrigeration plant (burning the electric motor from one of the compressors) in March 2016. The analysis was performed to define the probability of recurrence of the fault with the purpose of modifying the preventive maintenance plan and internal standardization of the verification and prevention procedure for both the facility and other similar installations.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Increasing the reliability of an industrial cold production system using Fault Tree Analysis (FTA)
Starting from the design phase of a system to its daily use, the reliability of the equipment is the most important feature of the assembly. One of the methods of defect analysis is Fault Tree Analysis (FTA). This method consists of constructing a logical schema of failure of the components of the analyzed system. In this paper we will present the analysis carried out using the FTA, at Renault - central Titu, for an artificial cold plant, a plant that serves a solar radiation simulation bench at different temperatures. This analysis was carried out after a major fault in the refrigeration plant (burning the electric motor from one of the compressors) in March 2016. The analysis was performed to define the probability of recurrence of the fault with the purpose of modifying the preventive maintenance plan and internal standardization of the verification and prevention procedure for both the facility and other similar installations.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Improvement of Wireless Power Transfer Efficiency for Home Electronics and Appliances with the Use of SMD Components
In previous applications, we have developed several technologycal solutions to present the basic principles of wireless power transfer. Following technological developments in the electronics field, we wanted to improve these applications through the use of small and high stability components. In the present paper we will present wireless energy transfer systems for a comparative analysis in order to obtain increased efficiency with low costs and dimensions. We will also present the electromagnetic field measurements as the basis for conducting a study on the effects of these systems on the environment.
- 1 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Improvement of Wireless Power Transfer Efficiency for Home Electronics and Appliances with the Use of SMD Components
In previous applications, we have developed several technologycal solutions to present the basic principles of wireless power transfer. Following technological developments in the electronics field, we wanted to improve these applications through the use of small and high stability components. In the present paper we will present wireless energy transfer systems for a comparative analysis in order to obtain increased efficiency with low costs and dimensions. We will also present the electromagnetic field measurements as the basis for conducting a study on the effects of these systems on the environment.
- 23 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Analysis of economic and energy efficiency for the grid-connected PV systems
The Pv systems development as renewable electricity sources is impressive in recent years. In different regions of the world the share of energy produced by PV systems depends on climatic factors and economical policies that require a careful analysis of energetically performances and financial investments. This study analyzes the economic and energy efficiency of a PV system connected to the network, located in three different regions from Europe. For this purpose there are used information provided by manufacturers of PV systems and databases of the Psol software package on climate parameters and technological parameters of PV systems. The results of simulations made in the 3 regions led to a comparative analysis of the economic and energy efficiency for the same PV system using a score and a ranking proposed by the authors.
- 23 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Analysis of economic and energy efficiency for the grid-connected PV systems
The Pv systems development as renewable electricity sources is impressive in recent years. In different regions of the world the share of energy produced by PV systems depends on climatic factors and economical policies that require a careful analysis of energetically performances and financial investments. This study analyzes the economic and energy efficiency of a PV system connected to the network, located in three different regions from Europe. For this purpose there are used information provided by manufacturers of PV systems and databases of the Psol software package on climate parameters and technological parameters of PV systems. The results of simulations made in the 3 regions led to a comparative analysis of the economic and energy efficiency for the same PV system using a score and a ranking proposed by the authors.
- 1 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 63, 898-902
Automatic system for monitoring of strategic infrastructure using wireless sensors
The strategic infrastructure, electrical grid, railroad, water and natural gas delivery grids are nowadays the target of choice for either terrorist or stealing activities. Monitoring the strategic infrastructure in order to prevent failures due to such activities is not an easy task due to the complexity of these systems. In this article it is presented a possible solution for monitoring the 110/400 kV electrical grid infrastructure based on the latest available electronic and IT&C components and technologies. The proposed system is designed both to provide a high level of security and to avoid false alarms and encompass a large variety of sensors and innovative techniques.
- 1 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 63, 898-902
Automatic system for monitoring of strategic infrastructure using wireless sensors
The strategic infrastructure, electrical grid, railroad, water and natural gas delivery grids are nowadays the target of choice for either terrorist or stealing activities. Monitoring the strategic infrastructure in order to prevent failures due to such activities is not an easy task due to the complexity of these systems. In this article it is presented a possible solution for monitoring the 110/400 kV electrical grid infrastructure based on the latest available electronic and IT&C components and technologies. The proposed system is designed both to provide a high level of security and to avoid false alarms and encompass a large variety of sensors and innovative techniques.