RRReza Rasooli

Reza Rasooli

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Reza Rasooli has a total of 36 co-authors. Here are the top co-authors by number of shared publications:

  • Kerem Pekkan

    Department of Mechanical Engineering, Koç University, Istanbul, Turkey

    8 shared publications
  • Aksel Hiorth

    Department of Energy Resources University of Stavanger Stavanger Norway

    4 shared publications
  • Charlotte de Lange

    Department of Pediatric Radiology, Sahlgrenska University Hospital, Gothenburg, Sweden

    3 shared publications
  • Henrik Brun

    Department of Pediatric Cardiology, Division of Pediatric and Adolescent Medicine, Oslo University Hospital, Oslo, Norway

    3 shared publications
  • Henrik Holmstrom

    Department of Pediatric Cardiology, Division of Pediatric and Adolescent Medicine, Oslo University Hospital, Oslo, Norway

    3 shared publications
  • Ingunn Westvik Jolma

    Department of Chemistry, Bioscience and Environmental Engineering, University of Stavanger, Stavanger, Norway

    3 shared publications

Latest Publications

  • Open Access

    Fluid Dynamics Measurements using Deep Learning Based Optical Flow Models

    by Kerem Pekkan, Reza Rasooli, Melis Serdar, Kağan Uçak, A. Murat Tekalp, Eda Nur Saruhan

  • Assessment of Guidewire‐Induced Deviation in Fractional Flow Reserve: Impact of Lesion Morphology and Pressure Guidewire Malposition

    by Reza Rasooli, Kerem Pekkan, Alf Inge Larsen, Aksel Hiorth

    Coronary artery disease (CAD) is one of the leading causes of mortality worldwide. Fractional flow reserve (FFR) is a diagnostic metric for evaluating ischemic coronary stenoses, necessitating invasive pressure measurements using a guidewire during maximal hyperemia. The stenosis morphology and the presence of a guidewire influence coronary hemodynamics, warranting further investigation to improve FFR accuracy. This study systematically examines the effect of a pressure guidewire on FFR across different stenosis morphologies under clinically relevant boundary conditions (BCs). Six idealized models of coronary stenosis were developed, representing area stenoses (AS: percentage reduction in the cross‐sectional area) of 64%, 75%, 84%, and 91%, based on the dimensions of the left anterior descending (LAD) artery. Computational fluid dynamics (CFD) simulations were conducted using coronary BCs validated against both in vivo and in silico data in the literature. Guidewire‐induced FFR deviation (dFFR) exhibited a linear correlation with the blockage ratio—guidewire area relative to minimum lumen area—with deviations exceeding 0.04 for AS greater than 80%. dFFR values were comparable for AS of 64% and 75% across different shapes, but shape‐related variation increased (> 0.02) at AS of 84% and 91%. Lesion length (LL) significantly influenced FFR based on morphology: a threefold increase in LL reduced FFR by 0.06 in crescent‐shaped stenosis, while having minimal impact in the fully eccentric circular case (AS 84%). However, dFFR remained largely unaffected by LL. Finally, the effects of guidewire malposition on dFFR were negligible in non‐circular stenoses (< 0.01) but considerable in circular stenoses (> 0.04 for AS 84%).


  • Open Access

    In vitro hemodynamic performance of a blood pump for self-powered venous assist in univentricular hearts

    by Reza Rasooli, Henrik Holmstrom, Knut Erik Teigen Giljarhus, Ingunn Westvik Jolma, Jan Ludvig Vinningland, Charlotte de Lange, Henrik Brun, Aksel Hiorth

    Univentricular heart anomalies represent a group of severe congenital heart defects necessitating early surgical intervention in infancy. The Fontan procedure, the final stage of single-ventricle palliation, establishes a serial connection between systemic and pulmonary circulation by channeling venous return to the lungs. The absence of the subpulmonary ventricle in this peculiar circulation progressively eventuates in failure, primarily due to chronic elevation in inferior vena cava (IVC) pressure. This study experimentally validates the effectiveness of an intracorporeally-powered venous ejector pump (VEP) in reducing IVC pressure in Fontan patients. The VEP exploits a fraction of aortic flow to create a jet-venturi effect for the IVC, negating the external power requirement and driveline infections. An invitro Fontan mock-up circulation loop is developed and the impact of VEP design parameters and physiological conditions is assessed using both idealized and patient-specific total cavopulmonary connection (TCPC) phantoms. The VEP performance in reducing IVC pressure exhibited an inverse relationship with the cardiac output and extra-cardiac conduit (ECC) size and a proportional relationship with the transpulmonary pressure gradient (TPG) and mean arterial pressure (MAP). The ideal VEP with fail-safe features provided an IVC pressure drop of 1.82 ± 0.49, 2.45 ± 0.54, and 3.12 ± 0.43 mm Hg for TPG values of 6, 8, and 10 mm Hg, respectively, averaged over all ECC sizes and cardiac outputs. Furthermore, the arterial oxygen saturation was consistently maintained above 85% during full-assist mode. These results emphasize the potential utility of the VEP to mitigate elevated venous pressure in Fontan patients.


  • Open Access

    In Vitro Hemodynamic Performance of a Blood Pump for Self-powered Venous Assist in Univentricular Hearts

    by Reza Rasooli, Henrik Holmstrom, Knut Erik Teigen Giljarhus, Ingunn Westvik Jolma, Jan Ludvig Vinningland, Charlotte de Lange, Henrik Brun, Aksel Hiorth

    Univentricular heart anomalies represent a group of severe congenital heart defects necessitating early surgical intervention in infancy. The Fontan procedure, the final stage of single-ventricle palliation, establishes a serial connection between systemic and pulmonary circulation by channeling venous return to the lungs. The absence of the subpulmonary ventricle in this peculiar circulation progressively eventuates in failure, primarily due to chronic elevation in inferior vena cava (IVC) pressure. This study experimentally validates the effectiveness of an intracorporeally-powered venous ejector pump (VEP) in reducing IVC pressure in Fontan patients. The VEP exploits a fraction of aortic flow to create a jet-venturi effect for the IVC, negating the external power requirement and driveline infections. A multi-scale in-vitro Fontan mock-up circulation loop is developed and the impact of VEP design parameters and physiological conditions is assessed using both idealized and patient-specific total cavopulmonary connection (TCPC) phantoms. The VEP performance in reducing IVC pressure exhibited an inverse relationship with the cardiac output and extra-cardiac conduit (ECC) size and a proportional relationship with the transpulmonary pressure gradient (TPG) and mean arterial pressure (MAP). The ideal VEP with fail-safe features provided an IVC pressure drop of 1.82 ± 0.49, 2.45 ± 0.54, and 3.12 ± 0.43 mm Hg for TPG values of 6, 8, and 10 mm Hg, respectively, averaged over all ECC sizes and cardiac outputs. Furthermore, the arterial oxygen saturation was consistently maintained above 85% in all conditions. These results emphasize the potential utility of the VEP to mitigate elevated venous pressure in Fontan patients.

  • Open Access

    In Silico Evaluation of a Self-powered Venous Ejector Pump for Fontan Patients

    by Reza Rasooli, Knut Erik Teigen Giljarhus, Aksel Hiorth, Ingunn Westvik Jolma, Jan Ludvig Vinningland, Charlotte de Lange, Henrik Brun, Henrik Holmstrom

    Purpose: The Fontan circulation carries a dismal prognosis in the long term due to its peculiar physiology and lack of a subpulmonic ventricle. Although it is multifactorial, elevated IVC pressure is accepted to be the primary cause of Fontan's high mortality and morbidity. This study presents a self-powered venous ejector pump (VEP) that can be used to lower the high IVC venous pressure in single-ventricle patients. Methods: A self-powered venous assist device that exploits the high-energy aortic flow to lower IVC pressure is designed. The proposed design is clinically feasible, simple in structure, and is powered intracorporeally. The device's performance in reducing IVC pressure is assessed by conducting comprehensive computational fluid dynamics simulations in idealized total cavopulmonary connections with different offsets. The device was finally applied to complex 3D reconstructed patient-specific TCPC models to validate its performance. Results: The assist device provided a significant IVC pressure drop of more than 3.2 mm Hg in both idealized and patient-specific geometries, while maintaining a high systemic oxygen saturation of more than 90%. The simulations revealed no significant caval pressure rise (< 0.1 mm Hg) and sufficient systemic oxygen saturation (> 84%) in the event of device failure, demonstrating its fail-safe feature. Conclusions: A self-powered venous assist with promising in silico performance in improving Fontan hemodynamics is proposed. Due to its passive nature, the device has the potential to provide palliation for the growing population of patients with failing Fontan.


  • Open Access

    A novel Fontan Y-graft for interrupted inferior vena cava and azygos continuation

    by S Samaneh Lashkarinia, Murat Cicek, Banu Kose, Mohammad Rezaeimoghaddam, Emine Hekim Yılmaz, Numan Ali Aydemir, Reza Rasooli, Sercin Ozkok, Nurgul Yurtseven, Hasan Erdem, et al.

    To evaluate the hemodynamicdynamic advantage of a new Fontan surgical template that is intended for complex single-ventricle patients with interrupted inferior vena cava-azygos and hemi-azygos continuation. The new technique has emerged from a comprehensive pre-surgical simulation campaign conducted to facilitate a balanced hepatic flow and somatic Fontan pathway growth after Kawashima procedure. For 9 patients, aged 2 to18 years, majority having poor preoperative oxygen saturation, a pre-surgical computational fluid dynamics customization is conducted. Both the traditional Fontan pathways and the proposed novel Y-graft templates are considered. Numerical model was validated against in vivo phase-contrast magnetic resonance imaging data and in vitro experiments. The proposed template is selected and executed for 6 out of the 9 patients based on its predicted superior hemodynamic performance. Pre-surgical simulations performed for this cohort indicated that flow from the hepatic veins (HEP) do not reach to the desired lung. The novel Y-graft template, customized via a right- or left-sided displacement of the total cavopulmonary connection anastomosis location resulted a drastic increase in HEP flow to the desired lung. Orientation of HEP to azygos direct shunt is found to be important as it can alter the flow pattern from 38% in the caudally located direct shunt to 3% in the cranial configuration with significantly reversed flow. The postoperative measurements prove that oxygen saturation increased significantly (P-value = 0.00009) to normal levels in 1 year follow-up. The new Y-graft template, if customized for the individual patient, is a viable alternative to the traditional surgical pathways. This template addresses the competing hemodynamic design factors of low physiological venous pressure, high postoperative oxygen saturation, low energy loss and balanced hepatic growth factor distribution possibly assuring adequate lung development. 25 October 2019, 280011928-604.01.01.


  • Open Access

    Hemodynamic performance limits of the neonatal Double-Lumen cannula

    by Reza Rasooli, Muhammad Jamil, Mohammad Rezaeimoghaddam, Yahya Yıldız, Ece Salihoglu, Kerem Pekkan


  • Open Access

    Estimation of pulsatile energy dissipation in intersecting pipe junctions using inflow pulsatility indices

    by Reza Rasooli, Onur Dur, Kerem Pekkan

    This study aims to characterize the effect of inflow pulsatility on the hydrodynamic power loss inside intersecting double-inlet, double-outlet pipe intersection (DIPI) with cross-flow mixing. An extensive set of computational fluid dynamics (CFD) simulations was performed in order to identify the individual effects of flow pulsatility parameters, i.e., amplitude, frequency, and relative phase shift between the inflow waveform oscillations, on power loss. An experimentally validated second order accurate solver is employed in this study. To predict the pulsatile flow performance of any given arbitrary inflow waveforms, we proposed three easy-to-calculate pulsatility indices. The frequency-coupled quasi-steady flow theory is incorporated to identify the functional form of pulsatile power loss as a function of these indices. Our results indicated that the power loss within the inflow branch sections, lumped outflow-junction section, and the whole conduit correlates strongly with the pulsatility of each inflow waveform, the total inflow pulsatility, and inflow frequency content, respectively. The complete CFD simulation matrix provided a unified analytical expression that predicts pulsatile power loss inside a one-degree offset DIPI geometry. The predictive accuracy of this expression is evaluated in comparison to the CFD evaluation of arbitrary multi-harmonic inflow waveforms. These results have important implications on hydrodynamic pipe networks that employ complex junctions as well as in the patient-to-patient comparison of surgically created vascular connections. Coupling the present analytical pulsatile power loss expression with non-dimensional steady power loss formulation provided a valuable predictive tool to estimate the pulsatile energy dissipation for any arbitrary junction geometry with minimum use of the costly CFD computations.


  • Infusion Jet Flow Control in Neonatal Double Lumen Cannulae

    by Reza Rasooli, Yahya Yıldız, Muhammad Jamil, Kerem Pekkan

    Clinical success of extracorporeal membrane oxygenation (ECMO) depends on the proper venous cannulation. Venovenous (VV) ECMO is the preferred clinical intervention as it provides a single-site access by utilizing a VV double lumen cannula (VVDLC) with a higher level of mobilization and physical rehabilitation. Concurrent venous blood drainage and oxygenated blood infusion in the right atrium at the presence of the cannula makes the flow dynamics complex where potential mixing of venous and oxygenated blood can drastically decrease the overall performance of ECMO. There are no studies focusing on the neonatal and pediatric populations, in which the flow related effects are critical due to the small atrium size. In this study, fluid dynamics of infusion outflow jet for two commercially available neonatal VVDLC is analyzed using particle image velocimetry (PIV). Moreover, six new designs are proposed for the infusion channel geometry and compared. Important flow parameters such as flow turning angle (FTA), velocity decay, potential core, and turbulent intensity are investigated for the proposed models. The experiments showed that the outflow parameters of commercial cannulae such as FTA are strongly dependent on the operating Re number. This may result in a drastic efficiency reduction for cannula operating at off-design flow conditions. Moreover, the infusion outlet tip structure and jet internal guiding pathway (JIGP) was observed to greatly affect the outflow flow features. This is of paramount importance since the anatomical positioning of the cannula and the infusion outlet is strongly dependent on the outflow properties such as FTA.