HAHafisoh Ahmad

Hafisoh Ahmad

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hafisoh Ahmad has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    GSM-based transformer oil temperature monitoring system for electrical power distribution application

    by Muhammad Sazlan Abdul Kadar, Nor Hafizah Ngajikin, Muhammad Aiman Md Haniff, Hafisoh Ahmad, Maslina Yaacob, Siti Hajar Aminah Ali, Noran Azizan Cholan

    Global mobile service (GSM)-based transformer oil temperature monitoring system for an application of electrical power distribution is developed in this work. The developed monitoring system helps to provide early notification to the maintenance worker in preventing malfunction of a transformer that is located in rural areas. The developed system consists of three main parts, which are GSM module, Arduino controller and DS18B20 electrical temperature sensor. The notification is sent through GSM text message services, whenever the transformer oil reaches hazardous temperature value which was set at 50oC. The developed system exhibits linearity of 0.9999 with 0.021 mV/oC sensitivity. The monitoring system has potential to be adopted in many other applications that require low temperature real-time monitoring system.


  • Open Access

    The Electrical Performance of Microvaristor Composites at Different Filler Loadings

    by H. Ahmad, H.A. Ismail, A. Haddad

    Resistive field grading materials is deliberately gaining attention since it shows better performance in steering uniformly electrical properties of high voltage equipment compared to conventional machinery techniques. The key point of these extraordinary materials because its electrical properties that can be tuneable according to material characteristics, composition of chemical elements in the host matrix and significantly influenced from fabrication process. In this research, microvaristor composite was added with silicone rubber at different weight percentage (wt. %) with dimension 50 mm x 50 mm x 5 mm. The selection of this material because it is more robust and less sensitive to a variety parameters such as pressure and humidity. The samples were examined under power frequency voltage at 50 Hz. The experimental results were analysed using Point on Wave (POW) technique and electrical properties for all samples were evaluated at highest applied voltage, 5 kV.

  • Open Access

    Higher Order Feature Extraction and Selection for Robust Human Gesture Recognition using CSI of COTS Wi-Fi Devices

    by Hasmath Farhana Thariq Ahmed, Hafisoh Ahmad, Swee King Phang, Chockalingam Aravind Vaithilingam, Houda Harkat, Kulasekharan Narasingamurthi

    Device-free human gesture recognition (HGR) using commercial off the shelf (COTS) Wi-Fi devices has gained attention with recent advances in wireless technology. HGR recognizes the human activity performed, by capturing the reflections of Wi-Fi signals from moving humans and storing them as raw channel state information (CSI) traces. Existing work on HGR applies noise reduction and transformation to pre-process the raw CSI traces. However, these methods fail to capture the non-Gaussian information in the raw CSI data due to its limitation to deal with linear signal representation alone. The proposed higher order statistics-based recognition (HOS-Re) model extracts higher order statistical (HOS) features from raw CSI traces and selects a robust feature subset for the recognition task. HOS-Re addresses the limitations in the existing methods, by extracting third order cumulant features that maximizes the recognition accuracy. Subsequently, feature selection methods derived from information theory construct a robust and highly informative feature subset, fed as input to the multilevel support vector machine (SVM) classifier in order to measure the performance. The proposed methodology is validated using a public database SignFi, consisting of 276 gestures with 8280 gesture instances, out of which 5520 are from the laboratory and 2760 from the home environment using a 10 × 5 cross-validation. HOS-Re achieved an average recognition accuracy of 97.84%, 98.26% and 96.34% for the lab, home and lab + home environment respectively. The average recognition accuracy for 150 sign gestures with 7500 instances, collected from five different users was 96.23% in the laboratory environment.