Richard M. England
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Richard M. England has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
Marianne B. Ashford
Advanced Drug Delivery, Pharmaceutical Sciences, R&D
6 shared publications- Perdita Elizabeth Barran
University of Manchester
4 shared publications Anders Gunnarsson
Discovery Sciences, R&D
3 shared publicationsJennifer I. Moss
Bioscience, Discovery, Oncology R&D, AstraZeneca, Cambridge CB2 0AA, U.K.
3 shared publications- Kevin Treacher
AstraZeneca
3 shared publications - Marianne Ashford
Advanced Drug Delivery, Pharmaceutical Sciences, R&D, AstraZeneca, Macclesfield, UK
3 shared publications
Latest Publications
- 19 November 2025
- Published by American Chemical Society (ACS) in Biomacromolecules
- Vol. 26 (12) , 8752-8762
Effect of Corona Block Structure on Telodendrimer Micelles: Probing Exchange Kinetics by Fluorescence Spectroscopy
Telodendrimer micelles with low critical micelle concentrations (CMCs) were synthesized using a hydrophilic poly(sarcosine) (PSar) block and a lysine-based dendritic block carrying four stably conjugated Vadimezan. Variations in the hydrophilic block architecture were made to determine the impact on micelle stability, including variable chain length (n = 50 or 100) and a branched, two-arm structure (n = 50/arm). Despite determining similar CMC (0.8-2.2 μM) values for the micelles, fluorescence resonance energy transfer (FRET) revealed kinetic stability differences. The micelle with the shortest PSar chain showed the fastest unimer exchange kinetics, while longer PSar and branched PSar micelles had similar, overall better stability. Slower unimer re-entry was observed for larger, sterically hindered unimers. The study suggests that hydrophilic block size and topology are equally important in the design criteria as the hydrophobic portion for stability and CMC alone is insufficient to predict micelle behavior in complex biological media.
- 19 November 2025
- Published by American Chemical Society (ACS) in Biomacromolecules
- Vol. 26 (12) , 8752-8762
Effect of Corona Block Structure on Telodendrimer Micelles: Probing Exchange Kinetics by Fluorescence Spectroscopy
Telodendrimer micelles with low critical micelle concentrations (CMCs) were synthesized using a hydrophilic poly(sarcosine) (PSar) block and a lysine-based dendritic block carrying four stably conjugated Vadimezan. Variations in the hydrophilic block architecture were made to determine the impact on micelle stability, including variable chain length (n = 50 or 100) and a branched, two-arm structure (n = 50/arm). Despite determining similar CMC (0.8-2.2 μM) values for the micelles, fluorescence resonance energy transfer (FRET) revealed kinetic stability differences. The micelle with the shortest PSar chain showed the fastest unimer exchange kinetics, while longer PSar and branched PSar micelles had similar, overall better stability. Slower unimer re-entry was observed for larger, sterically hindered unimers. The study suggests that hydrophilic block size and topology are equally important in the design criteria as the hydrophobic portion for stability and CMC alone is insufficient to predict micelle behavior in complex biological media.
- Open Access
- 6 May 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-13
Conformational landscapes of rigid and flexible molecules explored with variable temperature ion mobility-mass spectrometry
Understanding the effect of temperature to the structural integrity of proteins is relevant to diverse areas such as biotechnology and climate change. Variable temperature ion mobility-mass spectrometry (VT-IM-MS) can measure the effect of temperature on conformational landscapes. To delineate collision effects from structural change we report measurements using molecules with different degrees of rigidity namely: poly (L-lysine) (PLL) dendrimer, ubiquitin, β-casein and α-synuclein from 190-350 K. The CCS of PLL dendrimer varies with temperature consistent with collision theory, by contrast, the structure of each protein alters with notable restructuring at 350 K and 250 K, following predicted in vitro stability curves. At 210 K and 190 K we kinetically trap unfolding intermediates. For alpha-synuclein, the 13+ ions present two distinct conformers and VT-IM-MS measurements allow us to calculate the transition rate and activation energies of their conversion. These data exemplify the capacity of VT-IM-MS to provide insights on the thermodynamics of conformational restructuring.
- 6 May 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-13
Open AccessConformational landscapes of rigid and flexible molecules explored with variable temperature ion mobility-mass spectrometry
Understanding the effect of temperature to the structural integrity of proteins is relevant to diverse areas such as biotechnology and climate change. Variable temperature ion mobility-mass spectrometry (VT-IM-MS) can measure the effect of temperature on conformational landscapes. To delineate collision effects from structural change we report measurements using molecules with different degrees of rigidity namely: poly (L-lysine) (PLL) dendrimer, ubiquitin, β-casein and α-synuclein from 190-350 K. The CCS of PLL dendrimer varies with temperature consistent with collision theory, by contrast, the structure of each protein alters with notable restructuring at 350 K and 250 K, following predicted in vitro stability curves. At 210 K and 190 K we kinetically trap unfolding intermediates. For alpha-synuclein, the 13+ ions present two distinct conformers and VT-IM-MS measurements allow us to calculate the transition rate and activation energies of their conversion. These data exemplify the capacity of VT-IM-MS to provide insights on the thermodynamics of conformational restructuring.
- Open Access
- 30 May 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (23) , 9390-9398
Exploring the Conformational Landscape of Poly(l-lysine) Dendrimers Using Ion Mobility Mass Spectrometry
Ion mobility mass spectrometry (IM-MS) measures the mass, size, and shape of ions in the same experiment, and structural information is provided via collision cross-section (CCS) values. The majority of commercially available IM-MS instrumentation relies on the use of CCS calibrants, and here, we present data from a family of poly(l-lysine) dendrimers and explore their suitability for this purpose. In order to test these compounds, we employed three different IM-MS platforms (Agilent 6560 IM-QToF, Waters Synapt G2, and a home-built variable temperature drift tube IM-MS) and used them to investigate six different generations of dendrimers in two buffer gases (helium and nitrogen). Each molecule gives a highly discrete CCS distribution suggestive of single conformers for each m/z value. The DTCCSN2 values of this series of molecules (molecular weight: 330-16,214 Da) range from 182 to 2941 & Aring;2, which spans the CCS range that would be found by many synthetic molecules including supramolecular compounds and many biopolymers. The CCS values for each charge state were highly reproducible in day-to-day analysis on each instrument, although we found small variations in the absolute CCS values between instruments. The rigidity of each dendrimer was probed using collisionally activated and high-temperature IM-MS experiments, where no evidence for a significant CCS change ensued. Taken together, this data indicates that these polymers are candidates for CCS calibration and could also help to reconcile differences found in CCS measurements on different instrument geometries.
- 30 May 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (23) , 9390-9398
Open AccessExploring the Conformational Landscape of Poly(l-lysine) Dendrimers Using Ion Mobility Mass Spectrometry
Ion mobility mass spectrometry (IM-MS) measures the mass, size, and shape of ions in the same experiment, and structural information is provided via collision cross-section (CCS) values. The majority of commercially available IM-MS instrumentation relies on the use of CCS calibrants, and here, we present data from a family of poly(l-lysine) dendrimers and explore their suitability for this purpose. In order to test these compounds, we employed three different IM-MS platforms (Agilent 6560 IM-QToF, Waters Synapt G2, and a home-built variable temperature drift tube IM-MS) and used them to investigate six different generations of dendrimers in two buffer gases (helium and nitrogen). Each molecule gives a highly discrete CCS distribution suggestive of single conformers for each m/z value. The DTCCSN2 values of this series of molecules (molecular weight: 330-16,214 Da) range from 182 to 2941 & Aring;2, which spans the CCS range that would be found by many synthetic molecules including supramolecular compounds and many biopolymers. The CCS values for each charge state were highly reproducible in day-to-day analysis on each instrument, although we found small variations in the absolute CCS values between instruments. The rigidity of each dendrimer was probed using collisionally activated and high-temperature IM-MS experiments, where no evidence for a significant CCS change ensued. Taken together, this data indicates that these polymers are candidates for CCS calibration and could also help to reconcile differences found in CCS measurements on different instrument geometries.
- 27 February 2024
- Published by Royal Society of Chemistry (RSC) in Polymer Chemistry
- Vol. 15 (13) , 1318-1330
Enhanced rate of sarcosine N-carboxyanhydride polymerisation from a lysine dendrimer macroinitiator driven by neighbouring H-bonding effects
In situ FTIR monitoring revealed that sarcosine N-carboxyanhydride polymerisations were catalysed using a lysine dendrimer macroinitiator owing to hydrogen bonding interactions between the dendrimer core and monomer.
- 27 February 2024
- Published by Royal Society of Chemistry (RSC) in Polymer Chemistry
- Vol. 15 (13) , 1318-1330
Enhanced rate of sarcosine N-carboxyanhydride polymerisation from a lysine dendrimer macroinitiator driven by neighbouring H-bonding effects
In situ FTIR monitoring revealed that sarcosine N-carboxyanhydride polymerisations were catalysed using a lysine dendrimer macroinitiator owing to hydrogen bonding interactions between the dendrimer core and monomer.
- Open Access
- 7 February 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Conformational landscapes of rigid and flexible molecules explored with variable temperature ion mobility-mass spectrometry
Understanding the effect of temperature to the structural integrity and dynamics of proteins has relevance for many areas including biotechnology and the maintenance of a stable food supply for the climate emergency. The methods that can explore changes in structure as a function of sub-ambient temperature are scant, and yet many drugs are stored at such temperatures. Here we show how variable temperature ion mobility-mass spectrometry (VT-IM-MS) can provide the role of temperature on conformational landscapes in the form of collision cross sections at discrete temperatures. To delineate collision effects from structural change we report measurements made on four molecules that possess different degrees of rigidity namely: poly (L-lysine) (PLL) dendrimer, ubiquitin, β-casein and α-synuclein from 190-350K. We show that the PLL dendrimer varies with temperature consistent with collision theory, and conclude, as expected, its structure does not alter significantly over this range. By contrast, the structure of each protein is altered by the temperature of the drift gas, with notable unfolding to all charge states at 350 K and also at 250 K, following predicted in vitro stability curves, and with conformational variation that gives qualitative insights to the effect of temperature on the free energy landscape of these proteins. We also show that we can kinetically trap unfolding intermediates at drift temperatures of 210 K and 190 K on a millisecond experimental time scale. For alpha-synuclein, the 13+ ions present two distinct conformers and VT-IM-MS measurements allow us to calculate the transition rate and activation energies for conversion between these. These data exemplify the capability of VT-IM-MS to provide insights to thermodynamics involved in conformational restructuring.
- 7 February 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessConformational landscapes of rigid and flexible molecules explored with variable temperature ion mobility-mass spectrometry
Understanding the effect of temperature to the structural integrity and dynamics of proteins has relevance for many areas including biotechnology and the maintenance of a stable food supply for the climate emergency. The methods that can explore changes in structure as a function of sub-ambient temperature are scant, and yet many drugs are stored at such temperatures. Here we show how variable temperature ion mobility-mass spectrometry (VT-IM-MS) can provide the role of temperature on conformational landscapes in the form of collision cross sections at discrete temperatures. To delineate collision effects from structural change we report measurements made on four molecules that possess different degrees of rigidity namely: poly (L-lysine) (PLL) dendrimer, ubiquitin, β-casein and α-synuclein from 190-350K. We show that the PLL dendrimer varies with temperature consistent with collision theory, and conclude, as expected, its structure does not alter significantly over this range. By contrast, the structure of each protein is altered by the temperature of the drift gas, with notable unfolding to all charge states at 350 K and also at 250 K, following predicted in vitro stability curves, and with conformational variation that gives qualitative insights to the effect of temperature on the free energy landscape of these proteins. We also show that we can kinetically trap unfolding intermediates at drift temperatures of 210 K and 190 K on a millisecond experimental time scale. For alpha-synuclein, the 13+ ions present two distinct conformers and VT-IM-MS measurements allow us to calculate the transition rate and activation energies for conversion between these. These data exemplify the capability of VT-IM-MS to provide insights to thermodynamics involved in conformational restructuring.
- Open Access
- 20 December 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Exploring the Conformational Landscape of Poly(L-lysine) Dendrimers using Ion Mobility Mass Spectrometry
Ion mobility mass spectrometry (IM-MS) measures the mass, size and shape of ions in the same experiment, and structural information are provided via collision cross section (CCS) values. The majority of commercially available IM-MS instrumentation relies on the use of CCS calibrants, and here we present data from a family of poly(L-lysine) dendrimers and explore their suitability for this purpose. In order to test these compounds we employed three different IM-MS platforms (Agilent 6560 IM-QToF, Waters Synapt G2 and a home-built variable temperature drift-tube IM-MS) and used them to investigate six different generations of dendrimers in two buffer gases (helium and nitrogen). Each molecule gives a highly discrete CCS distribution suggestive of single conformers for each m/z value. The DTCCSN2 values of this series of molecules (molecular weight: 330 - 16214 Da) range from 180 to 2940 Å2, which spans the CCS range that would be found by many synthetic molecules including supramolecular compounds as well as many biopolymers. The CCS values for each charge state were highly reproducible in day to day analysis on each instrument although we find some small systematic variations between instruments. The rigidity of each dendrimer was probed using collisionally activated as well as high-temperature IM-MS experiments, where no evidence for significant CCS change ensued. Taken together, this data indicates that these polymers are candidates for CCS calibration and could also help to reconcile differences found in CCS measurements on different instrument geometries.
- 20 December 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessExploring the Conformational Landscape of Poly(L-lysine) Dendrimers using Ion Mobility Mass Spectrometry
Ion mobility mass spectrometry (IM-MS) measures the mass, size and shape of ions in the same experiment, and structural information are provided via collision cross section (CCS) values. The majority of commercially available IM-MS instrumentation relies on the use of CCS calibrants, and here we present data from a family of poly(L-lysine) dendrimers and explore their suitability for this purpose. In order to test these compounds we employed three different IM-MS platforms (Agilent 6560 IM-QToF, Waters Synapt G2 and a home-built variable temperature drift-tube IM-MS) and used them to investigate six different generations of dendrimers in two buffer gases (helium and nitrogen). Each molecule gives a highly discrete CCS distribution suggestive of single conformers for each m/z value. The DTCCSN2 values of this series of molecules (molecular weight: 330 - 16214 Da) range from 180 to 2940 Å2, which spans the CCS range that would be found by many synthetic molecules including supramolecular compounds as well as many biopolymers. The CCS values for each charge state were highly reproducible in day to day analysis on each instrument although we find some small systematic variations between instruments. The rigidity of each dendrimer was probed using collisionally activated as well as high-temperature IM-MS experiments, where no evidence for significant CCS change ensued. Taken together, this data indicates that these polymers are candidates for CCS calibration and could also help to reconcile differences found in CCS measurements on different instrument geometries.
- 17 March 2023
- Published by Elsevier in Journal of Controlled Release
- Vol. 356, 580-594
Precise and systematic end group chemistry modifications on PAMAM and poly(l-lysine) dendrimers to improve cytosolic delivery of mRNA
- 17 March 2023
- Published by Elsevier in Journal of Controlled Release
- Vol. 356, 580-594
Precise and systematic end group chemistry modifications on PAMAM and poly(l-lysine) dendrimers to improve cytosolic delivery of mRNA
- 6 April 2022
- Published by Royal Society of Chemistry (RSC) in Polymer Chemistry
- Vol. 13 (18) , 2626-2636
Investigating the properties of l-lysine dendrimers through physico-chemical characterisation techniques and atomistic molecular dynamics simulations
Poly(l-lysine) dendrimers up to generation 6 have been analysed by SEC, Taylor dispersion analysis and atomistic molecular dynamics simulations to determine their properties, in what could be considered an understudied dendrimer series.
- 6 April 2022
- Published by Royal Society of Chemistry (RSC) in Polymer Chemistry
- Vol. 13 (18) , 2626-2636
Investigating the properties of l-lysine dendrimers through physico-chemical characterisation techniques and atomistic molecular dynamics simulations
Poly(l-lysine) dendrimers up to generation 6 have been analysed by SEC, Taylor dispersion analysis and atomistic molecular dynamics simulations to determine their properties, in what could be considered an understudied dendrimer series.
- 7 January 2022
- Published by American Chemical Society (ACS) in Macromolecules
- Vol. 55 (2) , 401-412
Designing Highly Stable Poly(sarcosine)-Based Telodendrimer Micelles with High Drug Content Exemplified with Fulvestrant
- 7 January 2022
- Published by American Chemical Society (ACS) in Macromolecules
- Vol. 55 (2) , 401-412
Designing Highly Stable Poly(sarcosine)-Based Telodendrimer Micelles with High Drug Content Exemplified with Fulvestrant
- 19 February 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (8) , 3742-3749
Method to Investigate the Distribution of Water-Soluble Drug-Delivery Systems in Fresh Frozen Tissues Using Imaging Mass Cytometry
Imaging mass cytometry (IMC) offers the opportunity to image metal- and heavy halogen-containing xenobiotics in a highly multiplexed experiment with other immunochemistry-based reagents to distinguish uptake into different tissue structures or cell types. However, in practice, many xenobiotics are not amenable to this analysis, as any compound which is not bound to the tissue matrix will delocalize during aqueous sample-processing steps required for IMC analysis. Here, we present a strategy to perform IMC experiments on a water-soluble polysarcosine-modified dendrimer drug-delivery system (S-Dends). This strategy involves two consecutive imaging acquisitions on the same tissue section using the same instrumental platform, an initial laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MSI) experiment followed by tissue staining and a standard IMC experiment. We demonstrated that settings can be found for the initial ablation step that leave sufficient residual tissue for subsequent antibody staining and visualization. This workflow results in lateral resolution for the S-Dends of 2 μm followed by imaging of metal-tagged antibodies at 1 μm.
- 19 February 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (8) , 3742-3749
Method to Investigate the Distribution of Water-Soluble Drug-Delivery Systems in Fresh Frozen Tissues Using Imaging Mass Cytometry
Imaging mass cytometry (IMC) offers the opportunity to image metal- and heavy halogen-containing xenobiotics in a highly multiplexed experiment with other immunochemistry-based reagents to distinguish uptake into different tissue structures or cell types. However, in practice, many xenobiotics are not amenable to this analysis, as any compound which is not bound to the tissue matrix will delocalize during aqueous sample-processing steps required for IMC analysis. Here, we present a strategy to perform IMC experiments on a water-soluble polysarcosine-modified dendrimer drug-delivery system (S-Dends). This strategy involves two consecutive imaging acquisitions on the same tissue section using the same instrumental platform, an initial laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MSI) experiment followed by tissue staining and a standard IMC experiment. We demonstrated that settings can be found for the initial ablation step that leave sufficient residual tissue for subsequent antibody staining and visualization. This workflow results in lateral resolution for the S-Dends of 2 μm followed by imaging of metal-tagged antibodies at 1 μm.