Mallika Bariya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mallika Bariya has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Ali Javey
Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, CA, USA
9 shared publications - Hnin Yin Yin Nyein
Department of Chemical and Biological Engineering, The Hong Kong University of Science and Technology, Clear Water Bay, Hong Kong SAR, China
6 shared publications Li-Chia Tai
Department of Electrical Engineering and Computer Sciences
4 shared publications- Wenbo Ji
Department of Electrical Engineering and Computer Sciences, University of California, Berkeley, California 94720, United States
4 shared publications Jiangqi Zhao
Materials Sciences Division , Lawrence Berkeley National Laboratory , Berkeley , California 94720 , United States
3 shared publications- Li-Chia Tai
Department of Electrical and Computer Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan
3 shared publications
Latest Publications
- 12 April 2022
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 7 (4) , 1156-1164
Resettable Microfluidics for Broad-Range and Prolonged Sweat Rate Sensing
Wearable sweat sensors are emerging as promising platforms for personalized and real-time tracking of evolving health and fitness parameters. While most wearable sweat sensors focus on tracking biomarker concentration profiles, sweat secretion rate is a key metric with broad implications for assessing hydration, cardiac, and neural conditions. Here we present a wearable microfluidic sensor for continuous sweat rate measurement. A discrete impedimetric sensing scheme relying on interdigitated electrodes within a microfluidic sweat collector allows for precise and selective sweat rate measurement across a broad physiological range. Integration of a manually activated pressure pump to expel sweat from the device prevents sensor saturation and enables continuous sweat rate tracking over hours. By enabling broad range and prolonged sweat rate measurement, this platform tackles a key obstacle to realizing meaningful and actionable sweat sensing for applications in exercise physiology and medicine.
- 12 April 2022
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 7 (4) , 1156-1164
Resettable Microfluidics for Broad-Range and Prolonged Sweat Rate Sensing
Wearable sweat sensors are emerging as promising platforms for personalized and real-time tracking of evolving health and fitness parameters. While most wearable sweat sensors focus on tracking biomarker concentration profiles, sweat secretion rate is a key metric with broad implications for assessing hydration, cardiac, and neural conditions. Here we present a wearable microfluidic sensor for continuous sweat rate measurement. A discrete impedimetric sensing scheme relying on interdigitated electrodes within a microfluidic sweat collector allows for precise and selective sweat rate measurement across a broad physiological range. Integration of a manually activated pressure pump to expel sweat from the device prevents sensor saturation and enables continuous sweat rate tracking over hours. By enabling broad range and prolonged sweat rate measurement, this platform tackles a key obstacle to realizing meaningful and actionable sweat sensing for applications in exercise physiology and medicine.
- Open Access
- 28 August 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 6 (35) , eabb8308
Glove-based sensors for multimodal monitoring of natural sweat
Functionalized glove sensors allow natural sweat analysis without requiring exercise or iontophoretic stimulation.
- 28 August 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 6 (35) , eabb8308
Open AccessGlove-based sensors for multimodal monitoring of natural sweat
Functionalized glove sensors allow natural sweat analysis without requiring exercise or iontophoretic stimulation.
- 19 May 2020
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 5 (6) , 1831-1837
Nicotine Monitoring with a Wearable Sweat Band
The tobacco epidemic is a public health threat that has taken a heavy toll of lives around the globe each year. Smoking affects both the smokers and those who are exposed to secondhand smoke, and careful tracking of exposure can be key to mitigating the potential hazards. For smokers, the variation of chemical compositions between commercial cigarettes has led to ambiguity in estimating the health risks, both for active smokers and others involuntarily exposed to tobacco smoke and byproducts. In this regard, sweat possesses an attractive opportunity to monitor smoke exposure due to sweat’s abundance in biomolecules and its great accessibility. Here we present a wearable sweat band to monitor nicotine, a prominent ingredient in cigarettes, as a viable way to quantitatively assess a wearer’s exposure to smoking. Both smokers and normal subjects are tested to demonstrate the use of this device for smoke-related health monitoring. Our results exhibit confirmable, elevated nicotine levels in sweat for subjects inhaling cigarette smoke. This continuous, personalized sweat sensing device is a leverage to monitor smoke pollution for a potentially broad population.
- 19 May 2020
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 5 (6) , 1831-1837
Nicotine Monitoring with a Wearable Sweat Band
The tobacco epidemic is a public health threat that has taken a heavy toll of lives around the globe each year. Smoking affects both the smokers and those who are exposed to secondhand smoke, and careful tracking of exposure can be key to mitigating the potential hazards. For smokers, the variation of chemical compositions between commercial cigarettes has led to ambiguity in estimating the health risks, both for active smokers and others involuntarily exposed to tobacco smoke and byproducts. In this regard, sweat possesses an attractive opportunity to monitor smoke exposure due to sweat’s abundance in biomolecules and its great accessibility. Here we present a wearable sweat band to monitor nicotine, a prominent ingredient in cigarettes, as a viable way to quantitatively assess a wearer’s exposure to smoking. Both smokers and normal subjects are tested to demonstrate the use of this device for smoke-related health monitoring. Our results exhibit confirmable, elevated nicotine levels in sweat for subjects inhaling cigarette smoke. This continuous, personalized sweat sensing device is a leverage to monitor smoke pollution for a potentially broad population.
- 13 April 2020
- Published by Wiley in Advanced Materials
- Vol. 32 (21) , e1908385
Trace‐Level, Multi‐Gas Detection for Food Quality Assessment Based on Decorated Silicon Transistor Arrays
Multiplexed gas detection at room temperature is critical for practical applications, such as for tracking the complex chemical environments associated with food decomposition and spoilage. An integrated array of multiple silicon‐based, chemical‐sensitive field effect transistors (CSFETs) is presented to realize selective, sensitive, and simultaneous measurement of gases typically associated with food spoilage. CSFETs decorated with sensing materials based on ruthenium, silver, and silicon oxide are used to obtain stable room‐temperature responses to ammonia (NH3), hydrogen sulfide (H2S), and humidity, respectively. For example, one multi‐CSFET sensor signal changes from its baseline by 13.34 in response to 1 ppm of NH3, 724.45 under 1 ppm H2S, and 23.46 under 80% relative humidity, with sensitive detection down to 10 ppb of NH3 and H2S. To demonstrate this sensor for practical applications, the CSFET sensor array is combined with a custom‐printed circuit board into a compact, fully integrated, and portable system to conduct real‐time monitoring of gases generated by decomposing food. By using existing silicon‐based manufacturing methodologies, this room‐temperature gas sensing array can be fabricated reproducibly and at low cost, making it an attractive platform for ambient gas measurement needed in food safety applications.
- 13 April 2020
- Published by Wiley in Advanced Materials
- Vol. 32 (21) , e1908385
Trace‐Level, Multi‐Gas Detection for Food Quality Assessment Based on Decorated Silicon Transistor Arrays
Multiplexed gas detection at room temperature is critical for practical applications, such as for tracking the complex chemical environments associated with food decomposition and spoilage. An integrated array of multiple silicon‐based, chemical‐sensitive field effect transistors (CSFETs) is presented to realize selective, sensitive, and simultaneous measurement of gases typically associated with food spoilage. CSFETs decorated with sensing materials based on ruthenium, silver, and silicon oxide are used to obtain stable room‐temperature responses to ammonia (NH3), hydrogen sulfide (H2S), and humidity, respectively. For example, one multi‐CSFET sensor signal changes from its baseline by 13.34 in response to 1 ppm of NH3, 724.45 under 1 ppm H2S, and 23.46 under 80% relative humidity, with sensitive detection down to 10 ppb of NH3 and H2S. To demonstrate this sensor for practical applications, the CSFET sensor array is combined with a custom‐printed circuit board into a compact, fully integrated, and portable system to conduct real‐time monitoring of gases generated by decomposing food. By using existing silicon‐based manufacturing methodologies, this room‐temperature gas sensing array can be fabricated reproducibly and at low cost, making it an attractive platform for ambient gas measurement needed in food safety applications.
- 19 August 2019
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 19 (19) , 3179-3189
A multi-modal sweat sensing patch for cross-verification of sweat rate, total ionic charge, and Na + concentration
Sweat sensors introduced in recent years have targeted a variety of sweat features and biomarkers for non-invasive health monitoring. Amongst these targets, reliable monitoring of sweat rate is crucial due to its modulation of sweat analyte concentrations and its intrinsic significance to numerous medical and physiological health conditions. Here we present a sweat rate sensor structure comprising of electrodes with interdigitated fingers in a microfluidic channel. Each time the accumulating sweat impinges on an electrode finger, the sensor reports a jump in admittance that can be simply and efficiently counted to estimate sweat rate, overcoming selectivity limitations of previously reported sweat rate sensors. We further integrate an impedimetric sensor for measuring total ionic charge concentration and an electrochemical Na+ sensor, together creating a multi-modal system for analyzing fluid and electrolyte secretion. We demonstrate how low analyte diffusion rates through this microfluidic device allow for multi-purpose sensor function, including utilizing the sweat rate sensor signal to corroborate total ionic sensor measurements. This cross-verification capability ensures data integrity in real time, satisfying a vital consideration for personalized healthcare technologies. We use the presented patch for continuous analysis of sweat rate, total ionic charge concentration, and Na+ concentration during exercise, while demonstrating how multi-modal cross-verification brings new trust to sensor readings.
- 19 August 2019
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 19 (19) , 3179-3189
A multi-modal sweat sensing patch for cross-verification of sweat rate, total ionic charge, and Na + concentration
Sweat sensors introduced in recent years have targeted a variety of sweat features and biomarkers for non-invasive health monitoring. Amongst these targets, reliable monitoring of sweat rate is crucial due to its modulation of sweat analyte concentrations and its intrinsic significance to numerous medical and physiological health conditions. Here we present a sweat rate sensor structure comprising of electrodes with interdigitated fingers in a microfluidic channel. Each time the accumulating sweat impinges on an electrode finger, the sensor reports a jump in admittance that can be simply and efficiently counted to estimate sweat rate, overcoming selectivity limitations of previously reported sweat rate sensors. We further integrate an impedimetric sensor for measuring total ionic charge concentration and an electrochemical Na+ sensor, together creating a multi-modal system for analyzing fluid and electrolyte secretion. We demonstrate how low analyte diffusion rates through this microfluidic device allow for multi-purpose sensor function, including utilizing the sweat rate sensor signal to corroborate total ionic sensor measurements. This cross-verification capability ensures data integrity in real time, satisfying a vital consideration for personalized healthcare technologies. We use the presented patch for continuous analysis of sweat rate, total ionic charge concentration, and Na+ concentration during exercise, while demonstrating how multi-modal cross-verification brings new trust to sensor readings.
- 5 August 2019
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 19 (9) , 6346-6351
Wearable Sweat Band for Noninvasive Levodopa Monitoring
Levodopa is the standard medication clinically prescribed to patients afflicted with Parkinson’s disease. In particular, the monitoring and optimization of levodopa dosage are critical to mitigate the onset of undesired fluctuations in the patients’ physical and emotional conditions such as speech function, motor behavior, and mood stability. The traditional approach to optimize levodopa dosage involves evaluating the subjects’ motor function, which has many shortcomings due to its subjective and limited quantifiable nature. Here, we present a wearable sweat band on a nanodendritic platform that quantitatively monitors levodopa dynamics in the body. Both stationary iontophoretic induction and physical exercise are utilized as our methods of sweat extraction. The sweat band measures real-time pharmacokinetic profiles of levodopa to track the dynamic response of the drug metabolism. We demonstrated the sweat band’s functionalities on multiple subjects with implications toward the systematic administering of levodopa and routine management of Parkinson’s disease.
- 5 August 2019
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 19 (9) , 6346-6351
Wearable Sweat Band for Noninvasive Levodopa Monitoring
Levodopa is the standard medication clinically prescribed to patients afflicted with Parkinson’s disease. In particular, the monitoring and optimization of levodopa dosage are critical to mitigate the onset of undesired fluctuations in the patients’ physical and emotional conditions such as speech function, motor behavior, and mood stability. The traditional approach to optimize levodopa dosage involves evaluating the subjects’ motor function, which has many shortcomings due to its subjective and limited quantifiable nature. Here, we present a wearable sweat band on a nanodendritic platform that quantitatively monitors levodopa dynamics in the body. Both stationary iontophoretic induction and physical exercise are utilized as our methods of sweat extraction. The sweat band measures real-time pharmacokinetic profiles of levodopa to track the dynamic response of the drug metabolism. We demonstrated the sweat band’s functionalities on multiple subjects with implications toward the systematic administering of levodopa and routine management of Parkinson’s disease.
- Top Cited PapersOpen Access
- 2 August 2019
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 5 (8) , eaaw9906
Regional and correlative sweat analysis using high-throughput microfluidic sensing patches toward decoding sweat
Recent technological advancements in wearable sensors have made it easier to detect sweat components, but our limited understanding of sweat restricts its application. A critical bottleneck for temporal and regional sweat analysis is achieving uniform, high-throughput fabrication of sweat sensor components, including microfluidic chip and sensing electrodes. To overcome this challenge, we introduce microfluidic sensing patches mass fabricated via roll-to-roll (R2R) processes. The patch allows sweat capture within a spiral microfluidic for real-time measurement of sweat parameters including [Na+], [K+], [glucose], and sweat rate in exercise and chemically induced sweat. The patch is demonstrated for investigating regional sweat composition, predicting whole-body fluid/electrolyte loss during exercise, uncovering relationships between sweat metrics, and tracking glucose dynamics to explore sweat-to-blood correlations in healthy and diabetic individuals. By enabling a comprehensive sweat analysis, the presented device is a crucial tool for advancing sweat testing beyond the research stage for point-of-care medical and athletic applications.
- 2 August 2019
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 5 (8) , eaaw9906
Top Cited PapersOpen AccessRegional and correlative sweat analysis using high-throughput microfluidic sensing patches toward decoding sweat
Recent technological advancements in wearable sensors have made it easier to detect sweat components, but our limited understanding of sweat restricts its application. A critical bottleneck for temporal and regional sweat analysis is achieving uniform, high-throughput fabrication of sweat sensor components, including microfluidic chip and sensing electrodes. To overcome this challenge, we introduce microfluidic sensing patches mass fabricated via roll-to-roll (R2R) processes. The patch allows sweat capture within a spiral microfluidic for real-time measurement of sweat parameters including [Na+], [K+], [glucose], and sweat rate in exercise and chemically induced sweat. The patch is demonstrated for investigating regional sweat composition, predicting whole-body fluid/electrolyte loss during exercise, uncovering relationships between sweat metrics, and tracking glucose dynamics to explore sweat-to-blood correlations in healthy and diabetic individuals. By enabling a comprehensive sweat analysis, the presented device is a crucial tool for advancing sweat testing beyond the research stage for point-of-care medical and athletic applications.
- Top Cited PapersOpen Access
- 4 July 2019
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 4 (7) , 1925-1933
A Fully Integrated and Self-Powered Smartwatch for Continuous Sweat Glucose Monitoring
Wearable devices for health monitoring and fitness management have foreseen a rapidly expanding market, especially those for noninvasive and continuous measurements with real-time display that provide practical convenience and eliminated safety/infection risks. Herein, a self-powered and fully integrated smartwatch that consists of flexible photovoltaic cells and rechargeable batteries in the forms of a “watch strap”, electrochemical glucose sensors, customized circuits, and display units integrated into a “dial” platform is successfully fabricated for real-time and continuous monitoring of sweat glucose levels. The functionality of the smartwatch, including sweat glucose sensing, signal processing, and display, can be supported with the harvested/converted solar energy without external charging devices. The Zn-MnO2 batteries serve as intermediate energy storage units and the utilization of aqueous electrolytes eliminated safety concerns for batteries, which is critical for wearable devices. Such a wearable system in a smartwatch fashion realizes integration of energy modules with self-powered capability, electrochemical sensors for noninvasive glucose monitoring, and in situ and real-time signal processing/display in a single platform for the first time. The as-fabricated fully integrated and self-powered smartwatch also provides a promising protocol for statistical study and clinical investigation to reveal correlations between sweat compositions and human body dynamics.
- 4 July 2019
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 4 (7) , 1925-1933
Top Cited PapersOpen AccessA Fully Integrated and Self-Powered Smartwatch for Continuous Sweat Glucose Monitoring
Wearable devices for health monitoring and fitness management have foreseen a rapidly expanding market, especially those for noninvasive and continuous measurements with real-time display that provide practical convenience and eliminated safety/infection risks. Herein, a self-powered and fully integrated smartwatch that consists of flexible photovoltaic cells and rechargeable batteries in the forms of a “watch strap”, electrochemical glucose sensors, customized circuits, and display units integrated into a “dial” platform is successfully fabricated for real-time and continuous monitoring of sweat glucose levels. The functionality of the smartwatch, including sweat glucose sensing, signal processing, and display, can be supported with the harvested/converted solar energy without external charging devices. The Zn-MnO2 batteries serve as intermediate energy storage units and the utilization of aqueous electrolytes eliminated safety concerns for batteries, which is critical for wearable devices. Such a wearable system in a smartwatch fashion realizes integration of energy modules with self-powered capability, electrochemical sensors for noninvasive glucose monitoring, and in situ and real-time signal processing/display in a single platform for the first time. The as-fabricated fully integrated and self-powered smartwatch also provides a promising protocol for statistical study and clinical investigation to reveal correlations between sweat compositions and human body dynamics.
- Top Cited Papers
- 20 June 2018
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 12 (7) , 6978-6987
Roll-to-Roll Gravure Printed Electrochemical Sensors for Wearable and Medical Devices
As recent developments in noninvasive biosensors spearhead the thrust toward personalized health and fitness monitoring, there is a need for high throughput, cost-effective fabrication of flexible sensing components. Toward this goal, we present roll-to-roll (R2R) gravure printed electrodes that are robust under a range of electrochemical sensing applications. We use inks and electrode morphologies designed for electrochemical and mechanical stability, achieving devices with uniform redox kinetics printed on 150 m flexible substrate rolls. We show that these electrodes can be functionalized into consistently high performing sensors for detecting ions, metabolites, heavy metals, and other small molecules in noninvasively accessed biofluids, including sensors for real-time, in situ perspiration monitoring during exercise. This development of robust and versatile R2R gravure printed electrodes represents a key translational step in enabling large-scale, low-cost fabrication of disposable wearable sensors for personalized health monitoring applications.
- 20 June 2018
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 12 (7) , 6978-6987
Top Cited PapersRoll-to-Roll Gravure Printed Electrochemical Sensors for Wearable and Medical Devices
As recent developments in noninvasive biosensors spearhead the thrust toward personalized health and fitness monitoring, there is a need for high throughput, cost-effective fabrication of flexible sensing components. Toward this goal, we present roll-to-roll (R2R) gravure printed electrodes that are robust under a range of electrochemical sensing applications. We use inks and electrode morphologies designed for electrochemical and mechanical stability, achieving devices with uniform redox kinetics printed on 150 m flexible substrate rolls. We show that these electrodes can be functionalized into consistently high performing sensors for detecting ions, metabolites, heavy metals, and other small molecules in noninvasively accessed biofluids, including sensors for real-time, in situ perspiration monitoring during exercise. This development of robust and versatile R2R gravure printed electrodes represents a key translational step in enabling large-scale, low-cost fabrication of disposable wearable sensors for personalized health monitoring applications.