ANAnna Te Water Naudé

Anna Te Water Naudé

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Anna Te Water Naudé has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Amedine Duret

    School of Clinical Medicine, University of Cambridge, Cambridge, UK

    1 shared publication
  • Conor Reid

    School of Clinical Medicine, University of Cambridge, Cambridge, UK

    1 shared publication
  • Louise Allen

    Department of Ophthalmology, Cambridge University Hospitals NHS Foundation Trust, Cambridge Biomedical Research Campus, Hills Road, Cambridge, CB2 0QQ, United Kingdom, 44 1223 216700

    1 shared publication
  • Robert Humphries

    School of Clinical Medicine, University of Cambridge, Cambridge, UK

    1 shared publication
  • Sushmita Ramanujam

    School of Clinical Medicine, University of Cambridge, Cambridge, UK

    1 shared publication

Latest Publications

  • The infrared reflex: a potential new method for congenital cataract screening

    by Amedine Duret, Robert Humphries, Sushmita Ramanujam, Anna Te Water Naudé, Conor Reid, Louise E. Allen

    Objective To compare the accuracy of infrared (IR)-reflex assessment using a prototype imaging device to standard non-mydriatic red-reflex screening with direct ophthalmoscope (DO) in the diagnosis of neonatal and childhood cataract. Methods The comparison of the techniques was made in two distinct cohorts: in the first, newborns underwent IR and red-reflex testing by a medical student, with results compared to a reference red-reflex examination by an experienced midwife. In the second, an enriched cohort of children attending a specialist paediatric ophthalmology clinic had IR and red-reflex testing by a medical student to reference examination by a paediatric ophthalmologist. The medical students were considered inexperienced screeners due to their limited exposure to ophthalmology. The sensitivity and specificity of the IR and red-reflex assessments in respect to reference examination were calculated. Diagnostic accuracy was compared in Caucasian and non-Caucasian eyes. Results IR and red-reflex imaging were possible in all 180 neonatal eyes examined. A total of 5% of newborn eyes were found to have embryological remnants in the anterior segment of the eye with IR-reflex imaging which were not detected on reference red-reflex examination. IR-reflex assessment had significantly better sensitivity (100 vs 71%, p < 0.05) and specificity (100 vs 63%, p < 0.01) than red-reflex assessment in the diagnosis of childhood cataract. Red-reflex specificity was particularly poor in non-Caucasian eyes compared to Caucasian eyes (32 vs 72%, p < 0.05). Conclusion This pilot study indicates that IR-reflex imaging has the potential to improve the diagnostic accuracy of eye screening for cataract by inexperienced healthcare staff, particularly in non-Caucasian children.