FJFarahiyah Jasni

Farahiyah Jasni

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Farahiyah Jasni has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Advancing mobile robot navigation with DRL and heuristic rewards: A comprehensive review

    by Mazbahur Rahman Khan, Azhar Mohd Ibrahim, Suaib Al Mahmud, Farah Asyiqin Samat, Farahiyah Jasni, Muhammad Imran Mardzuki


  • Open Access

    Exploring the Efficacy of Piezoelectric-Based Sensory Systems for Heart Rate Monitoring in Differentiating Stress vs. Relax Conditions

    by Muhammad Hafiz Zulhilmi Zulkifli, Farahiyah Jasni, Aimi Shazwani Ghazali, Nor Hidayati Diyana Nordin, Shahrul Na'IM Sidek, Syamimi Mardiah Shaharum, Fadhlan Hafizhelmi Kamaru Zaman

    Stress has diverse effects on human physiological reactions, and one such effect is on heart rate (HR). The established methods to acquire HR is by electrocardiogram (ECG) and photoplethysmogram (PPG). ECG electrodes need to be placed on the chest, which can cause inconvenience and is not practical in daily life, while PPG signals are known to contain more noise than ECG. Thus, this work aims to investigate the efficacy of a piezoelectric-based sensory system in measuring HR and using the signal to differentiate stressed and relaxed conditions by means of statistical analysis. Two activities were conducted to achieve the goal. The first experiment involved collecting and analysing piezoelectric signals to measure the pulse rate (bpm) and compare this with the HR from PPG. For the second experiment, the piezoelectric-based HR was calculated from 20 subjects (male and female, age ranging between 20 and 25) in relaxed and stressed conditions. The stress condition was triggered using two stressors: the Stroop Colour Word Test and the Digit Span Test. Statistical analyses reveal a strong positive correlation between piezoelectric-based heart rate (HR) and oximeter readings (r(12) = 0.993, p < 0.001), despite the fact that the values are not precisely identical. In addition, the findings also indicate that there are significant effects by the mental states (stressed and relaxed) on the piezoelectric-based HR readings (p<0.05). Employing a within-subject design condition, the results further illustrated that piezoelectric readings are elevated during stressed conditions (Mean±SD = 72.395±0.097) and diminished during relaxed conditions (Mean±SD = 71.615±0.126). Therefore, the suggested piezoelectric-based sensory system has been validated as an effective means of categorizing stress and relaxation based on heart rate signals. ABSTRAK: Tekanan mempunyai pelbagai kesan terhadap reaksi fisiologi manusia dan satu daripadanya adalah kadar denyut jantung (HR). Kaedah biasa bagi mengetahui HR adalah melalui elektrokardiogram (ECG) dan fotofetismogram (PPG). Elektrod ECG perlu dipasang pada dada di mana boleh menyebabkan ketidakselesaan dan tidak praktikal dalam kehidupan seharian, manakala isyarat PPG diketahui mengandungi lebih banyak bunyi berbanding ECG. Oleh itu, kajian ini bertujuan mengkaji kecekapan ystem deria berdasarkan piezoeletrik bagi mengukur HR dan menggunakan isyarat ini bagi membezakan keadaan tertekan atau tenang melalui cara analisis ystemic. Bagi mencapai tujuan ini, dua aktiviti dijalankan. Pertama eksperimen melibatkan pengumpulan dan analisis isyarat piezoeletrik bagi mengukur kadar nadi (bpm) dan membandingkan HR daripada PPG. Eksperimen kedua, HR berdasarkan piezoelektrik dikira dari 20 subjek (lelaki dan ystemic, berumur antara 20 dan 25) dalam keadaan tenang dan tertekan. Keadaan tertekan dibuat melalui dua ystemi: Ujian Stroop Patah Warna dan Ujian Rentang Digit. Analisis ystemic mendedahkan hubungkait yang kuat antara kadar denyut jantung (HR) berdasarkan piezoeletrik dan bacaan oksimeter (r(12) = 0.993, p < 0.001), walaupun bacaan tidak benar-benar serupa. Tambahan, penemuan ini menunjukkan terdapat kesan penting terhadap tahap mental (tertekan dan tenang) pada bacaan denyut jantung (HR) berdasarkan piezoeletrik (p<0.05). Dengan mengaplikasi keadaan reka bentuk subjek, dapatan menunjukkan bacaan piezoeletrik meningkat ystem keadaan tertekan (Mean±SD = 72.395±0.097) dan kurang ystem keadaan tenang (Mean±SD = 71.615±0.126). Oleh itu, ystem deria berdasarkan piezoeletrik telah diuji berkesan dalam mengkategori keadaan tertekan dan tenang berdasarkan isyarat denyut jantung.

  • Enhancing Mental Health Through Ambient Lighting

    by Ilhamy Isyraq bin Ahmad Fadzil, Aimi Shazwani Ghazali, Farahiyah Jasni, Muhammad Hariz bin Hafizalshah


  • Sensory Systems in Micro-Processor Controlled Prosthetic Leg: A Review

    by Nur Azah Hamzaid, Nur Hidayah Mohd Yusof, Farahiyah Jasni

    Micro-processor controlled prosthetic legs (MPCPL) offer better functionality than conventional prosthetic legs as they use actuators to replace missing joint function. This potentially reduces the user’s metabolic energy consumption and normal walking gait can be mimicked as closely as possible. However, MPCPL require a good control system to perform efficiently, and one of the essential components is the system of sensors. The sensory system must satisfy two important criteria; the practicality in donning and doffing the prosthesis, i.e. the process of putting on and taking off the prosthesis by the amputee user, and the quality in the information provided. In this paper, a comprehensive review was conducted on studies related to the state of the art of sensory system adopted in MPCPL. The publications were searched using four electronics databases within the last 13 years. A total of 31 papers were reviewed. The articles were classified into three main categories: prosthetic-device oriented, user’sbiological-input oriented and neuro-mechanical fusion sensory system. Types of sensors used and their application to the prosthetic system were analyzed. This review indicates that the sensors technology reported in the literature still does not fulfil the criteria of an efficient sensory system. Hence, a sensory system that eases the don and doff process of the prosthesis, yet informative in terms of providing enough useful data to effectively control the prosthesis, is needed for a successful MPCPL.


  • Feasibility of a Gait Phase Identification Tool for Transfemoral Amputees Using Piezoelectric- Based In-Socket Sensory System

    by Farahiyah Jasni, Nur Azah Hamzaid, Tawfik Yahya Al-Nusairi, Nur Hidayah Mohd Yusof, Hanie Nadia Shasmin, Siew-Cheok Ng

    Gait detection is crucial especially in active prosthetic leg control mechanism. Vision system, floor sensors, and wearable sensors are the popular methods proposed to collect data for gait detection. However, in active prosthetic leg control, a tool that is practical in its implementation and is able to provide rich gait information is important for effective manipulation of the prosthetic leg. This paper aims to ascertain the feasibility of the piezoelectric-based in-socket sensory system that is hypothesized to be practical in implementation and provide sufficient information as a wearable gait detection tool for transfemoral prosthetic users. Fifteen sensors were instrumented to the anterior and posterior internal wall of a quadrilateral socket. One transfemoral amputee subject donned the instrumented socket and performed two walking routines; single stride and continuous walking. The sensors’ responses from both routines were analyzed with respect to the gait phases. The results suggested that the sensors output signal corresponds to the force components behavior of the stump while performing gait. All sensors were seen active during the first double support period (DS1). The anterior sensors were prominent during the initial swing (Sw), while posterior sensors were active during terminal Sw. These findings correspond with the muscle activity during the respective phases. Besides, the sensors also show significant pattern during single support and the second double support (DS2) phase. Thus, it can be deduced that the proposed sensory system is feasible to be used as a gait phase identification tool.