WSWon Chul Shin

Won Chul Shin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Won Chul Shin has a total of 138 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An Integrated Analysis of Factors Influencing Acceptance of Care Robots Among Older Korean Adults

    by Hee Jeong Yoon, Si Woo Ban, Yeo Min Han, Hye Ri Shin, Young Sun Kim, Won Chul Shin, Seung Don Yoo, Ji Ho Park

    Background: As populations rapidly age, care robots have been proposed as a promising solution, supporting independent living and alleviating care burdens. However, acceptance of care robots among older adults remains limited. This study examined the relative contributions of demographic, health-related, digital competence, and technology-related psychological factors to care robot acceptance among older adults in South Korea. Methods: A cross-sectional survey was conducted with 506 community-dwelling older adults. Hierarchical multiple regression analyses were used to identify predictors of care robot acceptance, sequentially entering demographic characteristics, health-related factors, digital competence, and technology-related psychological variables. Results: Demographic and health-related factors were initially associated with care robot acceptance, but their effects diminished after accounting for digital competence and psychological variables. In the final model, technology-related psychological factors—particularly technology use self-efficacy and technology enthusiasm—were the strongest predictors of acceptance, while most demographic and health variables became non-significant, with the exception of instrumental activities of daily living (IADLs). Conclusions: These findings indicate that psychological readiness and confidence in technology use outweigh demographic or health characteristics in shaping older adults’ acceptance of care robots. Interventions and design strategies that enhance self-efficacy, foster positive engagement, and support functional independence may be critical for promoting the effective and sustainable adoption of care robots in aging societies.


  • Cephalometric differences between patients with REM- and NREM-Predominant OSA: implications for selecting surgical candidates

    by Muhang Lee, Yujin Jee, Jung-Ick Byun, Won Chul Shin, Sung Ok Hong

    Purpose Obstructive sleep apnea (OSA) is a common disorder characterized by recurrent upper airway collapse, causing intermittent hypoxemia and sleep disruption. Various factors influence its occurrence and severity. This study aimed to examine the relationship between cephalometric anatomical features and polysomnographic data in patients with OSA. Methods This retrospective cohort study included 74 patients (61 male, 13 female) aged 18–78 years(mean ± SD: 52.9 ± 12.8 years), with BMI ranging 17.6–34 kg/m²(mean ± SD: 25.6 ± 3.1 kg/m²), diagnosed with OSA, who also underwent cephalometric, and panoramic radiographs. Patients were classified into positional OSA (n = 33, 28 males, 5 females), non-positional OSA (n = 41, 33 males, 8 females), REM-related OSA (n = 22, 14 males, 8 females) and NREM-related OSA (n = 52, 47 males, 5 females) based on polysomnographic data. The primary predictor variables were OSA subtype. The primary outcome variables included PSG data and lateral and posteroanterior cephalometric measurements. Group differences between OSA subtypes and correlation coefficient between PSG and cephalometric parameters were evaluated. Logistic regression analyses were performed to identify risk factor. Results No significant differences in cephalometric and panoramic parameters were found between patients with POSA and NPOSA. NREM OSA patients had a longer N-ANS length, greater anterior hyoid-to-mandibular plane, and longer tongue length than REM OSA patients (p < 0.05). Logistic regression revealed that narrower nasal and maxillary widths (relative to mandibular width) were significant risk factors for NPOSA (95% CI, p < 0.05). A posteriorly and inferiorly positioned hyoid bone and a longer tongue length were associated with NREM OSA. Conclusion Anatomical factors, including nasal and maxillary width, hyoid bone position, and tongue length, are linked to OSA type. These findings may suggest that targeted treatments strategies, including MAD, MMA, genioglossus advancement, or transverse maxillary expansion, may be effective based on individual anatomical characteristics.

  • Open Access

    Risk of new-onset seizures following immunization against COVID-19: a self-controlled case-series study

    by Hwa Yeon Ko, Dongwon Yoon, Ju Hwan Kim, Han Eol Jeong, Seung Bong Hong, Won-Chul Shin, Ju-Young Shin

    OBJECTIVES: Despite emerging reports of new-onset seizures (NOS) following coronavirus disease 2019 (COVID-19) vaccination, safety evidence regarding the risk of NOS after vaccination remains limited. We aimed to investigate the potential association between NOS and COVID-19 vaccination.METHODS: We conducted a self-controlled case series study utilizing a nationwide database linking the COVID-19 vaccination registry and the National Health Information Database (from February 2021 to October 2022). We identified adults (≥18 years) who received COVID-19 vaccination (BNT162b2, ChAdOx1 nCoV-19, mRNA-1273, NVX-CoV2373, or Ad26.COV2.S) and had a diagnosis of NOS accompanied by prescriptions of anti-seizure drugs. The observation period was defined as 240 days following vaccination. We evaluated the risk of NOS during a risk window of 28 days after vaccination compared to the control window (the remaining observation period excluding the risk window). Incidence rate ratios (IRRs) with 95% confidence intervals (CIs) were estimated using a conditional Poisson regression model.RESULTS: Among 42,155,198 COVID-19 vaccine recipients, we identified 1,849 and 4,217 patients with NOS in the risk and control windows, respectively. There was no increased risk of NOS within the 28-day period following vaccination (IRR, 0.99; 95% CI, 0.94 to 1.05). Although results from subgroup analyses by vaccine type were largely consistent with the main findings (IRR, 0.95; 95% CI, 0.88 to 1.03 for BNT162b2; IRR, 0.95; 95% CI, 0.77 to 1.16 for ChAdOx1 nCoV-19; IRR, 1.58; 95% CI, 0.52 to 4.83 for Ad26.COV2.S), a marginally elevated risk was observed for mRNA-1273 (IRR, 1.21; 95% CI, 1.04 to 1.42).CONCLUSIONS: There was no evidence of an increased risk of NOS following COVID-19 vaccination. These findings can be used as safety evidence in clinical decision-making and to bolster public confidence in COVID-19 vaccines.

  • Machine learning classifier solving the problem of sleep stage imbalance between overnight sleep

    by Chanwoo Park, Jung-Ick Byun, Sang Ho Choi, Won Chul Shin

    Feature extraction follows the American Academy of Sleep Medicine (AASM) sleep score manually and applies it to machine learning with a focus on the generalization of sleep data to enable data-centric artificial intelligence. In real-world clinical testing, the manual scoring of sleep stages is time-consuming and requires significant expertise. Additionally, it is subject to interobserver subjective bias. Machine-learning techniques offer a way to overcome these limitations through automation. However, machine learning for sleep phase prediction can perform poorly for small classes. If the distribution of the training data was unbalanced, the model was trained with a bias toward the majority class. To address this, we experimented with loss function adjustment and resampling methods that assign more weight to the prediction errors of minority classes in sleep scoring to determine how to overcome the data imbalance problem. Machine learning can also be used to compare the accuracy of each channel in identifying electrodes, which should be monitored more closely in real-world clinical testing. Owing to the small amount of data available for machine learning in this study, we used various machine learning classifiers by increasing or decreasing the dataset using sampling techniques and weighting different classes of sleep stages. In our experiments, the best-performing model for classifying sleep stages had an accuracy of 91.9%, kappa of 0.899, and F1-score of 86.9%.


  • Open Access

    Effect of Parietal High-Definition Transcranial Direct Current Stimulation on Cognitive Function in REM Sleep Behavior Disorder With Mild Cognitive Impairment: A Sham-Controlled Pilot Study

    by Jung-Ick Byun, Kang-Min Choi, Won Chul Shin, Ki-Young Jung

    Byun JI, et al. J Clin Neurol. 2025 Sep;21(5):467-469. https://doi.org/10.3988/jcn.2025.0162

  • Open Access

    Efficacy and Safety of Pregabalin for Restless Legs Syndrome in Korean Adults: A Randomized, Double-Blind, Placebo-Controlled Trial

    by Jun-Sang Sunwoo, Yong Won Cho, Won Chul Shin, Jung-Ick Byun, Jung-Won Shin, Ki-Young Jung

    Sunwoo JS, et al. J Clin Neurol. 2025 Jun;21:e23. https://doi.org/10.3988/jcn.2025.0092


  • Open Access

    Low arousal threshold is associated with altered functional connectivity of the ascending reticular activating system in patients with obstructive sleep apnea

    by Jung-Ick Byun, Geon-Ho Jahng, Chang-Woo Ryu, Soonchan Park, Kun Hee Lee, Sung Ok Hong, Ki-Young Jung, Won Chul Shin

    A low arousal threshold (LAT) is a pathophysiological trait of obstructive sleep apnea (OSA) that may be associated with brainstem ascending reticular activating system-cortical functional connectivity changes. We evaluated resting-state connectivity between the brainstem nuclei and 105 cortical/subcortical regions in OSA patients with or without a LAT and healthy controls. Twenty-five patients with moderate to severe OSA with an apnea–hypopnea index between 20 and 40/hr (15 with and 10 without a LAT) and 15 age- and sex-matched controls were evaluated. Participants underwent functional magnetic resonance imaging after overnight polysomnography. Three brainstem nuclei—the locus coeruleus (LC), laterodorsal tegmental nucleus (LDTg), and ventral tegmental area (VTA)—associated with OSA in our previous study were used as seeds. Functional connectivity values of the two brainstem nuclei (LC and LDTg) significantly differed among the three groups. The connectivity of the LC with the precuneus was stronger in OSA patients than in controls regardless of the concomitant LAT. The connectivity between the LDTg and the posterior cingulate cortex was also stronger in OSA patients regardless of the LAT. Moreover, OSA patients without a LAT showed stronger LDTg-posterior cingulate cortex connectivity than those with a LAT (post hoc p = 0.013), and this connectivity strength was negatively correlated with the minimum oxygen saturation in OSA patients (r = − 0.463, p = 0.023). The LAT in OSA patients was associated with altered LDTg-posterior cingulate cortex connectivity. This result may suggested that cholinergic activity may play a role in the LAT in OSA patients.


  • Open Access

    Effect of Non-Invasive Brain Stimulation on Sleep and Sleep Disorders

    by Jung-Ick Byun, Won Chul Shin, Ki-Young Jung

    Non-invasive brain stimulation (NIBS), including transcranial magnetic and electrical stimulations, has recently been used to modulate sleep and treat sleep disorders. Herein, we reviewed studies that used NIBS to modulate sleep in healthy populations or patients with sleep disorders. Repetitive transcranial magnetic stimulation enhanced sleep slow oscillations and consistently improved subjective symptoms in patients with insomnia and restless legs syndrome. Transcranial electrical stimulation also increased slow-wave sleep in healthy populations and improved subjective sleep symptoms in patients with insomnia. Individualized NIBS and other NIBS techniques may be promising for treating sleep disorders, and future studies are warranted to determine optimal stimulation parameters and evaluate their long-term safety.