ZJZhenzhen Jiang

Zhenzhen Jiang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhenzhen Jiang has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Compact Dual-Band Metantenna on PDMS Substrate for WBAN Applications

    by Zhenzhen Jiang, Zijian Dong, Pengfei Song, Mark Leach, Yi Huang

    A compact dual-band metantenna for wireless body area network (WBAN) applications is presented. The design is realized using conductive fabrics on a polydimethylsiloxane (PDMS) substrate, ensuring flexibility. The dual-band periodic metasurface exhibits polarization-insensitive behavior from 0° to 90° under normal incidence and maintains stable performance over a wide range of oblique incidence angles. Measured impedance bandwidths of 840 MHz and 1120 MHz are achieved at 2.45 GHz and 5.8 GHz. Anechoic-chamber measurements confirm stable S-parameters and radiation characteristics under bending conditions. The metasurface enhances the realized gain by 115.7% at 2.45 GHz and 103.7% at 5.8 GHz. On-body SAR evaluations demonstrate compliance with safety standards. The results indicate that the proposed antenna is suitable for wearable WBAN applications.


  • Facile Laser-Cutting Process for Nanocellulose-Paper-Based Microfluidic Microchannel Fabrication

    by Miao Lu, Wenwen Yuan, Ruiqi Yong, Hang Yuan, Zhenzhen Jiang, Yucheng Gong, Fuzhou Niu, Pengfei Song

    Nanofibrillated cellulose paper (nanopaper) has drawn increasing attention as a potential material for various areas, due to its extremely smooth surface, excellent optical transparency and sequent nanofiber matrix. To extend nanopaper application as the analytical platform, nanopaper-based microfluidics has quickly advanced recently. However, the current method of patterning microchannels on nanopaper which is the basic for establishing microfluidic (i.e., 3D printing and spray coating), still has some limitations, including low precision and long preparation time. So, in this study, we utilized laser cutting to fabricate microchannel patterns on nanopaper by burning the surface of nanopaper. Through systematic parameters (laser cutting speed and power) optimization, we identified the optimal laser cutting conditions, enhancing both efficiency and accuracy. The minimum depth and width of the microchannels were reduced to 15 μm and 58 μm, respectively. The entire fabrication process, including drying, was completed in less than 35 minutes. Compared to the existing methods, this method has smaller microchannels size, time saving and no need for additional molds or equipment those advantages which contribute its novelty and accuracy. By arranging different shapes of lines, microchannels for various sensing were developed. As a proof-of-concept, we developed two functional nanopaper-based analyzer devices (NanoPADs). With a detection limit of 2.2 mM for glucose and 281 fM for Rhodamine B (RhB), both demonstrating excellent performance and low detection limits. The results indicate that our laser-cutting nanopaper microchannels may serve as a platform for developing high-performance analytical devices which may spark the development of nanopaper in the future.


  • A 403 MHz Wireless Power Transfer System With Tuned Split-Ring Loops for Implantable Medical Devices

    by Jingchen Wang, Eng Gee Lim, Mark Paul Leach, Zhao Wang, Rui Pei, Zhenzhen Jiang, Yi Huang

    A near-field wireless power transfer (WPT) system for implantable medical devices, such as pacemakers, is proposed. Operating at 403 MHz within the medical implants communication service (MICS) band, the WPT link constitutes a primary loop to be based outside the body as a transmitter and an implantable loop with a single-turn as a receiver. Simulation and experimental results show that the proposed link offers good power transfer efficiency (PTE) performance. The maximum measured PTE of the proposed link is 57.9% at a transfer distance of 6 mm through 1 mm of air and 5 mm of body tissue. The maximum input power that can be supplied to stay within specific absorption rate safety guidelines is 159 mW. A rectifying circuit is designed to convert 403 MHz RF signals to dc for a 1.5 $\text{k}\Omega $ load with a measured conversion efficiency of 73.2%. The measured end-to-end PTE of the proposed WPT system is 42.4%.


  • Wearable Belt Antenna for Body Communication Networks

    by Rui Pei, Mark Leach, Eng Gee Lim, Zhao Wang, Jingchen Wang, Yuanchen Wang, Zhenzhen Jiang, Yi Huang

    This paper presents a dual-band wearable belt antenna design offering stable performance for both on and off body scenarios. The proposed antenna is composed of a metal buckle and a lossy leather substrate. A layer of conductive fiber is attached to the leather to provide isolation between the human body and the radiating element. A novel snap-on button structure is used as the antenna feed. The antenna can achieve an on body realized gain of 5.10 dBi at 2.45 GHz, 4.05 dBi at 5.2 GHz and 3.31 dBi at 5.8 GHz. A specific absorption rate of 0.87 W/kg is achieved. The on/off body radiation efficiency of the antenna is measured in a reverberation chamber. The antenna can operate in both on and off-body communication as the frequency shift induced by the human body tissue is not significant. The proposed belt antenna is a low-cost and reliable solution for smart on-body applications


  • Symbol-Splitting-Based Simultaneous Wireless Information and Power Transfer System for WPAN Applications

    by Zhenzhen Jiang, Zhao Wang, Mark Leach, Eng Gee Lim, Hao Zhang, Rui Pei, Yi Huang

    A compact system design for simultaneous wireless information and power transfer (SWIPT) based on a novel symbol-splitting (SS)-technique is proposed in this letter. A rat-race coupler is adopted between the receiving terminal and the rectifier to facilitate the separation and isolation of the noninformation-carrying components of the received signal from the information-carrying components for rectification and data recovery, respectively. The maximum conversion efficiency of the design reaches over 60% with −4-dBm input power and remains around 50% down to input powers of −10 dBm in measurements using both continuous-wave (CW) signals and modulated signals with different data rates as inputs. The transferred data are correctly received and recovered at the isolation port of the coupler. The design is $51.7\times49.3$ mm 2 , and all measurement results show good agreement with the simulation results.


  • Wearable EBG-Backed Belt Antenna for Smart On-Body Applications

    by Rui Pei, Mark Paul Leach, Eng Gee Lim, Zhao Wang, Chaoyun Song, Jingchen Wang, Wenzhang Zhang, Zhenzhen Jiang, Yi Huang

    This article presents an innovative belt antenna with an electromagnetic band-gap (EBG) ground plane made of textile materials. The antenna can be applied in a smart belt system to set up a communication link with other electronic devices and/or host a variety of sensors to track human motions. The proposed belt antenna works at 2.45 GHz in the industrial, scientific, and medical radio band for Bluetooth low energy communications. Considering the effect the human body would have on the performance of a belt antenna, a textile ground plane is designed to be integrated into the trouser fabric behind the belt to provide isolation from the body and simultaneously improve antenna radiation characteristics. Through the application of the ground plane, the belt antenna achieves a maximum realized gain of 7.94 dBi and a minimum specific absorption rate of 0.04 W/kg at 0.5 W input power. During the design process, characteristic mode analysis is used to explore the underlining principle and further optimize the antenna performance. Two typical EBG structures are analyzed in detail for this application scenario. The suspended transmission line method is used to evaluate EBG performance variations when the textile ground plane is bent. A prototype of such a system is fabricated and tested. Experimental results shows that the belt antenna, together with the textile EBG ground plane, is an excellent candidate for a smart belt system with desirable radiation pattern, efficiency, and safety limit.


  • Open Access

    A Conformal Split-Ring Loop as a Self-Resonator for Wireless Power Transfer

    by Jingchen Wang, Mark Paul Leach, Eng Gee Lim, Zhao Wang, Zhenzhen Jiang, Rui Pei, Yi Huang

    A conventional printed spiral coil (PSC) has a self-resonant frequency and its equivalent circuit is a parallel inductor-capacitor (LC) circuit. It is desirable to use PSC’s in wireless power transfer (WPT) applications, however these are most commonly constituted by a series-primary and series- or parallel-secondary circuit. This paper proposes a printed conformal split-ring loop with the characteristic of a series LC circuit at its resonance frequency. Regarding the loop as a self-resonator, a magnetic resonance coupled (MRC) WPT system with series-primary and secondary operating at 433 MHz in the Industrial Scientific and Medical (ISM) band is presented. The maximum measured power transfer efficiency is 87.9% at a transfer distance of 22 mm, the best reported result for such a configuration.


  • Wideband Loop Antenna With Split-Ring Resonators for Wireless Medical Telemetry

    by Zhenzhen Jiang, Zhao Wang, Mark Leach, Eng Gee Lim, Jingchen Wang, Rui Pei, Yi Huang

    This letter presents a wideband flexible loop antenna with split ring resonators (SRRs) for use in wireless medical telemetry. This design covers the entire MedRadio band (401 406 MHz) and four Industrial Scientific Medical ISM bands (433.1-434.8, 868.0-868.8, 902.8-928.0 MHz and 2.4-2.48 GHz). The SRRs improve the return loss of the loop and reduce the power absorbed inside the human body over the multiband frequency ranges. They also lead to improved radiation efficiency, gain and transmission coefficient in comparison to the structure without the SRRs. The CST voxel human model has been used to study and optimise antenna performance in a realistic environment and shows a reduction in specific absorption rate (SAR) when the SRRs are utilised. Measurements are conducted in a tissue-simulating liquid phantom and show good agreement with the simulations. This novel antenna could be used for a range of implantable applications such as wireless data transmission and wireless power transfer.