Han Yao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Han Yao has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Ferruccio Renzoni
Department of Physics and Astronomy, University College London, London, U.K.
9 shared publications - Benjamin Maddox
Department of Physics, Durham University, Durham, United Kingdom
3 shared publications Benjamin Maddox
UCL, Dept Phys & Astron, Gower St, London WC1E 6BT, England
2 shared publications- Cameron Deans
Department of Physics and Astronomy, University College London , Gower Street, London WC1E 6BT, United Kingdom
2 shared publications Danyue Ma
School of Instrumentation Science and Opto-Electronics Engineering, Beihang University, No. 37 Xueyuan Road, Haidian District, Beijing 100083, China
2 shared publicationsJunpeng Zhao
School of Instrumentation Science and Opto-Electronics Engineering, Beihang University, No. 37 Xueyuan Road, Haidian District, Beijing 100083, China
2 shared publications
Latest Publications
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 4505908
Through-Skin Pilot-Hole Detection and Localization With Atomic Magnetometers: Enhanced Penetration via Improved Magnetic Background Stabilization
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 4505908
Through-Skin Pilot-Hole Detection and Localization With Atomic Magnetometers: Enhanced Penetration via Improved Magnetic Background Stabilization
- 16 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-7
Fast Electromagnetic Induction Imaging With Unshielded Radio Frequency Atomic Magnetometers in Phase-Lock Mode
We demonstrate an apparatus for electromagnetic induction imaging in unshielded environment based on radio-frequency atomic magnetometers in phase-lock mode. The presented results reveal the superior performance of the new apparatus with respect to the standard one based on atomic magnetometers operating in the conventional fluxgate-lock mode. In particular, the superior stability of the new apparatus results in a reduction by a factor of 50 times in the number of measurements required to produce an image, with corresponding speed-up of image acquisition.
- 16 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-7
Fast Electromagnetic Induction Imaging With Unshielded Radio Frequency Atomic Magnetometers in Phase-Lock Mode
We demonstrate an apparatus for electromagnetic induction imaging in unshielded environment based on radio-frequency atomic magnetometers in phase-lock mode. The presented results reveal the superior performance of the new apparatus with respect to the standard one based on atomic magnetometers operating in the conventional fluxgate-lock mode. In particular, the superior stability of the new apparatus results in a reduction by a factor of 50 times in the number of measurements required to produce an image, with corresponding speed-up of image acquisition.
- 10 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
High-Sensitivity Operation of Unshielded Radio Frequency Atomic Magnetometers Using Phase-Lock Techniques
High-sensitivity operation of radio frequency atomic magnetometers (AMs) in unshielded environment requires compensation of low-frequency fluctuations of the ambient magnetic field. Here, we demonstrate the use of phase-lock (PL) techniques to stabilize the magnetic environment and achieve high sensitivity at high frequencies. This is achieved by using the output of the AM both for stabilization and for measurement purposes. The approach is validated by a proof-of-concept in unshielded environment. The PL approach is also compared to the standard approach, where the magnetic environment is stabilized with the help of a set of fluxgate magnetometers, and it is shown that the PL approach features superior performances in signal detection.
- 10 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
High-Sensitivity Operation of Unshielded Radio Frequency Atomic Magnetometers Using Phase-Lock Techniques
High-sensitivity operation of radio frequency atomic magnetometers (AMs) in unshielded environment requires compensation of low-frequency fluctuations of the ambient magnetic field. Here, we demonstrate the use of phase-lock (PL) techniques to stabilize the magnetic environment and achieve high sensitivity at high frequencies. This is achieved by using the output of the AM both for stabilization and for measurement purposes. The approach is validated by a proof-of-concept in unshielded environment. The PL approach is also compared to the standard approach, where the magnetic environment is stabilized with the help of a set of fluxgate magnetometers, and it is shown that the PL approach features superior performances in signal detection.
- 19 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
Through-Barrier Sub-mm Electromagnetic Induction Imaging With Atomic Magnetometers
Eddy-current non-destructive testing is widely used for the detection of cracks and fatigue in metallic structures. This is usually done by sweeping an inductor coil over the sample of interest, while monitoring changes in the coil response. While this may allow for the detection of sub-mm cracks and defects, the technique lacks of penetrating power through barriers. This work addresses such a capability gaps. We demonstrate a mechanically translatable system based on an atomic magnetometer that allows for sub-mm resolution while simultaneously allowing also for penetration through shields. The adoption of a radio-frequency atomic magnetometer as a sensor allows for the operation of the system at low frequency, with high sensitivity achieved by introducing several technical solutions which lead to enhanced performances, with respect to existing systems, and improved stability of the instrument while scanning over the target object. The obtained enhanced performances are highlighted by the demonstrated ability to detect and image gaps as small as 0.27 mm concealed behind a shield consisting of a 1.50 mm rubber sheet and a 0.42 mm aluminium sheet.
- 19 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
Through-Barrier Sub-mm Electromagnetic Induction Imaging With Atomic Magnetometers
Eddy-current non-destructive testing is widely used for the detection of cracks and fatigue in metallic structures. This is usually done by sweeping an inductor coil over the sample of interest, while monitoring changes in the coil response. While this may allow for the detection of sub-mm cracks and defects, the technique lacks of penetrating power through barriers. This work addresses such a capability gaps. We demonstrate a mechanically translatable system based on an atomic magnetometer that allows for sub-mm resolution while simultaneously allowing also for penetration through shields. The adoption of a radio-frequency atomic magnetometer as a sensor allows for the operation of the system at low frequency, with high sensitivity achieved by introducing several technical solutions which lead to enhanced performances, with respect to existing systems, and improved stability of the instrument while scanning over the target object. The obtained enhanced performances are highlighted by the demonstrated ability to detect and image gaps as small as 0.27 mm concealed behind a shield consisting of a 1.50 mm rubber sheet and a 0.42 mm aluminium sheet.
- Open Access
- 31 July 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (17) , 27287-27295
Neural network-aided optimisation of a radio-frequency atomic magnetometer
Efficient unsupervised optimisation of atomic magnetometers is a requirement in many applications, where direct intervention of an operator is not feasible. The efficient extraction of the optimal operating conditions from a small sample of experimental data requires a robust automated regression of the available data. Here we address this issue and propose the use of general regression neural networks as a tool for the optimisation of atomic magnetometers which does not require human supervision and is efficient, as it is ideally suited to operating with a small sample of data as input. As a case study, we specifically demonstrate the optimisation of an unshielded radio-frequency atomic magnetometer by using a general regression neural network which establishes a mapping between three input variables, the cell temperature, the pump beam power and the probe beam power, and one output variable, the AC sensitivity. The optimisation results into an AC sensitivity of 44 fT/Hz at 26 kHz.
- 31 July 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (17) , 27287-27295
Open AccessNeural network-aided optimisation of a radio-frequency atomic magnetometer
Efficient unsupervised optimisation of atomic magnetometers is a requirement in many applications, where direct intervention of an operator is not feasible. The efficient extraction of the optimal operating conditions from a small sample of experimental data requires a robust automated regression of the available data. Here we address this issue and propose the use of general regression neural networks as a tool for the optimisation of atomic magnetometers which does not require human supervision and is efficient, as it is ideally suited to operating with a small sample of data as input. As a case study, we specifically demonstrate the optimisation of an unshielded radio-frequency atomic magnetometer by using a general regression neural network which establishes a mapping between three input variables, the cell temperature, the pump beam power and the probe beam power, and one output variable, the AC sensitivity. The optimisation results into an AC sensitivity of 44 fT/Hz at 26 kHz.
- 27 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-5
Rapid Electromagnetic Induction Imaging With an Optically Raster-Scanned Atomic Magnetometer
We present an apparatus to overcome the limitations of mechanical raster-scanning in electromagnetic induction imaging (EMI) techniques by instead performing a 2D optical raster-scan within the vapour cell of a radio-frequency atomic magnetometer (RF-AM). A large cuboidal 87 Rb vapour cell is employed to act as the medium of an RF-AM with the pump and probe beams translated in the cell via acousto-optics. The technique is shown to give robust and repeatable magnetic measurements over the cell volume and successfully resolves conductive targets with EMI. Optical raster-scanning removes the limitation of slow mechanical actuation and a fast imaging procedure is enacted resolving conductive targets at a rate of 40 ms/pixel.
- 27 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-5
Rapid Electromagnetic Induction Imaging With an Optically Raster-Scanned Atomic Magnetometer
We present an apparatus to overcome the limitations of mechanical raster-scanning in electromagnetic induction imaging (EMI) techniques by instead performing a 2D optical raster-scan within the vapour cell of a radio-frequency atomic magnetometer (RF-AM). A large cuboidal 87 Rb vapour cell is employed to act as the medium of an RF-AM with the pump and probe beams translated in the cell via acousto-optics. The technique is shown to give robust and repeatable magnetic measurements over the cell volume and successfully resolves conductive targets with EMI. Optical raster-scanning removes the limitation of slow mechanical actuation and a fast imaging procedure is enacted resolving conductive targets at a rate of 40 ms/pixel.
- Open Access
- 21 December 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (1) , 509-511
High-sensitivity operation of an unshielded single cell radio-frequency atomic magnetometer: erratum
An erratum is presented to include the right vertical scale and label in Fig. 2 and Fig. 7, which were omitted in our published manuscript ["High-sensitivity operation of an unshielded single cell radio-frequency atomic magnetometer" Opt. Express 30 (23), 42015 (2022) 10.1364/OE.476016 ].
- 21 December 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (1) , 509-511
Open AccessHigh-sensitivity operation of an unshielded single cell radio-frequency atomic magnetometer: erratum
An erratum is presented to include the right vertical scale and label in Fig. 2 and Fig. 7, which were omitted in our published manuscript ["High-sensitivity operation of an unshielded single cell radio-frequency atomic magnetometer" Opt. Express 30 (23), 42015 (2022) 10.1364/OE.476016 ].
- Open Access
- 31 October 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (23) , 42015-42025
High-sensitivity operation of an unshielded single cell radio-frequency atomic magnetometer
Real-world applications of atomic magnetometers require the ability to operate them with high-sensitivity in the presence of magnetic noise. In the present work, high-sensitivity operation of unshielded atomic magnetometers in a magnetically noisy environment is demonstrated. The distinguishing feature of the demonstrated approach is the implementation of active in-situ bias field stabilization using multiple fluxgate magnetometers. This is combined with the use of a counter-propagating pump and triple-pass probe configuration, to maximize the atomic polarization and the probe rotation respectively, so to reach high-sensitivity. The improvement in sensitivity of the unshielded system with respect to previous realizations is fully characterized, with the contributions of the different modifications of the apparatus individually quantified. The presented set-up is suitable for the detection of long-range magnetic fields, where shielding or differential measurements using multi-sensor set-ups do not constitute viable options.
- 31 October 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (23) , 42015-42025
Open AccessHigh-sensitivity operation of an unshielded single cell radio-frequency atomic magnetometer
Real-world applications of atomic magnetometers require the ability to operate them with high-sensitivity in the presence of magnetic noise. In the present work, high-sensitivity operation of unshielded atomic magnetometers in a magnetically noisy environment is demonstrated. The distinguishing feature of the demonstrated approach is the implementation of active in-situ bias field stabilization using multiple fluxgate magnetometers. This is combined with the use of a counter-propagating pump and triple-pass probe configuration, to maximize the atomic polarization and the probe rotation respectively, so to reach high-sensitivity. The improvement in sensitivity of the unshielded system with respect to previous realizations is fully characterized, with the contributions of the different modifications of the apparatus individually quantified. The presented set-up is suitable for the detection of long-range magnetic fields, where shielding or differential measurements using multi-sensor set-ups do not constitute viable options.
- Open Access
- 5 July 2021
- Published by AIP Publishing in Applied Physics Letters
- Vol. 119 (1) , 014001
Electromagnetic induction imaging with a scanning radio frequency atomic magnetometer
We demonstrate electromagnetic induction imaging with an unshielded, portable radio frequency atomic magnetometer scanning over the target object. This configuration satisfies standard requirements in typical applications, from security screening to medical imaging. The ability to scan the magnetometer over the object relies on the miniaturization of the sensor head, the active compensation of the ambient magnetic field, and the implementation of a dedicated procedure to extract high-quality images from the recorded spatial dependent magnetic resonance. The procedure is shown to be effective in suppressing the detrimental effects of the spatial variation of the magnetic environment.
- 5 July 2021
- Published by AIP Publishing in Applied Physics Letters
- Vol. 119 (1) , 014001
Open AccessElectromagnetic induction imaging with a scanning radio frequency atomic magnetometer
We demonstrate electromagnetic induction imaging with an unshielded, portable radio frequency atomic magnetometer scanning over the target object. This configuration satisfies standard requirements in typical applications, from security screening to medical imaging. The ability to scan the magnetometer over the object relies on the miniaturization of the sensor head, the active compensation of the ambient magnetic field, and the implementation of a dedicated procedure to extract high-quality images from the recorded spatial dependent magnetic resonance. The procedure is shown to be effective in suppressing the detrimental effects of the spatial variation of the magnetic environment.
- 18 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (15) , 6085-6092
Study of Shielding Ratio of Cylindrical Ferrite Enclosure With Gaps and Holes
A stable magnetic field environment is one of the key factors to realize the ultrasensitive magnetic field detection. Ferrite materials, which possess both high electrical resistivity and high permeability, are ideal magnetic shielding materials. Gaps and holes usually exist in the large size magnetic shield which effect shielding effectiveness. In this paper, the variation of the DC magnetic shielding ratio, for different gaps and access hole dimensions, is quantificationally investigated using the finite element method. The shielding ratio in the simulation is close to the theoretical calculation for the closed shield when the thickness of gaps is very small. Our study indicates that gaps and holes separately reduced the shielding effectiveness, and the coexistence of gaps and holes aggravated the reduction of shielding effectiveness. Compared with shielding ratio of the ferrite enclosure without gaps and holes for the known size shield, the transverse and longitudinal direction of the shielding ratio increase by 9% and 274% with gaps (thickness=0.1 mm) and holes (diameter=25 mm), respectively. The simulation results are partially verified with experimentally using cylindrical ferrite shield made of Zn0.17Mn0.74Fe2.06O4 and Zn0.33Mn0.58Fe2.06O4. The difference between the experimental and simulation results is less than 10%.
- 18 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (15) , 6085-6092
Study of Shielding Ratio of Cylindrical Ferrite Enclosure With Gaps and Holes
A stable magnetic field environment is one of the key factors to realize the ultrasensitive magnetic field detection. Ferrite materials, which possess both high electrical resistivity and high permeability, are ideal magnetic shielding materials. Gaps and holes usually exist in the large size magnetic shield which effect shielding effectiveness. In this paper, the variation of the DC magnetic shielding ratio, for different gaps and access hole dimensions, is quantificationally investigated using the finite element method. The shielding ratio in the simulation is close to the theoretical calculation for the closed shield when the thickness of gaps is very small. Our study indicates that gaps and holes separately reduced the shielding effectiveness, and the coexistence of gaps and holes aggravated the reduction of shielding effectiveness. Compared with shielding ratio of the ferrite enclosure without gaps and holes for the known size shield, the transverse and longitudinal direction of the shielding ratio increase by 9% and 274% with gaps (thickness=0.1 mm) and holes (diameter=25 mm), respectively. The simulation results are partially verified with experimentally using cylindrical ferrite shield made of Zn0.17Mn0.74Fe2.06O4 and Zn0.33Mn0.58Fe2.06O4. The difference between the experimental and simulation results is less than 10%.