Ingo Hilschenz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ingo Hilschenz has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Hans-Jürgen Scheer
4 shared publicationsLutz Trahms
4 shared publicationsMartin Burghoff
4 shared publications- Rainer Körber
Physikalisch-Technische Bundesanstalt
4 shared publications Stefan Hartwig
4 shared publicationsGabriel Curio
3 shared publications
Latest Publications
- 1 August 2019
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 305, 138-145
Dynamic nuclear polarisation of liquids at one microtesla using circularly polarised RF with application to millimetre resolution MRI
- 1 August 2019
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 305, 138-145
Dynamic nuclear polarisation of liquids at one microtesla using circularly polarised RF with application to millimetre resolution MRI
- 9 April 2018
- Published by AIP Publishing in Applied Physics Letters
- Vol. 112 (15) , 153703
Toward a magnetic resonance electrical impedance tomography in ultra-low field: A direct magnetic resonance imaging method by an external alternating current
Measuring the electrical impedance of biological tissues in a low frequency range is challenging. Here, we have conducted a superconducting quantum interference device-based microtesla magnetic resonance (MR) imaging study. To obtain an MR image caused by an injected alternating current (ac), we utilized the direct resonance method in which the nuclear spins resonate with the ac magnetic field generated by the external ac current. This method requires an adiabatic pulse and non-adiabatic step-down pulse techniques. The experimental and simulation results agree well with each other and show the feasibility of low-frequency magnetic resonance electrical impedance tomography in the kHz range.
- 9 April 2018
- Published by AIP Publishing in Applied Physics Letters
- Vol. 112 (15) , 153703
Toward a magnetic resonance electrical impedance tomography in ultra-low field: A direct magnetic resonance imaging method by an external alternating current
Measuring the electrical impedance of biological tissues in a low frequency range is challenging. Here, we have conducted a superconducting quantum interference device-based microtesla magnetic resonance (MR) imaging study. To obtain an MR image caused by an injected alternating current (ac), we utilized the direct resonance method in which the nuclear spins resonate with the ac magnetic field generated by the external ac current. This method requires an adiabatic pulse and non-adiabatic step-down pulse techniques. The experimental and simulation results agree well with each other and show the feasibility of low-frequency magnetic resonance electrical impedance tomography in the kHz range.
- 1 January 2017
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 274, 89-94
Remote detected Low-Field MRI using an optically pumped atomic magnetometer combined with a liquid cooled pre-polarization coil
- 1 January 2017
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 274, 89-94
Remote detected Low-Field MRI using an optically pumped atomic magnetometer combined with a liquid cooled pre-polarization coil
- 1 February 2013
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 31 (2) , 171-177
Magnetic resonance imaging at frequencies below 1 kHz
- 1 February 2013
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 31 (2) , 171-177
Magnetic resonance imaging at frequencies below 1 kHz
- 1 December 2011
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 29 (10) , 1365-1373
Are brain currents detectable by means of low-field NMR? A phantom study
- 1 December 2011
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 29 (10) , 1365-1373
Are brain currents detectable by means of low-field NMR? A phantom study
- 1 January 2011
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 56 (2) , 91-97
Simultaneous measurements of somatosensory evoked AC and near-DC MEG signals
Magnetoencephalography measurements of somatosensory evoked brain activity taken inside an extremely magnetically shielded room are reported. The massive low frequency shielding in combination with a high sampling rate enabled the simultaneous observation of AC and near-DC effects. Neuronal activation was achieved by repetitive electrostimulation of the right median nerve above motor threshold using repetition rates from 3 Hz to 12 Hz. Stimulation sequences lasted for 10 s and were interspersed with periods of rest of equal length. The recorded magnetic fields, inferred for the N20m and a sustained near-DC component, revealed mainly dipolar patterns with mutually rotated orientations with angles of rotation of 30° and 75°. At the start of the stimulation we observed a fast rise within 100 ms in the evoked magnetic near-DC fields for which a maximum equivalent current dipole strength of 65 nAm was obtained. The sustained fields decayed by a factor of ∼4 to a lower DC-level B(γ) with a time constant τ of order of seconds. For 12 Hz repetition rate B(γ) was decreased. We suggest that the sustained neuronal activity evoked by repetitive electrostimulation could provide a suitable scheme to realize the direct detection of DC effects of neuronal currents via low field magnetic resonance.
- 1 January 2011
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 56 (2) , 91-97
Simultaneous measurements of somatosensory evoked AC and near-DC MEG signals
Magnetoencephalography measurements of somatosensory evoked brain activity taken inside an extremely magnetically shielded room are reported. The massive low frequency shielding in combination with a high sampling rate enabled the simultaneous observation of AC and near-DC effects. Neuronal activation was achieved by repetitive electrostimulation of the right median nerve above motor threshold using repetition rates from 3 Hz to 12 Hz. Stimulation sequences lasted for 10 s and were interspersed with periods of rest of equal length. The recorded magnetic fields, inferred for the N20m and a sustained near-DC component, revealed mainly dipolar patterns with mutually rotated orientations with angles of rotation of 30° and 75°. At the start of the stimulation we observed a fast rise within 100 ms in the evoked magnetic near-DC fields for which a maximum equivalent current dipole strength of 65 nAm was obtained. The sustained fields decayed by a factor of ∼4 to a lower DC-level B(γ) with a time constant τ of order of seconds. For 12 Hz repetition rate B(γ) was decreased. We suggest that the sustained neuronal activity evoked by repetitive electrostimulation could provide a suitable scheme to realize the direct detection of DC effects of neuronal currents via low field magnetic resonance.
- 7 June 2010
- Published by AIP Publishing in Applied Physics Letters
- Vol. 96 (23) , 233701
On the feasibility of neurocurrent imaging by low-field nuclear magnetic resonance
We describe a nuclear magnetic resonance (NMR) spectrometer operating at with a frequency resolution of 2 mHz to determine the intrinsic linewidth of the proton resonance in the human brain to be about 3 Hz. Using the same system we measured a biomagnetic field of 0.5 to 1 pT amplitude, which was generated by sustained brain activity evoked during repetitive median nerve stimulation. From these data, the effect of neuronal currents on the proton NMR signal was estimated. We conclude that neuronal currents may cause a measurable shift of the proton NMR line of brain tissue in low-fields.- 7 June 2010
- Published by AIP Publishing in Applied Physics Letters
- Vol. 96 (23) , 233701
On the feasibility of neurocurrent imaging by low-field nuclear magnetic resonance
We describe a nuclear magnetic resonance (NMR) spectrometer operating at with a frequency resolution of 2 mHz to determine the intrinsic linewidth of the proton resonance in the human brain to be about 3 Hz. Using the same system we measured a biomagnetic field of 0.5 to 1 pT amplitude, which was generated by sustained brain activity evoked during repetitive median nerve stimulation. From these data, the effect of neuronal currents on the proton NMR signal was estimated. We conclude that neuronal currents may cause a measurable shift of the proton NMR line of brain tissue in low-fields.