YTYoshiaki Takagawa

Yoshiaki Takagawa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yoshiaki Takagawa has a total of 84 co-authors. Here are the top co-authors by number of shared publications:

  • Midori Kita

    Department of Radiology, Tokyo Metropolitan Tama Medical Center, Tokyo, Japan

    7 shared publications
  • Sachiko Izumi

    Department of Radiology, Tokyo Metropolitan Tama Medical Center, Tokyo, Japan

    7 shared publications
  • Kanako Takayama

    Department of Radiation Oncology, Southern Tohoku BNCT Research Center , 7-10 Yatsuyamada, Koriyama-shi, Fukushima 963-8052

    6 shared publications
  • Eiichi Takahashi

    Department of Radiology, Tokyo Metropolitan Tama Medical Center, Tokyo, Japan

    5 shared publications
  • Ichiro Seto

    Department of Radiation Oncology, Southern Tohoku BNCT Research Center , 7-10 Yatsuyamada, Koriyama-shi, Fukushima 963-8052

    5 shared publications
  • Masanori Machida

    Department of Radiation Oncology, Southern TOHOKU General Hospital, Koriyama, Fukushima, Japan

    5 shared publications

Latest Publications

  • Open Access

    The feasibility and toxicity of the second course of boron neutron capture therapy in recurrent head and neck cancer patients

    by Yoshiaki Takagawa, Yoshihiro Takai, Takashi Ono, Ichiro Seto, Kanako Takayama, Shinya Komori, Ryohei Kato, Akihiko Takeuchi, Yuhei Yamazaki, Tomoaki Motoyanagi, et al.

    The feasibility and safety of a second course of boron neutron capture therapy (BNCT) are unknown. In this study, we retrospectively analyzed the treatment outcomes and toxicities in recurrent head and neck cancer (RHNC) patients who underwent BNCT twice at Southern TOHOKU BNCT Research Center. In total, 33 patients who underwent BNCT twice for RHNC at Southern TOHOKU BNCT Research Center between June 2020 and March 2024 were included. The indications for second BNCT were local recurrence or residual tumor after the first course. Eligible patients either declined salvage surgery or had no curative treatment options other than second BNCT. The median age was 65 years (range, 23–84 years), and the median interval from the first to the second BNCT was 4.1 months (range, 2.3–14.2 months). The median follow-up period after second BNCT was 27.3 months (range, 3.8–60.4 months), and the median survival time after second BNCT was 33.6 months. The 1-year/2-year overall survival and local control after second BNCT were 81.8%/57.1% and 38.3%/22.3%, respectively. The response rates to the first and second courses of BNCT were 81.8% and 70%, respectively. Acute and late Grade 3 or higher toxicities were observed in 5 (15.1%) and 20 patients (60.6%), respectively. Only one patient developed Grade 5 aspiration pneumonia. A second course of BNCT developed a high incidence of late Grade 3 or higher toxicities with limited clinical benefit. Therefore, it may be considered only in carefully selected patients without alternative treatment options.

  • Open Access

    Proton beam therapy for external auditory canal and middle ear cancers

    by Masanori Machida, Takashi Ono, Koki Ando, Rei Nishikawa, Yuntao Dai, Takuya Tominaga, Yusuke Azami, Yoshiaki Takagawa, Motohisa Suzuki, Ichiro Seto, et al.

    Few studies have evaluated the efficacy of proton beam therapy (PBT) for external auditory canal cancer (EACC) or middle ear cancer (MEC). Therefore, the present study aimed to evaluate the efficacy and toxicity of PBT for EACC and MEC. Between December 2009 and August 2018, 15 patients (seven males and eight females) underwent PBT for EACC or MEC. The median patient age was 64 years (range: 40–82 years). Ten patients had EACC, and five patients had MEC. PBT was administered using the passive scattering method. The median total dose of the BED10 was 88.8 Gy relative biological effectiveness (RBE) (range = 85.6–99.3 Gy [RBE]), administered in 2 Gy fractions (EQD2) (α/β = 10). Chemotherapy was conducted in 14 patients, systemic chemotherapy in five and intra-arterial infusion chemotherapy in nine. The median follow-up period for all patients was 60 months (range: 7–136 months). The 3-year overall survival, local control and progression free survival rates were 65%, 66.7% and 53.3%, respectively. Four patients had grade 3 hearing impairment owing to late toxicity. However, these patients had hearing impairment before treatment as well. No grade 4 or higher late toxicity was observed during the follow-up period. PBT is an effective treatment for EACC and MEC with tolerable toxicity, including in the setting of combined chemotherapy.

  • A novel dose-based intra-preplan method for high-dose-rate brachytherapy in cervical cancer using modeling and optimization algorithms

    by Shinya Komori, Yoshiaki Takagawa, Hiroki Sato, Masanori Machida, Masato Kato, Hisao Ouchi, Hiromitsu Endo, Wataru Itano, Takahiro Kato


  • Efficient workflow and clinical validation of in-house 3D-printed vaginal cylinders for high-dose-rate brachytherapy for gynecologic malignancies

    by Shinya Komori, Yoshiaki Takagawa, Akihiko Takeuchi, Hiroki Sato, Takahiro Kato

    This study developed an efficient methodology for in-house 3D-printed vaginal cylinders for gynecologic tumor treatment by evaluating their radiation attenuation, geometric accuracy, and efficacy. Ultimately, we aim to establish a simple, cost-effective approach that facilitates broad clinical adoption. Patient-specific vaginal cylinders were designed based on anatomical contours from the treatment planning system (TPS) using CAD software. The process was optimized to minimize manpower and time costs. Radiation attenuation of the 3D printer material was compared with that of water using the Monte Carlo method. Geometric accuracy was automatically analyzed via an in-house MATLAB program. Efficacy was assessed in cases of postoperative vaginal stump recurrence and vaginal cancer with paravaginal invasion. The tumor shape, delineated by TPS, was imported into CAD software, and the catheter pathway model, designed via subtraction processing, was placed at the optimal position and angle. The design process took approximately 15 min, and the entire workflow was completed within a week, demonstrating its practicality for clinical use. The radiation attenuation error was < 3% compared with water, and the geometric accuracy error was < 0.2 mm. The patient-specific vaginal cylinder provided a favorable dose distribution and was effective in complex cases. A feasible workflow was established, allowing in-house design and manufacturing with reduced manpower and time costs. With no material or processing issues, this approach is safe, practical, and promising for widespread adoption in personalized brachytherapy.

  • Analysis of operative duration of image-guided brachytherapy for cervical cancer

    by Yoshiaki Takagawa, Masanori Machida, Ichiro Seto, Shinya Komori, Hiroki Sato, Hiromitsu Endo, Hiroko Midorikawa, Takahiro Kato, Masao Murakami, Michitaka Honda, et al.

    Purpose The present study aimed to analyze the operative duration of image-guided brachytherapy (IGBT) for cervical cancer performed at our institution. Methods We enrolled cervical cancer patients who had undergone tandem and ovoid-based intracavitary brachytherapy (ICBT) or intracavitary and interstitial brachytherapy (IC/ISBT) between 2020 and 2024. Cone beam computed tomography (CBCT), CT, or CT + MRI were used for IGBT. For each IGBT session, we retrospectively reviewed the following: application time (AT—defined as the duration from entry into the operating room to the initial image acquisition); planning time (PT—defined as the duration from the initial image acquisition to the start of irradiation); and total operation time (TOT— defined as the duration from entry to exit of the operating room). Results We analyzed a total of 126 sessions in 36 patients, consisting of 99 ICBT-only sessions and 27 IC/ISBT sessions. The IC/ISBT sessions had a significantly longer mean operative duration than the ICBT-only sessions. The IC/ISBT sessions with three or more interstitial needles had significantly longer AT and TOT. However, the IC/ISBT sessions with one needle showed no significant difference in operative duration compared to ICBT-only sessions. CBCT, CT, and CT + MRI were used in 42, 76, and 8 sessions, respectively. In the ICBT patients, CT + MRI had the longest PT. However, there was no significant differences in TOT among CBCT, CT, and CT + MRI. Conclusions IC/ISBT sessions with one needle had no significant difference in operative duration compared to ICBT-only sessions. There was no significant difference in TOT between CT + MRI-based IGBT and CT-based IGBT.


  • Open Access

    Clinical Outcomes of Proton Beam Therapy for Unresectable Locally Advanced Pancreatic Cancer: A Single-Center Retrospective Study

    by Ichiro Seto, Hisashi Yamaguchi, Yoshiaki Takagawa, Yusuke Azami, Kanako Takayama, Motohisa Suzuki, Masanori Machida, Yuntao Dai, Nor Shazrina Binti Sulaiman, Yasuhiro Kikuchi, et al.


  • Open Access

    Interstitial round needles should not be used for cervical cancer patient treated with intracavitary/ interstitial brachytherapy using a Venezia applicator : a case report

    by Yoshiaki Takagawa, Sachiko Izumi, Eiichi Takahashi, Midori Kita

    Image-guided adaptive brachytherapy (IGABT) demonstrates an excellent local control rate and low toxicity while treating cervical cancer. For intracavitary/interstitial (IC/IS) brachytherapy (BT), several applicators are commercially available. Venezia (Elekta, Sweden), an advanced gynecological applicator, is designed for IC/IS BT for treating locally advanced cervical cancer. There are two types of interstitial needles for the Venezia applicator: the round needle and sharp needle. Generally, a round needle is safer because it has less risk of damaging the organ at risk than a sharp needle. However, there is currently no evidence to suggest that a round needle is better than a sharp needle for the Venezia applicator in IC/IS BT. Herein, we documented our experience of using both round and sharp needles with the Venezia applicator in IC/IS BT for cervical cancer. A 71-year-old woman was diagnosed with clinical stage T2bN0M0 and the International Federation of Gynecology and Obstetrics stage IIB cervical squamous cell carcinoma. Definitive therapy, including a high-dose-rate BT boost, was planned using a round needle with the Venezia applicator in IC/IS BT. After inserting four interstitial round needles during the first and second BT sessions, an unexpectedly large gap (1.5 cm) was detected between the cervix and ovoid. We therefore used a sharp needle with the Venezia applicator for IC/IS BT during the third and fourth BT sessions. Three sharp needles were firmly inserted during the third and fourth BT sessions. The study findings suggest that the interstitial round needle should not be used for cervical cancer patients undergoing IC/IS BT using the Venezia applicator.

  • Open Access

    Proton beam reirradiation for locally recurrent rectal cancer patients with prior pelvic irradiation

    by Yoshiaki Takagawa, Motohisa Suzuki, Ichiro Seto, Yusuke Azami, Masanori Machida, Kanako Takayama, Nor Shazrina Sulaiman, Tatsuhiko Nakasato, Yasuhiro Kikuchi, Masao Murakami, et al.

    The aim of the present study was to report the feasibility of proton beam reirradiation for patients with locally recurrent rectal cancer (LRRC) with prior pelvic irradiation. The study population included patients who were treated with proton beam therapy (PBT) for LRRC between 2008 and December 2019 in our institution. Those who had a history of distant metastases of LRRC, with or without treatment, before reirradiation, were excluded. Overall survival (OS), progression-free survival (PFS) and local control (LC) were estimated using the Kaplan–Meier method. Ten patients were included in the present study. The median follow-up period was 28.7 months, and the median total dose of prior radiotherapy (RT) was 50 Gy (range, 30 Gy–74.8 Gy). The median time from prior RT to reirradiation was 31.5 months (range, 8.1–96.6 months), and the median reirradiation dose was 72 Gy (relative biological effectiveness) (range, 56–77 Gy). The 1-year/2-year OS, PFS and LC rates were 100%/60.0%, 20.0%/10.0% and 70.0%/58.3%, respectively, with a median survival time of 26.0 months. Seven patients developed a Grade 1 acute radiation dermatitis, and no Grade ≥ 2 acute toxicity was recorded. Grade ≥ 3 late toxicity was recorded in only one patient, who had developed a colostomy due to radiation-related intestinal bleeding. Reirradiation using PBT for LRRC patients who had previously undergone pelvic irradiation was feasible. However, the indications for PBT reirradiation for LRRC patients need to be considered carefully due to the risk of severe late GI toxicity.


  • Open Access

    Outcomes and Prognostic Factors for Locally Recurrent Rectal Cancer Treated With Proton Beam Therapy

    by Yoshiaki Takagawa, Motohisa Suzuki, Hisashi Yamaguchi, Ichiro Seto, Yusuke Azami, Masanori Machida, Kanako Takayama, Takuya Tominaga, Masao Murakami


  • Open Access

    Proton Beam Therapy With Space-Making Surgery (Omental Plombage) for Oligorecurrent Liver Metastasis of Esophageal Adenocarcinoma

    by Yojiro Ishikawa, Koji Morita, Hisashi Yamaguchi, Takahiro Kato, Motohisa Suzuki, Ichiro Seto, Masanori Machida, Kanako Takayama, Takuya Tominaga, Yoshiaki Takagawa, et al.

    Proton beam therapy (PBT) with space-making surgery has been used recently; however, its effectiveness for recurrent esophageal cancer (EC) is unclear. We herein report an unusual case of successful PBT with space-making surgery (omental plombage) for recurrent liver metastasis after EC surgery. A 58-year-old Japanese man underwent proximal gastrectomy for esophagogastric (EG) junction cancer seven months before presentation to our hospital. Microscopic findings after the surgery showed that the tumor was adenocarcinoma of the EG junction (pT1N0M0, stage I). Seven months after the proximal gastrectomy, liver metastases in S6 and S8 were revealed by positron emission tomography-computed tomography. Initial PBT was performed for those two liver metastases, and complete response (CR) was obtained for both liver metastases. Recurrence of liver metastasis in S2 was found eight months after the first PBT, and CR was achieved by chemotherapy. However, new liver metastasis recurred in S2. Considering the effects of radiation exposure on the surrounding gastrointestinal organs, we performed space-making surgery to place the omentum around the liver metastasis. We were able to complete the second PBT for the liver metastasis with 72.6 Gy relative biological effectiveness in 22 fractions. After the second PBT, the patient survived for seven years without recurrence. PBT with space-making surgery (omental plombage) for recurrent liver metastasis after EC surgery is considered to be a therapeutic option.