Florian Dietrich
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Florian Dietrich has a total of 206 co-authors. Here are the top co-authors by number of shared publications:
- Jia Chen
Technical University of Munich (Munich, Germany)
61 shared publications Frank Hase
28 shared publications- Adrian Wenzel
Environmental Sensing and Modeling, Technical University of Munich (TUM), Munich, Germany
16 shared publications - Xinxu Zhao
Electrical and Computer Engineering, Technische Unversität München, 80333 Munich, Germany
16 shared publications - Matthias Frey
National Institute for Environmental Studies, Tsukuba, Japan
12 shared publications Andreas Forstmaier
Environmental Sensing and Modeling, Technical University of Munich (TUM), Munich, Germany
10 shared publications
Latest Publications
- Open Access
- 21 May 2025
- Published by Copernicus GmbH
Observational and Modeling Tools for Monitoring Urban Greenhouse Gas Emissions: Results of the ICOS Pilot City Munich
Cities are hotspots for anthropogenic greenhouse gas (GHG) emissions and, therefore, play an essential role in mitigating climate change. It is crucial to accurately monitor urban GHG emissions to track the reduction targets that many cities have set. The ICOS Cities project aims to pioneer GHG measurement methodologies. Munich, along with Zurich and Paris, serves as one of the pilot cities for this project. Here, we present key results of the ICOS Cities project for Munich.We developed a multi-scale sensor network in Munich, including five solar-tracking spectrometers (MUCCnet) for total column CO2, CH4, and CO measurements, 20 mid-cost CO2 sensor systems, 99 low-cost CO2 sensors, and 30 low-cost air quality sensor systems on rooftops and streetlamps. A mobile measurement unit, consisting of an e-bike carrying a high-precision instrument, is used to find emission hotspots in the city. In addition, CO2 and CH4 satellites specifically target Munich to enable a comparative analysis with MUCCnet.To achieve a high-resolution and accurate emission estimate for Munich, we also developed (i) an emission inventory with high spatial and temporal resolution (100m, hourly) for the road traffic, heating, public power, and human respiration sectors; (ii) a microscale transport model (10m, hourly) based on GRAMM/GRAL simulations; and (iii) a high-resolution biosphere model (10m, hourly) based on VPRM using a self-developed vegetation land cover (1m) and Sentinel-2 satellite vegetation indices.Combining these fundamental components, we performed inverse modeling to assess the emissions in Munich for more than five years. We compared the performances of inverse modeling algorithms using different background approaches, transport models, and prior emissions. Changes due to interventions and policies, e.g., COVID lockdown and energy transition, can be observed in the emission assessments. We present measurement-based emission trends determined by our observations and modeling tools, and provide recommendations on monitoring strategies for other cities.
- 21 May 2025
- Published by Copernicus GmbH
Open AccessObservational and Modeling Tools for Monitoring Urban Greenhouse Gas Emissions: Results of the ICOS Pilot City Munich
Cities are hotspots for anthropogenic greenhouse gas (GHG) emissions and, therefore, play an essential role in mitigating climate change. It is crucial to accurately monitor urban GHG emissions to track the reduction targets that many cities have set. The ICOS Cities project aims to pioneer GHG measurement methodologies. Munich, along with Zurich and Paris, serves as one of the pilot cities for this project. Here, we present key results of the ICOS Cities project for Munich.We developed a multi-scale sensor network in Munich, including five solar-tracking spectrometers (MUCCnet) for total column CO2, CH4, and CO measurements, 20 mid-cost CO2 sensor systems, 99 low-cost CO2 sensors, and 30 low-cost air quality sensor systems on rooftops and streetlamps. A mobile measurement unit, consisting of an e-bike carrying a high-precision instrument, is used to find emission hotspots in the city. In addition, CO2 and CH4 satellites specifically target Munich to enable a comparative analysis with MUCCnet.To achieve a high-resolution and accurate emission estimate for Munich, we also developed (i) an emission inventory with high spatial and temporal resolution (100m, hourly) for the road traffic, heating, public power, and human respiration sectors; (ii) a microscale transport model (10m, hourly) based on GRAMM/GRAL simulations; and (iii) a high-resolution biosphere model (10m, hourly) based on VPRM using a self-developed vegetation land cover (1m) and Sentinel-2 satellite vegetation indices.Combining these fundamental components, we performed inverse modeling to assess the emissions in Munich for more than five years. We compared the performances of inverse modeling algorithms using different background approaches, transport models, and prior emissions. Changes due to interventions and policies, e.g., COVID lockdown and energy transition, can be observed in the emission assessments. We present measurement-based emission trends determined by our observations and modeling tools, and provide recommendations on monitoring strategies for other cities.
- Open Access
- 20 January 2025
- Published by Copernicus GmbH
Using a portable EM27/SUN FTIR-spectrometer for validating the TCCON site-to-site consistency: The COCCON Travel Standard
The precise knowledge of the global atmospheric concentrations of green-house gases (GHG) are crucial for understanding and monitoring climate change.Satellites for measuring GHGs are offering a global coverage, however, they need precise ground-based reference data for validation.This reference data is provided by ground-based measurements, foremost the Total Column Carbon Observing Network (TCCON).The TCCON measures column averages of GHG abundances at about 25 stations around the globe using Fourier Transform Infrared (FTIR) spectrometer.For achieving the high data quality needed for the validation of current and upcoming GHG measuring satellite missions the control of site-by-site biases across the network is of utmost importance. So far, the verification of the individual TCCON sites mainly depends on the collection of collocated in situ measurements of GHG profiles, using airplane overflights or balloon air-core measurements, the use of calibrated HCl gas cells and on the evaluation of XAIR. In this work we present a new supplemental approach by using the portable EM27/SUN FTIR spectrometer, which is the standard instrument of the Collaborative Carbon Column Observing Network (COCCON). This instrument type has proven its high stability in various field campaigns and long-term studies. In the framework of the ESA project “Fiducial Reference Measurements for Green-House Gases II” we are exploiting the stability of the instrument to use it as a Travel Standard (TS) for the TCCON. We visited sites in Japan, Canada, Germany, Australia, France and the Canary Islands to perform side-by-side measurements with the local TCCON spectrometers. Between the visits, the stability of the TS was monitored using the Karlsruhe TCCON site and the COCCON reference spectrometer.This allows to compare the different TCCON sites to a common reference and hence, to verify the level of station-to-station consistency currently achieved by the TCCON and support further improvements. Here, we present the results of the TS visit at the TCCON site Tsukuba(Japan), Wollongong(Australia) and Izana(Canary Islands).
- 20 January 2025
- Published by Copernicus GmbH
Open AccessUsing a portable EM27/SUN FTIR-spectrometer for validating the TCCON site-to-site consistency: The COCCON Travel Standard
The precise knowledge of the global atmospheric concentrations of green-house gases (GHG) are crucial for understanding and monitoring climate change.Satellites for measuring GHGs are offering a global coverage, however, they need precise ground-based reference data for validation.This reference data is provided by ground-based measurements, foremost the Total Column Carbon Observing Network (TCCON).The TCCON measures column averages of GHG abundances at about 25 stations around the globe using Fourier Transform Infrared (FTIR) spectrometer.For achieving the high data quality needed for the validation of current and upcoming GHG measuring satellite missions the control of site-by-site biases across the network is of utmost importance. So far, the verification of the individual TCCON sites mainly depends on the collection of collocated in situ measurements of GHG profiles, using airplane overflights or balloon air-core measurements, the use of calibrated HCl gas cells and on the evaluation of XAIR. In this work we present a new supplemental approach by using the portable EM27/SUN FTIR spectrometer, which is the standard instrument of the Collaborative Carbon Column Observing Network (COCCON). This instrument type has proven its high stability in various field campaigns and long-term studies. In the framework of the ESA project “Fiducial Reference Measurements for Green-House Gases II” we are exploiting the stability of the instrument to use it as a Travel Standard (TS) for the TCCON. We visited sites in Japan, Canada, Germany, Australia, France and the Canary Islands to perform side-by-side measurements with the local TCCON spectrometers. Between the visits, the stability of the TS was monitored using the Karlsruhe TCCON site and the COCCON reference spectrometer.This allows to compare the different TCCON sites to a common reference and hence, to verify the level of station-to-station consistency currently achieved by the TCCON and support further improvements. Here, we present the results of the TS visit at the TCCON site Tsukuba(Japan), Wollongong(Australia) and Izana(Canary Islands).
- Open Access
- 30 September 2024
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 17 (19) , 5679-5707
Greenhouse gas column observations from a portable spectrometer in Uganda
The extensive terrestrial ecosystems of tropical Africa are a significant store of carbon and play a key but uncertain role in the atmospheric budgets of carbon dioxide and methane. As ground-based observations in the tropics are scarce compared with other parts of the world, recent studies have instead made use of satellite observations assimilated into atmospheric chemistry and transport models to conclude that methane emissions from this geographical region have increased since 2010 as a result of increased wetland extent, accounting for up to a third of global methane growth, and that the tropical Africa region dominates net carbon emission across the tropics. These studies critically rely on the accuracy of satellite datasets, such as those from the Orbiting Carbon Observatory-2 (OCO-2), the Greenhouse gases Observing SATellite (GOSAT), and the Sentinel-5 Precursor TROPOspheric Monitoring Instrument (TROPOMI), along with results from atmospheric transport models, over a geographical region where there are little independent data to test the robustness of published results. In this paper we present the first ground-based observations of greenhouse gas column concentrations over East Africa, obtained using a portable Bruker EM27/SUN Fourier transform infrared (FTIR) spectrometer during a deployment covering the first few months of 2020 in Jinja, Uganda. We operated the instrument near autonomously by way of an automated weatherproof enclosure and observed total atmospheric column concentrations of the greenhouse gases carbon dioxide and methane, as well as carbon monoxide, a useful proxy for emissions from incomplete combustion processes in the region. We discuss the performance of the combined enclosure and spectrometer system that we deployed in Jinja to obtain these data and show comparisons of our ground-based observations with satellite datasets from OCO-2 and Orbiting Carbon Observatory-3 (OCO-3) for carbon dioxide and TROPOMI for methane and carbon monoxide, whilst also comparing our results with concentration data from the GEOS-Chem and Copernicus Atmosphere Monitoring Service (CAMS) atmospheric inversions that provide a means of increasing spatial and temporal coverage where satellite data are not available. For our measurement period, we find mean differences in between OCO-2 and the EM27/SUN of −0.29 % and between OCO-3 and the EM27/SUN of −0.28 %. In the case of TROPOMI, the mean difference in that we find between TROPOMI and the EM27/SUN is −0.44 %, whilst for XCO the mean difference is −5.65 %. In each of these cases, the mean difference observed between the satellite and ground-based column concentrations is either close to or within the precision and accuracy requirements for the respective missions. With regard to the model and reanalysis comparisons with the EM27/SUN column concentrations, we see mean differences from the EM27/SUN of a global GEOS-Chem inversion for of −0.08 %, a regional high-resolution GEOS-Chem inversion for of −0.22 %, and the CAMS global reanalysis for XCO of −9.79 %. Our results demonstrate the value of ground-based observations of total column concentrations and show that the combined EM27/SUN and enclosure system employed would be suitable for acquisition of the longer-term observations needed to rigorously evaluate satellite observations and model and reanalysis calculations over tropical Africa.- 30 September 2024
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 17 (19) , 5679-5707
Open AccessGreenhouse gas column observations from a portable spectrometer in Uganda
The extensive terrestrial ecosystems of tropical Africa are a significant store of carbon and play a key but uncertain role in the atmospheric budgets of carbon dioxide and methane. As ground-based observations in the tropics are scarce compared with other parts of the world, recent studies have instead made use of satellite observations assimilated into atmospheric chemistry and transport models to conclude that methane emissions from this geographical region have increased since 2010 as a result of increased wetland extent, accounting for up to a third of global methane growth, and that the tropical Africa region dominates net carbon emission across the tropics. These studies critically rely on the accuracy of satellite datasets, such as those from the Orbiting Carbon Observatory-2 (OCO-2), the Greenhouse gases Observing SATellite (GOSAT), and the Sentinel-5 Precursor TROPOspheric Monitoring Instrument (TROPOMI), along with results from atmospheric transport models, over a geographical region where there are little independent data to test the robustness of published results. In this paper we present the first ground-based observations of greenhouse gas column concentrations over East Africa, obtained using a portable Bruker EM27/SUN Fourier transform infrared (FTIR) spectrometer during a deployment covering the first few months of 2020 in Jinja, Uganda. We operated the instrument near autonomously by way of an automated weatherproof enclosure and observed total atmospheric column concentrations of the greenhouse gases carbon dioxide and methane, as well as carbon monoxide, a useful proxy for emissions from incomplete combustion processes in the region. We discuss the performance of the combined enclosure and spectrometer system that we deployed in Jinja to obtain these data and show comparisons of our ground-based observations with satellite datasets from OCO-2 and Orbiting Carbon Observatory-3 (OCO-3) for carbon dioxide and TROPOMI for methane and carbon monoxide, whilst also comparing our results with concentration data from the GEOS-Chem and Copernicus Atmosphere Monitoring Service (CAMS) atmospheric inversions that provide a means of increasing spatial and temporal coverage where satellite data are not available. For our measurement period, we find mean differences in between OCO-2 and the EM27/SUN of −0.29 % and between OCO-3 and the EM27/SUN of −0.28 %. In the case of TROPOMI, the mean difference in that we find between TROPOMI and the EM27/SUN is −0.44 %, whilst for XCO the mean difference is −5.65 %. In each of these cases, the mean difference observed between the satellite and ground-based column concentrations is either close to or within the precision and accuracy requirements for the respective missions. With regard to the model and reanalysis comparisons with the EM27/SUN column concentrations, we see mean differences from the EM27/SUN of a global GEOS-Chem inversion for of −0.08 %, a regional high-resolution GEOS-Chem inversion for of −0.22 %, and the CAMS global reanalysis for XCO of −9.79 %. Our results demonstrate the value of ground-based observations of total column concentrations and show that the combined EM27/SUN and enclosure system employed would be suitable for acquisition of the longer-term observations needed to rigorously evaluate satellite observations and model and reanalysis calculations over tropical Africa. - Open Access
- 5 June 2024
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 17 (11) , 3467-3494
Using a portable FTIR spectrometer to evaluate the consistency of Total Carbon Column Observing Network (TCCON) measurements on a global scale: the Collaborative Carbon Column Observing Network (COCCON) travel standard
To fight climate change, it is crucial to have a precise knowledge of greenhouse gas (GHG) concentrations in the atmosphere and to monitor sources and sinks of GHGs. On global scales, satellites are an appropriate monitoring tool. For the validation of the satellite measurements and to tie them to the World Meteorological Organization (WMO) trace gas scale, ground-based Fourier transform infrared (FTIR) networks are used, which provide reference data. To ensure the highest-quality validation data, the network must be scaled to the WMO trace gas scale and have a very small site-to-site bias. Currently, the Total Carbon Column Observing Network (TCCON) is the de facto standard FTIR network for providing reference data. Ensuring a small site-to-site bias is a major challenge for the TCCON. In this work, we describe the development and application of a new method to evaluate the site-to-site bias by using a remotely controlled portable FTIR spectrometer as a travel standard (TS) for evaluating the consistency of columnar GHG measurements performed at different TCCON stations, and we describe campaign results for the TCCON sites in Tsukuba (Japan), East Trout Lake (Canada) and Wollongong (Australia). The TS is based on a characterized portable EM27/SUN FTIR spectrometer equipped with an accurate pressure sensor which is operated in an automated enclosure. The EM27/SUN is the standard instrument of the Collaborative Carbon Column Observing Network (COCCON). The COCCON is designed such that all spectrometers are referenced to a common reference unit located in Karlsruhe, Germany. To evaluate the long-term stability of the TS instrument, it is placed side-by-side with the TCCON instrument in Karlsruhe (KA) and the COCCON reference unit (the EM27/SUN spectrometer SN37, which is operated permanently next to the TCCON-KA site) between deployments to collect comparing measurements. At each of the visited TCCON sites, the TCCON spectrometers collected low-resolution (LR) (0.5 cm−1) and high-resolution (HR) (0.02 cm−1) measurements in an alternating manner. Based on the TS as a portable standard, the measurements are compared to the Karlsruhe site as a common reference. For Tsukuba and Wollongong, the agreement with the reference in Karlsruhe found for XCO2 is on the 0.1 % level for both the LR and HR measurements. For XCH4, the agreement is at the 0.2 % level, with the low-resolution measurements showing a low bias at both sites and for both gases. For XCO, the deviations are up to 7 %. The reason for this is likely to be a known issue with the CO a priori profiles used by the TCCON over source regions. In East Trout Lake (ETL), the TCCON spectrometer broke down while the TS was en route to the station. Hence, no side-by-side comparison was possible there. An important auxiliary value for FTIR retrievals is the surface pressure. Using the pressure sensor in the TS, the surface pressure measurements at each site are also compared. The surface pressure analysis reveals excellent agreement (0.027, 0.135 and 0.094 hPa) for the Tsukuba, ETL and Wollongong sites.
- 5 June 2024
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 17 (11) , 3467-3494
Open AccessUsing a portable FTIR spectrometer to evaluate the consistency of Total Carbon Column Observing Network (TCCON) measurements on a global scale: the Collaborative Carbon Column Observing Network (COCCON) travel standard
To fight climate change, it is crucial to have a precise knowledge of greenhouse gas (GHG) concentrations in the atmosphere and to monitor sources and sinks of GHGs. On global scales, satellites are an appropriate monitoring tool. For the validation of the satellite measurements and to tie them to the World Meteorological Organization (WMO) trace gas scale, ground-based Fourier transform infrared (FTIR) networks are used, which provide reference data. To ensure the highest-quality validation data, the network must be scaled to the WMO trace gas scale and have a very small site-to-site bias. Currently, the Total Carbon Column Observing Network (TCCON) is the de facto standard FTIR network for providing reference data. Ensuring a small site-to-site bias is a major challenge for the TCCON. In this work, we describe the development and application of a new method to evaluate the site-to-site bias by using a remotely controlled portable FTIR spectrometer as a travel standard (TS) for evaluating the consistency of columnar GHG measurements performed at different TCCON stations, and we describe campaign results for the TCCON sites in Tsukuba (Japan), East Trout Lake (Canada) and Wollongong (Australia). The TS is based on a characterized portable EM27/SUN FTIR spectrometer equipped with an accurate pressure sensor which is operated in an automated enclosure. The EM27/SUN is the standard instrument of the Collaborative Carbon Column Observing Network (COCCON). The COCCON is designed such that all spectrometers are referenced to a common reference unit located in Karlsruhe, Germany. To evaluate the long-term stability of the TS instrument, it is placed side-by-side with the TCCON instrument in Karlsruhe (KA) and the COCCON reference unit (the EM27/SUN spectrometer SN37, which is operated permanently next to the TCCON-KA site) between deployments to collect comparing measurements. At each of the visited TCCON sites, the TCCON spectrometers collected low-resolution (LR) (0.5 cm−1) and high-resolution (HR) (0.02 cm−1) measurements in an alternating manner. Based on the TS as a portable standard, the measurements are compared to the Karlsruhe site as a common reference. For Tsukuba and Wollongong, the agreement with the reference in Karlsruhe found for XCO2 is on the 0.1 % level for both the LR and HR measurements. For XCH4, the agreement is at the 0.2 % level, with the low-resolution measurements showing a low bias at both sites and for both gases. For XCO, the deviations are up to 7 %. The reason for this is likely to be a known issue with the CO a priori profiles used by the TCCON over source regions. In East Trout Lake (ETL), the TCCON spectrometer broke down while the TS was en route to the station. Hence, no side-by-side comparison was possible there. An important auxiliary value for FTIR retrievals is the surface pressure. Using the pressure sensor in the TS, the surface pressure measurements at each site are also compared. The surface pressure analysis reveals excellent agreement (0.027, 0.135 and 0.094 hPa) for the Tsukuba, ETL and Wollongong sites.
- Open Access
- 27 March 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-46
Reply on RC2
To fight climate change it is crucial to have a precise knowledge of Greenhouse Gas (GHG) concentrations in the atmosphere and to monitor sources and sinks of GHGs. On global scales, satellites are an appropriate monitoring tool. For the validation of the satellite measurements, and to tie them to the World Meteorological Organization (WMO) trace gas scale, ground based Fourier Transform Infrared (FTIR) networks are used, which provide reference data. To ensure the highest quality validation data, the network must be scaled to the WMO trace gas scale and have a very small site-to-site bias. Currently, the Total Carbon Column Observing Network (TCCON) is the de-facto standard FTIR network for providing reference data. To ensure a small site-to-site bias is a major challenge for the TCCON. In this work we describe the development and application of a new method to evaluate the site-to-site bias by using a remotely controlled portable FTIR spectrometer as a Travel Standard (TS) for evaluating the consistency of columnar GHG measurements performed at different TCCON stations and we describe campaign results for the TCCON sites in Tsukuba (Japan), East Trout Lake (Canada) and Wollongong (Australia). The TS is based on a characterized portable EM27/SUN FTIR spectrometer equipped with an accurate pressure sensor which is operated in an automated enclosure. The EM27/SUN is the standard instrument of the Collaborative Carbon Column Observing Network (COCCON). The COCCON is designed such that all spectrometers are referenced to a common reference unit located in Karlsruhe, Germany. To evaluate the long-term stability of the TS instrument, it is placed side-by-side with the TCCON instrument in Karlsruhe and the COCCON reference unit (the EM27/SUN spectrometer SN37, which is operated permanently next to the TCCON-KA site) between deployments to collect comparing measurements. At each of the visited TCCON sites, the TCCON spectrometers collected low-resolution (LR) (0.5 cm-1) and high-resolution (HR) (0.02 cm-1) measurements in an alternating manner. In East Trout Lake (ETL), the TCCON spectrometer broke down while the TS was en route to the station. Hence, no side-by-side comparison was possible there. For Tsukuba and Wollongong the agreement found for XCO2 is on the 0.1 % level. For XCH4 the agreement is at the 0.2 % level, with the low-resolution measurements showing a low bias at both sites and for both gases. For XCO the deviations are up to 7 %. The reason for this is likely to be an known issue with the CO a priori profiles used by TCCON over source regions. The pressure analysis reveals excellent agreement (0.027 hPa, 0.135 hPa, and 0.094 hPa) for the Tsukuba, ETL, and Wollongong sites.
- 27 March 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-46
Open AccessReply on RC2
To fight climate change it is crucial to have a precise knowledge of Greenhouse Gas (GHG) concentrations in the atmosphere and to monitor sources and sinks of GHGs. On global scales, satellites are an appropriate monitoring tool. For the validation of the satellite measurements, and to tie them to the World Meteorological Organization (WMO) trace gas scale, ground based Fourier Transform Infrared (FTIR) networks are used, which provide reference data. To ensure the highest quality validation data, the network must be scaled to the WMO trace gas scale and have a very small site-to-site bias. Currently, the Total Carbon Column Observing Network (TCCON) is the de-facto standard FTIR network for providing reference data. To ensure a small site-to-site bias is a major challenge for the TCCON. In this work we describe the development and application of a new method to evaluate the site-to-site bias by using a remotely controlled portable FTIR spectrometer as a Travel Standard (TS) for evaluating the consistency of columnar GHG measurements performed at different TCCON stations and we describe campaign results for the TCCON sites in Tsukuba (Japan), East Trout Lake (Canada) and Wollongong (Australia). The TS is based on a characterized portable EM27/SUN FTIR spectrometer equipped with an accurate pressure sensor which is operated in an automated enclosure. The EM27/SUN is the standard instrument of the Collaborative Carbon Column Observing Network (COCCON). The COCCON is designed such that all spectrometers are referenced to a common reference unit located in Karlsruhe, Germany. To evaluate the long-term stability of the TS instrument, it is placed side-by-side with the TCCON instrument in Karlsruhe and the COCCON reference unit (the EM27/SUN spectrometer SN37, which is operated permanently next to the TCCON-KA site) between deployments to collect comparing measurements. At each of the visited TCCON sites, the TCCON spectrometers collected low-resolution (LR) (0.5 cm-1) and high-resolution (HR) (0.02 cm-1) measurements in an alternating manner. In East Trout Lake (ETL), the TCCON spectrometer broke down while the TS was en route to the station. Hence, no side-by-side comparison was possible there. For Tsukuba and Wollongong the agreement found for XCO2 is on the 0.1 % level. For XCH4 the agreement is at the 0.2 % level, with the low-resolution measurements showing a low bias at both sites and for both gases. For XCO the deviations are up to 7 %. The reason for this is likely to be an known issue with the CO a priori profiles used by TCCON over source regions. The pressure analysis reveals excellent agreement (0.027 hPa, 0.135 hPa, and 0.094 hPa) for the Tsukuba, ETL, and Wollongong sites.
- Open Access
- 27 March 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-46
Reply on RC1
To fight climate change it is crucial to have a precise knowledge of Greenhouse Gas (GHG) concentrations in the atmosphere and to monitor sources and sinks of GHGs. On global scales, satellites are an appropriate monitoring tool. For the validation of the satellite measurements, and to tie them to the World Meteorological Organization (WMO) trace gas scale, ground based Fourier Transform Infrared (FTIR) networks are used, which provide reference data. To ensure the highest quality validation data, the network must be scaled to the WMO trace gas scale and have a very small site-to-site bias. Currently, the Total Carbon Column Observing Network (TCCON) is the de-facto standard FTIR network for providing reference data. To ensure a small site-to-site bias is a major challenge for the TCCON. In this work we describe the development and application of a new method to evaluate the site-to-site bias by using a remotely controlled portable FTIR spectrometer as a Travel Standard (TS) for evaluating the consistency of columnar GHG measurements performed at different TCCON stations and we describe campaign results for the TCCON sites in Tsukuba (Japan), East Trout Lake (Canada) and Wollongong (Australia). The TS is based on a characterized portable EM27/SUN FTIR spectrometer equipped with an accurate pressure sensor which is operated in an automated enclosure. The EM27/SUN is the standard instrument of the Collaborative Carbon Column Observing Network (COCCON). The COCCON is designed such that all spectrometers are referenced to a common reference unit located in Karlsruhe, Germany. To evaluate the long-term stability of the TS instrument, it is placed side-by-side with the TCCON instrument in Karlsruhe and the COCCON reference unit (the EM27/SUN spectrometer SN37, which is operated permanently next to the TCCON-KA site) between deployments to collect comparing measurements. At each of the visited TCCON sites, the TCCON spectrometers collected low-resolution (LR) (0.5 cm-1) and high-resolution (HR) (0.02 cm-1) measurements in an alternating manner. In East Trout Lake (ETL), the TCCON spectrometer broke down while the TS was en route to the station. Hence, no side-by-side comparison was possible there. For Tsukuba and Wollongong the agreement found for XCO2 is on the 0.1 % level. For XCH4 the agreement is at the 0.2 % level, with the low-resolution measurements showing a low bias at both sites and for both gases. For XCO the deviations are up to 7 %. The reason for this is likely to be an known issue with the CO a priori profiles used by TCCON over source regions. The pressure analysis reveals excellent agreement (0.027 hPa, 0.135 hPa, and 0.094 hPa) for the Tsukuba, ETL, and Wollongong sites.
- 27 March 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-46
Open AccessReply on RC1
To fight climate change it is crucial to have a precise knowledge of Greenhouse Gas (GHG) concentrations in the atmosphere and to monitor sources and sinks of GHGs. On global scales, satellites are an appropriate monitoring tool. For the validation of the satellite measurements, and to tie them to the World Meteorological Organization (WMO) trace gas scale, ground based Fourier Transform Infrared (FTIR) networks are used, which provide reference data. To ensure the highest quality validation data, the network must be scaled to the WMO trace gas scale and have a very small site-to-site bias. Currently, the Total Carbon Column Observing Network (TCCON) is the de-facto standard FTIR network for providing reference data. To ensure a small site-to-site bias is a major challenge for the TCCON. In this work we describe the development and application of a new method to evaluate the site-to-site bias by using a remotely controlled portable FTIR spectrometer as a Travel Standard (TS) for evaluating the consistency of columnar GHG measurements performed at different TCCON stations and we describe campaign results for the TCCON sites in Tsukuba (Japan), East Trout Lake (Canada) and Wollongong (Australia). The TS is based on a characterized portable EM27/SUN FTIR spectrometer equipped with an accurate pressure sensor which is operated in an automated enclosure. The EM27/SUN is the standard instrument of the Collaborative Carbon Column Observing Network (COCCON). The COCCON is designed such that all spectrometers are referenced to a common reference unit located in Karlsruhe, Germany. To evaluate the long-term stability of the TS instrument, it is placed side-by-side with the TCCON instrument in Karlsruhe and the COCCON reference unit (the EM27/SUN spectrometer SN37, which is operated permanently next to the TCCON-KA site) between deployments to collect comparing measurements. At each of the visited TCCON sites, the TCCON spectrometers collected low-resolution (LR) (0.5 cm-1) and high-resolution (HR) (0.02 cm-1) measurements in an alternating manner. In East Trout Lake (ETL), the TCCON spectrometer broke down while the TS was en route to the station. Hence, no side-by-side comparison was possible there. For Tsukuba and Wollongong the agreement found for XCO2 is on the 0.1 % level. For XCH4 the agreement is at the 0.2 % level, with the low-resolution measurements showing a low bias at both sites and for both gases. For XCO the deviations are up to 7 %. The reason for this is likely to be an known issue with the CO a priori profiles used by TCCON over source regions. The pressure analysis reveals excellent agreement (0.027 hPa, 0.135 hPa, and 0.094 hPa) for the Tsukuba, ETL, and Wollongong sites.
- Open Access
- 5 March 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-46
Comment on egusphere-2023-3089
To fight climate change it is crucial to have a precise knowledge of Greenhouse Gas (GHG) concentrations in the atmosphere and to monitor sources and sinks of GHGs. On global scales, satellites are an appropriate monitoring tool. For the validation of the satellite measurements, and to tie them to the World Meteorological Organization (WMO) trace gas scale, ground based Fourier Transform Infrared (FTIR) networks are used, which provide reference data. To ensure the highest quality validation data, the network must be scaled to the WMO trace gas scale and have a very small site-to-site bias. Currently, the Total Carbon Column Observing Network (TCCON) is the de-facto standard FTIR network for providing reference data. To ensure a small site-to-site bias is a major challenge for the TCCON. In this work we describe the development and application of a new method to evaluate the site-to-site bias by using a remotely controlled portable FTIR spectrometer as a Travel Standard (TS) for evaluating the consistency of columnar GHG measurements performed at different TCCON stations and we describe campaign results for the TCCON sites in Tsukuba (Japan), East Trout Lake (Canada) and Wollongong (Australia). The TS is based on a characterized portable EM27/SUN FTIR spectrometer equipped with an accurate pressure sensor which is operated in an automated enclosure. The EM27/SUN is the standard instrument of the Collaborative Carbon Column Observing Network (COCCON). The COCCON is designed such that all spectrometers are referenced to a common reference unit located in Karlsruhe, Germany. To evaluate the long-term stability of the TS instrument, it is placed side-by-side with the TCCON instrument in Karlsruhe and the COCCON reference unit (the EM27/SUN spectrometer SN37, which is operated permanently next to the TCCON-KA site) between deployments to collect comparing measurements. At each of the visited TCCON sites, the TCCON spectrometers collected low-resolution (LR) (0.5 cm-1) and high-resolution (HR) (0.02 cm-1) measurements in an alternating manner. In East Trout Lake (ETL), the TCCON spectrometer broke down while the TS was en route to the station. Hence, no side-by-side comparison was possible there. For Tsukuba and Wollongong the agreement found for XCO2 is on the 0.1 % level. For XCH4 the agreement is at the 0.2 % level, with the low-resolution measurements showing a low bias at both sites and for both gases. For XCO the deviations are up to 7 %. The reason for this is likely to be an known issue with the CO a priori profiles used by TCCON over source regions. The pressure analysis reveals excellent agreement (0.027 hPa, 0.135 hPa, and 0.094 hPa) for the Tsukuba, ETL, and Wollongong sites.
- 5 March 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-46
Open AccessComment on egusphere-2023-3089
To fight climate change it is crucial to have a precise knowledge of Greenhouse Gas (GHG) concentrations in the atmosphere and to monitor sources and sinks of GHGs. On global scales, satellites are an appropriate monitoring tool. For the validation of the satellite measurements, and to tie them to the World Meteorological Organization (WMO) trace gas scale, ground based Fourier Transform Infrared (FTIR) networks are used, which provide reference data. To ensure the highest quality validation data, the network must be scaled to the WMO trace gas scale and have a very small site-to-site bias. Currently, the Total Carbon Column Observing Network (TCCON) is the de-facto standard FTIR network for providing reference data. To ensure a small site-to-site bias is a major challenge for the TCCON. In this work we describe the development and application of a new method to evaluate the site-to-site bias by using a remotely controlled portable FTIR spectrometer as a Travel Standard (TS) for evaluating the consistency of columnar GHG measurements performed at different TCCON stations and we describe campaign results for the TCCON sites in Tsukuba (Japan), East Trout Lake (Canada) and Wollongong (Australia). The TS is based on a characterized portable EM27/SUN FTIR spectrometer equipped with an accurate pressure sensor which is operated in an automated enclosure. The EM27/SUN is the standard instrument of the Collaborative Carbon Column Observing Network (COCCON). The COCCON is designed such that all spectrometers are referenced to a common reference unit located in Karlsruhe, Germany. To evaluate the long-term stability of the TS instrument, it is placed side-by-side with the TCCON instrument in Karlsruhe and the COCCON reference unit (the EM27/SUN spectrometer SN37, which is operated permanently next to the TCCON-KA site) between deployments to collect comparing measurements. At each of the visited TCCON sites, the TCCON spectrometers collected low-resolution (LR) (0.5 cm-1) and high-resolution (HR) (0.02 cm-1) measurements in an alternating manner. In East Trout Lake (ETL), the TCCON spectrometer broke down while the TS was en route to the station. Hence, no side-by-side comparison was possible there. For Tsukuba and Wollongong the agreement found for XCO2 is on the 0.1 % level. For XCH4 the agreement is at the 0.2 % level, with the low-resolution measurements showing a low bias at both sites and for both gases. For XCO the deviations are up to 7 %. The reason for this is likely to be an known issue with the CO a priori profiles used by TCCON over source regions. The pressure analysis reveals excellent agreement (0.027 hPa, 0.135 hPa, and 0.094 hPa) for the Tsukuba, ETL, and Wollongong sites.
- Open Access
- 1 March 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-46
Comment on egusphere-2023-3089
To fight climate change it is crucial to have a precise knowledge of Greenhouse Gas (GHG) concentrations in the atmosphere and to monitor sources and sinks of GHGs. On global scales, satellites are an appropriate monitoring tool. For the validation of the satellite measurements, and to tie them to the World Meteorological Organization (WMO) trace gas scale, ground based Fourier Transform Infrared (FTIR) networks are used, which provide reference data. To ensure the highest quality validation data, the network must be scaled to the WMO trace gas scale and have a very small site-to-site bias. Currently, the Total Carbon Column Observing Network (TCCON) is the de-facto standard FTIR network for providing reference data. To ensure a small site-to-site bias is a major challenge for the TCCON. In this work we describe the development and application of a new method to evaluate the site-to-site bias by using a remotely controlled portable FTIR spectrometer as a Travel Standard (TS) for evaluating the consistency of columnar GHG measurements performed at different TCCON stations and we describe campaign results for the TCCON sites in Tsukuba (Japan), East Trout Lake (Canada) and Wollongong (Australia). The TS is based on a characterized portable EM27/SUN FTIR spectrometer equipped with an accurate pressure sensor which is operated in an automated enclosure. The EM27/SUN is the standard instrument of the Collaborative Carbon Column Observing Network (COCCON). The COCCON is designed such that all spectrometers are referenced to a common reference unit located in Karlsruhe, Germany. To evaluate the long-term stability of the TS instrument, it is placed side-by-side with the TCCON instrument in Karlsruhe and the COCCON reference unit (the EM27/SUN spectrometer SN37, which is operated permanently next to the TCCON-KA site) between deployments to collect comparing measurements. At each of the visited TCCON sites, the TCCON spectrometers collected low-resolution (LR) (0.5 cm-1) and high-resolution (HR) (0.02 cm-1) measurements in an alternating manner. In East Trout Lake (ETL), the TCCON spectrometer broke down while the TS was en route to the station. Hence, no side-by-side comparison was possible there. For Tsukuba and Wollongong the agreement found for XCO2 is on the 0.1 % level. For XCH4 the agreement is at the 0.2 % level, with the low-resolution measurements showing a low bias at both sites and for both gases. For XCO the deviations are up to 7 %. The reason for this is likely to be an known issue with the CO a priori profiles used by TCCON over source regions. The pressure analysis reveals excellent agreement (0.027 hPa, 0.135 hPa, and 0.094 hPa) for the Tsukuba, ETL, and Wollongong sites.
- 1 March 2024
- Published by Copernicus GmbH
- Vol. 2024, 1-46
Open AccessComment on egusphere-2023-3089
To fight climate change it is crucial to have a precise knowledge of Greenhouse Gas (GHG) concentrations in the atmosphere and to monitor sources and sinks of GHGs. On global scales, satellites are an appropriate monitoring tool. For the validation of the satellite measurements, and to tie them to the World Meteorological Organization (WMO) trace gas scale, ground based Fourier Transform Infrared (FTIR) networks are used, which provide reference data. To ensure the highest quality validation data, the network must be scaled to the WMO trace gas scale and have a very small site-to-site bias. Currently, the Total Carbon Column Observing Network (TCCON) is the de-facto standard FTIR network for providing reference data. To ensure a small site-to-site bias is a major challenge for the TCCON. In this work we describe the development and application of a new method to evaluate the site-to-site bias by using a remotely controlled portable FTIR spectrometer as a Travel Standard (TS) for evaluating the consistency of columnar GHG measurements performed at different TCCON stations and we describe campaign results for the TCCON sites in Tsukuba (Japan), East Trout Lake (Canada) and Wollongong (Australia). The TS is based on a characterized portable EM27/SUN FTIR spectrometer equipped with an accurate pressure sensor which is operated in an automated enclosure. The EM27/SUN is the standard instrument of the Collaborative Carbon Column Observing Network (COCCON). The COCCON is designed such that all spectrometers are referenced to a common reference unit located in Karlsruhe, Germany. To evaluate the long-term stability of the TS instrument, it is placed side-by-side with the TCCON instrument in Karlsruhe and the COCCON reference unit (the EM27/SUN spectrometer SN37, which is operated permanently next to the TCCON-KA site) between deployments to collect comparing measurements. At each of the visited TCCON sites, the TCCON spectrometers collected low-resolution (LR) (0.5 cm-1) and high-resolution (HR) (0.02 cm-1) measurements in an alternating manner. In East Trout Lake (ETL), the TCCON spectrometer broke down while the TS was en route to the station. Hence, no side-by-side comparison was possible there. For Tsukuba and Wollongong the agreement found for XCO2 is on the 0.1 % level. For XCH4 the agreement is at the 0.2 % level, with the low-resolution measurements showing a low bias at both sites and for both gases. For XCO the deviations are up to 7 %. The reason for this is likely to be an known issue with the CO a priori profiles used by TCCON over source regions. The pressure analysis reveals excellent agreement (0.027 hPa, 0.135 hPa, and 0.094 hPa) for the Tsukuba, ETL, and Wollongong sites.
- Open Access
- 2 February 2024
- Published by Copernicus GmbH in EGUsphere
- Vol. 2024, 1-46
Using a portable FTIR spectrometer to evaluate the consistency of TCCON measurements on a global scale: The COCCON Travel Standard
To fight climate change it is crucial to have a precise knowledge of Greenhouse Gas (GHG) concentrations in the atmosphere and to monitor sources and sinks of GHGs. On global scales, satellites are an appropriate monitoring tool. For the validation of the satellite measurements, and to tie them to the World Meteorological Organization (WMO) trace gas scale, ground based Fourier Transform Infrared (FTIR) networks are used, which provide reference data. To ensure the highest quality validation data, the network must be scaled to the WMO trace gas scale and have a very small site-to-site bias. Currently, the Total Carbon Column Observing Network (TCCON) is the de-facto standard FTIR network for providing reference data. To ensure a small site-to-site bias is a major challenge for the TCCON. In this work we describe the development and application of a new method to evaluate the site-to-site bias by using a remotely controlled portable FTIR spectrometer as a Travel Standard (TS) for evaluating the consistency of columnar GHG measurements performed at different TCCON stations and we describe campaign results for the TCCON sites in Tsukuba (Japan), East Trout Lake (Canada) and Wollongong (Australia). The TS is based on a characterized portable EM27/SUN FTIR spectrometer equipped with an accurate pressure sensor which is operated in an automated enclosure. The EM27/SUN is the standard instrument of the Collaborative Carbon Column Observing Network (COCCON). The COCCON is designed such that all spectrometers are referenced to a common reference unit located in Karlsruhe, Germany. To evaluate the long-term stability of the TS instrument, it is placed side-by-side with the TCCON instrument in Karlsruhe and the COCCON reference unit (the EM27/SUN spectrometer SN37, which is operated permanently next to the TCCON-KA site) between deployments to collect comparing measurements. At each of the visited TCCON sites, the TCCON spectrometers collected low-resolution (LR) (0.5 cm-1) and high-resolution (HR) (0.02 cm-1) measurements in an alternating manner. In East Trout Lake (ETL), the TCCON spectrometer broke down while the TS was en route to the station. Hence, no side-by-side comparison was possible there. For Tsukuba and Wollongong the agreement found for XCO2 is on the 0.1 % level. For XCH4 the agreement is at the 0.2 % level, with the low-resolution measurements showing a low bias at both sites and for both gases. For XCO the deviations are up to 7 %. The reason for this is likely to be an known issue with the CO a priori profiles used by TCCON over source regions. The pressure analysis reveals excellent agreement (0.027 hPa, 0.135 hPa, and 0.094 hPa) for the Tsukuba, ETL, and Wollongong sites.
- 2 February 2024
- Published by Copernicus GmbH in EGUsphere
- Vol. 2024, 1-46
Open AccessUsing a portable FTIR spectrometer to evaluate the consistency of TCCON measurements on a global scale: The COCCON Travel Standard
To fight climate change it is crucial to have a precise knowledge of Greenhouse Gas (GHG) concentrations in the atmosphere and to monitor sources and sinks of GHGs. On global scales, satellites are an appropriate monitoring tool. For the validation of the satellite measurements, and to tie them to the World Meteorological Organization (WMO) trace gas scale, ground based Fourier Transform Infrared (FTIR) networks are used, which provide reference data. To ensure the highest quality validation data, the network must be scaled to the WMO trace gas scale and have a very small site-to-site bias. Currently, the Total Carbon Column Observing Network (TCCON) is the de-facto standard FTIR network for providing reference data. To ensure a small site-to-site bias is a major challenge for the TCCON. In this work we describe the development and application of a new method to evaluate the site-to-site bias by using a remotely controlled portable FTIR spectrometer as a Travel Standard (TS) for evaluating the consistency of columnar GHG measurements performed at different TCCON stations and we describe campaign results for the TCCON sites in Tsukuba (Japan), East Trout Lake (Canada) and Wollongong (Australia). The TS is based on a characterized portable EM27/SUN FTIR spectrometer equipped with an accurate pressure sensor which is operated in an automated enclosure. The EM27/SUN is the standard instrument of the Collaborative Carbon Column Observing Network (COCCON). The COCCON is designed such that all spectrometers are referenced to a common reference unit located in Karlsruhe, Germany. To evaluate the long-term stability of the TS instrument, it is placed side-by-side with the TCCON instrument in Karlsruhe and the COCCON reference unit (the EM27/SUN spectrometer SN37, which is operated permanently next to the TCCON-KA site) between deployments to collect comparing measurements. At each of the visited TCCON sites, the TCCON spectrometers collected low-resolution (LR) (0.5 cm-1) and high-resolution (HR) (0.02 cm-1) measurements in an alternating manner. In East Trout Lake (ETL), the TCCON spectrometer broke down while the TS was en route to the station. Hence, no side-by-side comparison was possible there. For Tsukuba and Wollongong the agreement found for XCO2 is on the 0.1 % level. For XCH4 the agreement is at the 0.2 % level, with the low-resolution measurements showing a low bias at both sites and for both gases. For XCO the deviations are up to 7 %. The reason for this is likely to be an known issue with the CO a priori profiles used by TCCON over source regions. The pressure analysis reveals excellent agreement (0.027 hPa, 0.135 hPa, and 0.094 hPa) for the Tsukuba, ETL, and Wollongong sites.
- Open Access
- 25 January 2024
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 58 (5) , 2271-2281
Ground-Based Mobile Measurements to Track Urban Methane Emissions from Natural Gas in 12 Cities across Eight Countries
To mitigate methane emission from urban natural gas distribution systems, it is crucial to understand local leak rates and occurrence rates. To explore urban methane emissions in cities outside the U.S., where significant emissions were found previously, mobile measurements were performed in 12 cities across eight countries. The surveyed cities range from medium size, like Groningen, NL, to large size, like Toronto, CA, and London, UK. Furthermore, this survey spanned across European regions from Barcelona, ES, to Bucharest, RO. The joint analysis of all data allows us to focus on general emission behavior for cities with different infrastructure and environmental conditions. We find that all cities have a spectrum of small, medium, and large methane sources in their domain. The emission rates found follow a heavy-tailed distribution, and the top 10% of emitters account for 60-80% of total emissions, which implies that strategic repair planning could help reduce emissions quickly. Furthermore, we compare our findings with inventory estimates for urban natural gas-related methane emissions from this sector in Europe. While cities with larger reported emissions were found to generally also have larger observed emissions, we find clear discrepancies between observation-based and inventory-based emission estimates for our 12 cities.
- 25 January 2024
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 58 (5) , 2271-2281
Open AccessGround-Based Mobile Measurements to Track Urban Methane Emissions from Natural Gas in 12 Cities across Eight Countries
To mitigate methane emission from urban natural gas distribution systems, it is crucial to understand local leak rates and occurrence rates. To explore urban methane emissions in cities outside the U.S., where significant emissions were found previously, mobile measurements were performed in 12 cities across eight countries. The surveyed cities range from medium size, like Groningen, NL, to large size, like Toronto, CA, and London, UK. Furthermore, this survey spanned across European regions from Barcelona, ES, to Bucharest, RO. The joint analysis of all data allows us to focus on general emission behavior for cities with different infrastructure and environmental conditions. We find that all cities have a spectrum of small, medium, and large methane sources in their domain. The emission rates found follow a heavy-tailed distribution, and the top 10% of emitters account for 60-80% of total emissions, which implies that strategic repair planning could help reduce emissions quickly. Furthermore, we compare our findings with inventory estimates for urban natural gas-related methane emissions from this sector in Europe. While cities with larger reported emissions were found to generally also have larger observed emissions, we find clear discrepancies between observation-based and inventory-based emission estimates for our 12 cities.