MDMartin Dahan

Martin Dahan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Martin Dahan has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • EUS-guided biliary drainage with electrocautery-enhanced lumen-apposing metal stent placement should replace PTBD after ERCP failure in patients with distal tumoral biliary obstruction: a large real-life study

    by C. Ginestet, F. Sanglier, V. Hummel, A. Rouchaud, R. Legros, H. Lepetit, M. Dahan, P. Carrier, V. Loustaud-Ratti, D. Sautereau, et al.

    Aims In cases of malignant distal biliary obstruction, ERCP is the preferred technique for bile duct drainage. In case of failure, the alternative techniques are percutaneous transhepatic biliary drainage (PTBD) and more recently endoscopic ultrasound-guided biliary drainage. A new type of stent called the electrocautery-enhanced lumen-apposing metal stent (EC-LAMS) has been developed to enable the performance of biliary-enteric anastomosis under EUS-guidance in a single step, without prior bile duct puncture or the need for a guidewire. The aim of our study was to compare the real-life efficacies of PTBD and EUS-BD with the EC-LAMS for cases of ERCP failure in patients with malignant biliary obstruction. Methods We performed a monocentric retrospective study comparing PTBD and EUS-BD with the use of electrocautery-enhanced lumen-apposing metal stent in the context of a malignant distal biliary obstruction after ERCP failure. Results 95 patients were included (50 in EUS-BD group and 45 in PTBD group). The main etiology of malignant obstruction was adenocarcinoma of the head of pancreas (85%). There was a significant difference in favor of endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced lumen-apposing metal stent for the following criteria: clinical success: 89.3% vs. 45.5%; p < 0.0001; procedure-related adverse event rate: 2.12% vs. 22.7%; p = 0.003; duration of post-drainage hospitalization: 3.5 vs. 8.2 days; p < 0.0001, overall survival (median survival): 118.2 vs. 42 days; p = 0.012, overall cost of the strategy per patient: 5098 vs. 9363 euros; p < 0.001. Conclusion Our results are in favor of EUS-BD using electrocautery-enhanced lumen-apposing metal stent in case of ERCP failure for a distal tumor biliary obstruction. Operators performing ERCP for distal tumor biliary obstruction must learn this backup procedure because of its superiority over percutaneous transhepatic biliary drainage in terms of clinical success, safety, cost, and overall survival.


  • Effect of implementing a regional referral network on surgical referral rate of benign polyps found during a colorectal cancer screening program: A population-based study

    by Rébecca Rodrigues, Sophie Geyl, Jérémie Albouys, Christelle De Carvalho, Mickael Crespi, Tessa Tabouret, Abdelkader Taibi, Sylvaine Durand-Fontanier, Romain Legros, Martin Dahan, et al.


  • Double-clip traction could be superior to the pocket-creation method with cylindrical cap for colonic ESD: a randomized study in an ex vivo model

    by Jérémie Albouys, Martin Dahan, Hugo Lepetit, Aurélie Charissoux, Anne Guyot, Mathieu Pioche, Romain Legros, Paul Carrier, Véronique Loustaud-Ratti, Sophie Geyl, et al.

    Introduction In Western countries, debates between ESD vs piece-meal EMR as the best treatment for large colorectal adenomas persist regarding the difficulty of ESD the colon, and the safety and relatively good results of piece-meal endoscopic mucosal resection (EMR). Pocket-creation method (PCM) and double-clip countertraction (DCT) are two strategies recently published to facilitate ESD in this challenging situation. Method This is a randomized animal study to compare PCM and DCT strategies for colonic ESD on ex vivo models (bovine colon) performed by 3 operators novice in ESD. Hybridknife type T was used to inject normal saline tinted with a small amount of blue dye in all procedures. Randomization was stratified according to the use of gravity assist. Primary endpoint was the difference in resection speed between PCM and DCT strategies. Results Resection speed was significantly higher in the DCT group than in the PCM group (56.3 vs. 31.6 mm2/min, p = 0.01). Technical success rate, defined as en bloc resection in under 60 min, was significantly better in the DCT group than in the PCM group (100% vs. 84.4%, p = 0.024), perforation rate was lower (0% vs. 18.8%, p = 0.012), and difficulty score was better (2.4 vs. 6.2, p < 0.0001) as was procedure duration (24.2 vs. 40.2 min, p < 0.0001). Conclusion DCT was superior to PCM for ESD in our validated bovine colon model. This strategy is inexpensive, easy to use and adaptive. It might facilitate the widespread use of colonic ESD in Western countries and change Western ideas regarding the use of colonic ESD compared with piece-meal EMR for large benign lesions.


  • Reply to Matsushita et al.

    by Martin Dahan, Anne Guyot, Aurelie Charissoux, Marion Schaefer, Romain Legros, Mathieu Pioche, Jérémie Jacques

    We thank Matsushita et al. for their comment on our report of a giant lymphangioma of the esophagus [1]. They believed that endoscopic submucosal dissection (ESD) is too invasive and risky for the resection of such a benign lesion. As an alternative, they proposed an unroofing technique, which is reportedly safe for treating lymphangioma of the gastrointestinal tract. We wish to emphasize several issues that motivated us to perform ESD. First, we were unaware of the diagnosis before performing resection. Despite a literature review and considerable discussion among the members of the multidisciplinary team, no clear diagnosis could be made before resection of the 15-cm submucosal lesion, which was causing dysphagia. A benign lesion was strongly suspected, but the multidisciplinary team requested endoscopic resection with carcinologic quality criteria for this 56-year-old female patient; only ESD can provide this. Second, the unroofing procedure, which is typically performed once a diagnosis has been established, has been reported only for lymphangioma of the colon [2]. By contrast, even in cases of misdiagnosis or difficult-to-treat recurrence, laparoscopic surgery is an easy, safe, and effective rescue procedure. To date, only 30 cases of esophageal lymphangioma have been reported [3], and those that were larger than 2.5 cm were treated by morbid surgery. Third, because of the lesion size (15 cm), it is unclear whether a simple unroofing procedure would have completely removed the lesion. Finally, Matsushita et al. argued that ESD has a risk of morbidity. However, our team has considerable expertise in ESD, and we developed the effective and safe tunnel plus clip strategy for esophageal ESD [4]. Submucosal tunnelling ensures that a submucosal plan can be found beneath the lesion. Moreover, clip and line traction after tunnel creation facilitates exposure of the lateral submucosal fibers, enabling safe resection. In this rare situation, ESD was, for us, the optimal procedure for diagnostic confirmation and treatment.

  • Endoscopic submucosal dissection as a diagnostic procedure for a giant submucosal “sausage” causing dysphagia

    by Martin Dahan, Anne Guyot, Aurelie Charissoux, Marion Schaefer, Romain Legros, Mathieu Pioche, Jérémie Jacques

    A 56-year-old woman was referred to our endoscopy unit for severe dysphagia with weight loss. A large sessile submucosal lesion was discovered during gastroscopy at 25 – 40 cm from the dental arches. Endoscopic ultrasonography (EUS) revealed a submucosal lesion not invading the muscular layer with a cystic component. The findings of EUS-guided fine needle aspiration (EUS-FNA) were inconclusive. Computed tomography (CT) confirmed a large hypodense lesion obstructing the middle and lower third of the esophagus ([Fig. 1]). Therefore, we chose a diagnostic endoscopic submucosal dissection (ESD) to avoid morbid surgery for a potentially benign lesion. First, a proximal incision was made to create a tunnel using a T-type HybridKnife (Erbe Elektromedizin, Tübingen, Germany) after glycerol solution had been injected. Distal incision was not performed so that we could close the tunnel to avoid complications should the resection fail. Distal progression with the tunneling technique was difficult so we made lateral incisions and applied the clip-with-line traction technique. An IT-Knife (Olympus, France) was finally used for distal incision because of constraints owing to specimen size. The resection was en bloc, but the specimen fell into the stomach. We fragmented the lesion with a 25-mm hot snare (Olympus) and extracted the pieces with a basket snare (US Endoscopy). The resection site was clean ([Video 1]). Video 1 Endoscopic submucosal dissection of a giant cystic lymphangioma in the esophagus. Histopathological analysis revealed a giant cystic lymphangioma ([Fig. 2]). The patient remained well 5 months later, with no residual dysphagia, and a follow-up gastroscopy was normal. Esophageal lymphangiomas are very rare, with around 30 reported cases. Endoscopic resection has been proposed when the diagnosis is in doubt or to treat the symptoms for lesions smaller than 2.5 cm [1] [2] [3]. Until now, larger lesions have been treated by radical surgery. We suggest ESD as a diagnostic and therapeutic procedure for these submucosal lesions. Should the procedure fail, any additional surgery will not have been compromised by this minimally invasive procedure. Endoscopy_UCTN_Code_TTT_1AO_2AC